A New Compensation Method for Measurement of Thread Pitch Diameter by Profile Scanning
, and
Dec 15, 2014
About this article
Published Online: Dec 15, 2014
Page range: 323 - 330
Received: Mar 31, 2014
Accepted: Oct 24, 2014
DOI: https://doi.org/10.2478/msr-2014-0044
Keywords
© 2014 Chen Sheng et. al.
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
For measurement of existing thread parameters using profile scanning, system error increases as pitch diameter, difference between the calibrating thread and measuring thread increases with the single gauge calibration method. There are several alignment deviations affecting the measurement of pitch diameter. To reduce the system error, a compensation method using two standard thread gauges to calculate the alignment deviations is proposed here. Finally, the theoretical and experimental comparisons between the single gauge calibration method and the proposed method are presented. The results demonstrate that the two gauges calibration method can effectively reduce the system error.