Ozone disinfection efficiency against airborne microorganisms in hospital environment: a case study

Published Online: 07 Jan 2023
Volume & Issue: Volume 73 (2022) - Issue 4 (December 2022)
Page range: 270 - 276
Received: 01 Apr 2022
Accepted: 01 Dec 2022
Journal Details
License
Format
Journal
eISSN
1848-6312
First Published
26 Mar 2007
Publication timeframe
4 times per year
Languages
English

Hospital air contamination with microorganisms, multidrug-resistant in particular (15), has received more attention since the COVID-19 pandemic, as microorganisms can spread through the air on aerosol particles or liquid droplets (6, 7). These particles can be suspended in the air for over a week (7) and can settle on surfaces (8, 9). One of preventive measures against hospital acquired infections include ambient disinfection of hospital rooms (2, 5, 10–12), but they may not be efficient enough against antibiotic-resistant microorganisms, especially in a biofilm (2, 13–16). Furthermore, conventional disinfectants are often toxic and a burden in terms of hazardous waste.

In this respect, gaseous disinfectants stand out as the best choice for air disinfection (4, 10, 17), and ozone has already proven its antimicrobial effects through oxidation of nucleic acids, glycolipids, glycoproteins, sulphhydryl groups, enzyme amino acids, peptides, and proteins (18, 19). Although it is widely used in water disinfection or waste management, its use in hospital and similar environments is relatively rare and limited to disinfection of hospital linen and eradication of methicillin-resistant Staphylococcus aureus (20, 21). It was only since the COVID-19 pandemic that air disinfection in hospitals received more attention, as it was reported that ozone was successful against SARS-CoV-2 and other microorganisms on various surfaces (22, 23) and to have a potential use in “no-touch” automated room disinfection systems (24). In addition, ozone is very cheap to produce.

However, save for a few studies (25), knowledge about its efficacy against airborne contamination in hospital settings is still scarce. The aim of this study was to gain more insight into its efficiency by determining air quality in a hospital room in terms of bacterial and mould load before and after treatment with ozone.

Materials and methods
Air sampling

Air was sampled in July in a recovery room for postoperative treatment located in the new wing of the Dr Ivo Pedišić General Hospital in Sisak, Croatia. The room (32.4 m3; 4×3×2.7 m) was furnished with a stretcher, sink, desk, chair and a wardrobe. Ventilation in the room combines natural (windows) and centralised ventilation with a system using HEPA filters. Room temperature and relative humidity when the room is occupied by a patient are 23 °C and around 55 %, respectively. We made sure to have the same room temperature and relative humidity at sampling, so that the conditions are as close to real-life settings as possible.

Before ozone treatment, all ventilation holes in the room were sealed off and the central ventilation system was turned off. Air was sampled twice to get baseline (pre-ozone treatment) and post-ozone treatment measurements at three points (window sill, desk, and sink) (Figure 1) using a mobile, 250 L air sampler (MAS-100, Merck, Berlin, Germany) which aspirates ambient air through a perforated lid. This air impacts the surface of a growth medium in standard size Petri dishes. Adhering microorganisms are then incubated and counted as instructed by the manufacturer.

Figure 1

Recovery room layout

For ozone treatment we used a mobile ozone generator Mozone GPF 8008 (Mozone, Sisak, Croatia) releasing a mixture of air and ozone until ozone reached the concentration of 15.71 mg/m3 in the air. Treatment with this concentration lasted for 1 h at room temperature of 23 °C and relative humidity of 60 %. The distance from the ozone generator and each sampling point was about 1.5 m. Ozone concentration was monitored continuously with a portable ozone detector (Keernuo GT901, Keernuo, Shanghai, China), also placed at 1.5 m from the generator. Room temperature and relative humidity were monitored with an Auriol 4-LD5531 radio-controlled weather station (Auriol, Berlin, Germany). After the ozone treatment was finished and ozone gas dissolved (in approximately 2 h), we took another air measurement for microorganisms. All experiments were done in triplicate on all sampling points.

Determination of total bacterial and mould count

Air was sampled directly on TSA agar (Biolife, Milano, Italy), chromogenic UTI agar (BrillianceTM, Oxoid, Basingstoke, UK), and Saburaud dextrose agar (Biolife, Milano, Italy) for moulds. The chromogenic agar was also used for bacterial identification as described elsewhere (26, 27). Agar plates for bacterial identification were incubated in a BD400 incubator (Binder, Bohemia, NY, USA) at 36 °C for 48 h. Sabouraud dextrose agar plates were incubated at 30 °C for 10 days. After incubation, total bacteria and moulds were counted and expressed as CFU/250 L of air. All counts were done in triplicate.

Bacterial identification

Bacteria grown on the TSA and chromogenic UTI agar were identified by colony morphology and colour according to manufacturer’s instructions. The final identification of the dominant species was done using the standard API20 Staph test (bioMérieux, Marcy-l´Etoile, France), Gram staining, catalase test, coagulase test, and oxidase test as described elsewhere (26, 27).

Data processing and statistical analyses

The total bacterial and mould counts are expressed as CFU/250 L of air, which is the capacity of the sampling device. They are estimates based on statistical corrections according to Feller’s formula (28, 29), as follows:

Pr=N1N + 1NN - 1 + 1N-2 1Nr + 1 $$\begin{equation}P r=N\left(\frac{1}{N}+\frac{1 N}{N}-1+\frac{1}{N-2} \ldots \frac{1}{N r}+1\right)\end{equation}$$

where Pr is the probable (statistical) total number, r the number of colonies counted, and N the number of holes on the device head (N=400).

To evaluate the effect of ozone on the total bacterial and mould counts we relied on nonparametric Wilcoxon rank-sum test and set the significance to p<0.05.

Results and discussion

Ambient disinfection with ozone significantly reduced the total bacterial and mould count at all three sampling points (Table 1, Figure 2). Table 2 and Figure 3 show the identified bacterial cultures and their reduction after ozone treatment. The dominant bacterial strain before and after ozone treatment remained Micrococcus spp. at all three sampling points (Table 2). In contrast, several other authors reported the dominance of Staphylococcus spp. in hospital air (3032).

Figure 2

Total bacterial and mould counts before (BT) and after (AT) 1-hour treatment with ozone at the concentration of 15.71 mg/m3. Different letters denote significant differences between groups (p<0.05; nonparametric Wilcoxon rank-sum test)

Figure 3

Changes in bacterial counts and prevalence (%) by identified genera before (BT) and after (AT) ozone treatment (15.71 mg/m3) at the three sampling points. Different letters denote significant differences between groups (p<0.05; nonparametric Wilcoxon rank-sum test).

Inhibition rates of total bacteria counts at the three sampling points

Sampling pointBefore treatment ozone
After treatment ozone
Inhibition (%)
rPrrPr
L1 – sink
413
2986
276
467
33
L2 – desk
367
992
151
189
58
L3 – window sill30959111814061

Pr – probable (statistical) total bacterial count; r – number of counted colonies

Inhibition rates by identified bacteria at the three sampling points.

Bacteria by identified generaSink
Desk
Window sill
Before ozone treatment
After ozone treatment
Inhibition (%)
Before ozone treatment
After ozone treatment
Inhibition (%)
Before ozone treatment
After ozone treatment
Inhibition (%)
rPrrPr rPrrPr rPrrPr
Micrococcus spp.
380
1189
260
419
31
345
791
141
174
59
275
464
105
122
61
Staphylococcus spp.
15
15
10
10
33
2
2
2
2
0
4
4
4
4
0
Bacillus spp.
13
13
4
4
69
10
10
3
3
70
20
20
0
0
100
Acinetobacter spp.5522601010555010109910

Pr – probable (statistical) total bacterial count; r – number of counted colonies

Although we did not identify individual moulds, judging by the morphological properties of grown colonies, Mucor spp. seems to be one of the dominant species, which is in line with the findings of Ziaee et al. (33). Other authors reported the dominance of Aspergillus spp. and Penicillium spp. in the total fungal biomass (30, 34). Of course, our characterisation should be taken with reserve, as only further fungal identification would provide a more specific insight. In the meantime, one possible reason for the inconsistency between our bacterial and fungal findings and those of other studies could be that our measurements took place in a recovery room of a relatively new hospital wing that had been operational for three months only and had received no more than 20 patients by the time of our study.

The efficiency of ozone treatment was not even across the three sampling points but was the most efficient at the window sill (Table 1). This points to an unequal distribution of ozone gas across the room, which is required for an even effect, as reported by Blanco et al. (35) and Ito Kazuhide (36). However, considering that the ozone generator was placed at equal distance from all three sampling points, we believe that this difference may be owed to the fact that its exhaust was directed towards the window.

Furthermore, ozone treatment did not affect all identified bacterial strains equally. Bacillus spp. turned out to be the most sensitive to ozone at all three sampling points, which is a very interesting finding, considering that Bacillus spp. sporulates when exposed to unfavourable environmental conditions, disinfection included (37). It seems that only the vegetative / cultivable forms of Bacillus spp. were present in the room, as ozone is very effective against vegetative bacteria and inhibits sporulation. However this has been reported at very high ozone concentrations which are not adapted to healthcare settings (3739). Staphylococcus spp. turned out to be very resistant, which is also surprising, considering that Russell et al. (16) found Gram-positive cocci to be more sensitive to disinfectants (16). However, our results are in line with reports claiming that Gram-positive bacteria are less sensitive to gaseous ozone than the Gram-negative ones (40).

Overall, our findings confirm high ozone efficacy against airborne bacteria in hospital settings reported earlier (25). However, its application as ambient disinfectant has certain limitations, as ozone gas it toxic to humans and can affect the respiratory system (41). The Croatian standards limit its concentration to 0.39 mg/m3 over no more than 8 h a day (42). Furthermore, it has a specific and strong odour and can be corrosive if used very frequently (24). Some of these issues can be resolved with personal protective equipment when applying ozone and by neutralising (quenching) it with agents like magnesium thiosulphate to remove it from air (43).

Conclusion

To sum up, ozone gas at the applied concentration and exposure time reduced bacterial and mould contamination of the recovery room air but did not remove their presence entirely. To achieve effective air hygiene in the hospital environment it is necessary to combine mechanical cleaning of surfaces, conventional disinfectants, regular ventilation, and ozone for final disinfection. Considering the lack of national standards for microbiological indoor air quality, studies like this one provide some insight into the issue and alternative solutions. Further investigation should involve longer exposure time and higher ozone concentrations to get to know better its effects against airborne microorganisms in a hospital environment.

Figure 1

Recovery room layout
Recovery room layout

Figure 2

Total bacterial and mould counts before (BT) and after (AT) 1-hour treatment with ozone at the concentration of 15.71 mg/m3. Different letters denote significant differences between groups (p<0.05; nonparametric Wilcoxon rank-sum test)
Total bacterial and mould counts before (BT) and after (AT) 1-hour treatment with ozone at the concentration of 15.71 mg/m3. Different letters denote significant differences between groups (p<0.05; nonparametric Wilcoxon rank-sum test)

Figure 3

Changes in bacterial counts and prevalence (%) by identified genera before (BT) and after (AT) ozone treatment (15.71 mg/m3) at the three sampling points. Different letters denote significant differences between groups (p<0.05; nonparametric Wilcoxon rank-sum test).
Changes in bacterial counts and prevalence (%) by identified genera before (BT) and after (AT) ozone treatment (15.71 mg/m3) at the three sampling points. Different letters denote significant differences between groups (p<0.05; nonparametric Wilcoxon rank-sum test).

Inhibition rates of total bacteria counts at the three sampling points

Sampling point Before treatment ozone
After treatment ozone
Inhibition (%)
r Pr r Pr
L1 – sink
413
2986
276
467
33
L2 – desk
367
992
151
189
58
L3 – window sill 309 591 118 140 61

Inhibition rates by identified bacteria at the three sampling points.

Bacteria by identified genera Sink
Desk
Window sill
Before ozone treatment
After ozone treatment
Inhibition (%)
Before ozone treatment
After ozone treatment
Inhibition (%)
Before ozone treatment
After ozone treatment
Inhibition (%)
r Pr r Pr r Pr r Pr r Pr r Pr
Micrococcus spp.
380
1189
260
419
31
345
791
141
174
59
275
464
105
122
61
Staphylococcus spp.
15
15
10
10
33
2
2
2
2
0
4
4
4
4
0
Bacillus spp.
13
13
4
4
69
10
10
3
3
70
20
20
0
0
100
Acinetobacter spp. 5 5 2 2 60 10 10 5 5 50 10 10 9 9 10

Scott E, Bloomfield SF. The survival and transfer of microbial contamination via cloths, hands and utensils. J Appl Bacteriol 1990;68:271–8. doi: 10.1111/j.1365-2672.1990.tb02574.x Scott E Bloomfield SF The survival and transfer of microbial contamination via cloths, hands and utensils J Appl Bacteriol 199068271 8 10.1111/j.1365-2672.1990.tb02574.x2111304Open DOISearch in Google Scholar

Costa DM, Johani K, Melo DS, Lopes LKO, Lopes Lima LKO, Tipple AFV, Hu H, Vickery K. Biofilm contamination of high-touched surfaces in intensive care units: epidemiology and potential impacts. Lett Appl Microbiol 2019;68:269–76. doi: 10.1111/lam.13127 Costa DM Johani K Melo DS Lopes LKO Lopes Lima LKO Tipple AFV Hu H Vickery K Biofilm contamination of high-touched surfaces in intensive care units: epidemiology and potential impacts Lett Appl Microbiol 201968269 76 10.1111/lam.1312730758060Open DOISearch in Google Scholar

Davies A, Pottage T, Bennett A, Walker J. Gaseous and air decontamination technologies for Clostridium difficile in the healthcare environment. J Hosp Infect 2011;77:199–203. doi: 10.1016/j. jhin.2010.08.012 Davies A Pottage T Bennett A Walker J Gaseous and air decontamination technologies for Clostridium difficile in the healthcare environment J Hosp Infect 201177199 203 10.1016/j. jhin.2010.08.012Open DOISearch in Google Scholar

Marra AR, Schweizer ML, Edmond MB. No-touch disinfection methods to decrease multidrug-resistant organism infections: A systematic review and meta-analysis. Infect Control Hosp Epidemiol 2018;39:20–31. doi: 10.1017/ice.2017.226 Marra AR Schweizer ML Edmond MB No-touch disinfection methods to decrease multidrug-resistant organism infections: A systematic review and meta-analysis Infect Control Hosp Epidemiol 20183920 31 10.1017/ice.2017.22629144223Open DOISearch in Google Scholar

Boyce JM. Environmental contamination makes an important contribution to hospital infection. J Hosp Infect 2007;65(Suppl 2):50–4. doi: 10.1016/S0195-6701(07)60015-2 Boyce JM Environmental contamination makes an important contribution to hospital infection J Hosp Infect 200765Suppl 250 4 10.1016/S0195-6701(07)60015-217540242Open DOISearch in Google Scholar

Fernstrom A, Goldblatt M. Aerobiology and its role in the transmission of infectious diseases. J Pathog 2013;2013:493960. doi: 10.1155/2013/493960 Fernstrom A Goldblatt M Aerobiology and its role in the transmission of infectious diseases J Pathog 20132013493960 10.1155/2013/493960355685423365758Open DOISearch in Google Scholar

Jones RM, Brosseau LM. Aerosol transmission of infectious disease. J O cc up E nv iron Me d 2 0 1 5 ; 5 7 : 5 0 1 – 8 . do i : 1 0 . 1 0 9 7 / JOM.0000000000000448 Jones RM Brosseau LM Aerosol transmission of infectious disease. J O cc up E nv iron Me d 2 0 1 5 ; 5 7 : 5 0 1 – 8 do i : 1 0 . 1 0 9 7 / JOM.0000000000000448Search in Google Scholar

Smith K, Hunter IS. Efficacy of common hospital biocides with biofilms of multi-drug resistant clinical isolates. J Med Microbiol 2008;57:966–73. doi: 10.1099/jmm.0.47668-0 Smith K Hunter IS Efficacy of common hospital biocides with biofilms of multi-drug resistant clinical isolates J Med Microbiol 200857966 73 10.1099/jmm.0.47668-018628497Open DOISearch in Google Scholar

Passaretti CL, Otter JA, Reich NG, Myers J, Shepard J, Ross T, Carroll KC, Lipsett P, Perl TM. An evaluation of environmental decontamination with hydrogen peroxide vapor for reducing the risk of patient acquisition of multidrug-resistant organisms. Clin Infect Dis 2013;56:27–35. doi: 10.1093/cid/cis839 Passaretti CL Otter JA Reich NG Myers J Shepard J Ross T Carroll KC Lipsett P Perl TM An evaluation of environmental decontamination with hydrogen peroxide vapor for reducing the risk of patient acquisition of multidrug-resistant organisms Clin Infect Dis 20135627 35 10.1093/cid/cis83923042972Open DOISearch in Google Scholar

Boyce JM. Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals. Antimicrob Resist Infect Control 2016;5:1–10. doi: 10.1186/s13756-016-0111-x Boyce JM Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals Antimicrob Resist Infect Control 201651 10 10.1186/s13756-016-0111-x482719927069623Open DOISearch in Google Scholar

Talon D. The role of the hospital environment in the epidemiology of multi-resistant bacteria. J Hosp Infect 1999;43:13–7. doi: 10.1053/ jhin.1999.0613 Talon D The role of the hospital environment in the epidemiology of multi-resistant bacteria J Hosp Infect 19994313 7 10.1053/ jhin.1999.0613Open DOISearch in Google Scholar

Mody L, Washer LL, Kaye KS, Gibson K, Saint S, Reyes K, Cassone M, Mantey J, Cao J, Altamimi S, Perri M, Sax H, Chopra V, Zervos M. Multidrug-resistant organisms in hospitals: what is on patient hands and in their rooms? Clin Infect Dis 2019;69:1837–44. doi: 10.1093/cid/ ciz092 Mody L Washer LL Kaye KS Gibson K Saint S Reyes K Cassone M Mantey J Cao J Altamimi S Perri M Sax H Chopra V Zervos M Multidrug-resistant organisms in hospitals: what is on patient hands and in their rooms? Clin Infect Dis 2019691837 44 10.1093/cid/ ciz092Open DOISearch in Google Scholar

Pendleton JN, Gorman SP, Gilmore BF. Clinical relevance of the ESKAPE pathogens. Expert Rev Anti Infect Ther 2013;11:297–308. doi: 10.1586/eri.13.12 Pendleton JN Gorman SP Gilmore BF Clinical relevance of the ESKAPE pathogens Expert Rev Anti Infect Ther 201311297 308 10.1586/eri.13.1223458769Open DOISearch in Google Scholar

Almatroudi A, Gosbell IB, Hu H, Jensen SO, Espedido BA, Tahir S, Glasbey TO, Legge P, Whiteley G, Deva A, Vickery K. Staphylococcus aureus dry-surface biofilms are not killed by sodium hypochlorite: implications for infection control. J Hosp Infect 2016;93:263–70. doi: 10.1016/j.jhin.2016.03.020 Almatroudi A Gosbell IB Hu H Jensen SO Espedido BA Tahir S Glasbey TO Legge P Whiteley G Deva A Vickery K Staphylococcus aureus dry-surface biofilms are not killed by sodium hypochlorite: implications for infection control J Hosp Infect 201693263 70 10.1016/j.jhin.2016.03.02027140421Open DOISearch in Google Scholar

Bridier A, Briandet R, Thomas V, Dubois-Brissonnet F. Biofouling : The Journal of Bioadhesion and Biofilm Resistance of bacterial biofilms to disinfectants : a review. Biofouling J Bioadhesion Biofilm Res 2011;27:1017–32. doi: 10.1080/08927014.2011.626899 Bridier A Briandet R Thomas V Dubois-Brissonnet F Biofouling : The Journal of Bioadhesion and Biofilm Resistance of bacterial biofilms to disinfectants : a review Biofouling J Bioadhesion Biofilm Res 2011271017 32 10.1080/08927014.2011.62689922011093Open DOISearch in Google Scholar

Russell AD. Bacterial resistance to disinfectants: present knowledge and future problems. J Hosp Infect 1999;43(Suppl 1):S57–68. doi: 10.1016/ s0195-6701(99)90066-x Russell AD Bacterial resistance to disinfectants: present knowledge and future problems J Hosp Infect 199943Suppl 1S57 68 10.1016/ s0195-6701(99)90066-xOpen DOISearch in Google Scholar

Weber DJ, Kanamori H, Rutala WA. “No touch” technologies for environmental decontamination: focus on ultraviolet devices and hydrogen peroxide systems. Curr Opin Infect Dis 2016;29:424–31. doi: 10.1097/QCO.0000000000000284 Weber DJ Kanamori H Rutala WA. “No touch” technologies for environmental decontamination: focus on ultraviolet devices and hydrogen peroxide systems. Curr Opin Infect Dis 201629424 31 10.1097/QCO.000000000000028427257798Open DOISearch in Google Scholar

Giuliani G, Ricevuti G, Galoforo A, Franzini M. Microbiological aspects of ozone: bactericidal activity and antibiotic/antimicrobial resistance in bacterial strains treated with ozone. Ozone Ther 2018;3(3):7971. doi: 10.4081/ozone.2018.7971 Giuliani G Ricevuti G Galoforo A Franzini M Microbiological aspects of ozone: bactericidal activity and antibiotic/antimicrobial resistance in bacterial strains treated with ozone Ozone Ther 2018347971 10.4081/ozone.2018.7971Open DOISearch in Google Scholar

Li CS, Wang YC. Surface germicidal effects of ozone for microorganisms. Am Ind Hyg Assoc J 2003;64:533–7. doi: 10.1202/559.1 Li CS Wang YC Surface germicidal effects of ozone for microorganisms Am Ind Hyg Assoc J 200364533 7 10.1202/559.112908871Open DOISearch in Google Scholar

Cardoso ACC, Fiorini JE, Ferriera LR, Gurjao JW, Amaral LA. Disinfection of hospital laundry using ozone : microbiological evaluation. Infect Control Hosp Epidemiol 2011;21:248. doi: 10.1086/503216 Cardoso ACC Fiorini JE Ferriera LR Gurjao JW Amaral LA Disinfection of hospital laundry using ozone : microbiological evaluation Infect Control Hosp Epidemiol 201121248 10.1086/50321610782581Open DOISearch in Google Scholar

de Boer HEL, van Elzelingen-Dekker CM, van Rheenen-Verberg CMF, Spanjaard L. Use of gaseous ozone for eradication of methicillin-resistant Staphylococcus aureus from the home environment of a colonized hospital employee. Infect Control Hosp Epidemiol 2006;27:1120–2. doi: 10.1086/507966 de Boer HEL van Elzelingen-Dekker CM van Rheenen-Verberg CMF Spanjaard L Use of gaseous ozone for eradication of methicillin-resistant Staphylococcus aureus from the home environment of a colonized hospital employee Infect Control Hosp Epidemiol 2006271120 2 10.1086/50796617006820Open DOISearch in Google Scholar

Franke G, Knobling B, Brill FH, Becker B, Klupp EM, Belmar Campos C, Pfefferle S, Lütgehetmann M, Knobloch JK. An automated room disinfection system using ozone is highly active against surrogates for SARS-CoV-2. J Hosp Infect 2021;112:108–13. doi: 10.1016/j. jhin.2021.04.007 Franke G Knobling B Brill FH Becker B Klupp EM Belmar Campos C Pfefferle S Lütgehetmann M Knobloch JK An automated room disinfection system using ozone is highly active against surrogates for SARS-CoV-2 J Hosp Infect 2021112108 13 10.1016/j. jhin.2021.04.007Open DOISearch in Google Scholar

Epelle EI, Macfarlane A, Cusack M, Burns A, Thissera B, Mackay W, Rateb ME, Yaseen M. Bacterial and fungal disinfection via ozonation in air. J Microbiol Methods 2022;194:106431. doi: 10.1016/j. mimet.2022.106431 Epelle EI Macfarlane A Cusack M Burns A Thissera B Mackay W Rateb ME Yaseen M Bacterial and fungal disinfection via ozonation in air J Microbiol Methods 2022194106431 10.1016/j. mimet.2022.106431Open DOISearch in Google Scholar

Otter JA, Yezli S, Perl TM, Barbut F, French GL. The role of “no-touch” automated room disinfection systems in infection prevention and control. J Hosp Infect 2013;83:1–13. doi: 10.1016/j.jhin.2012.10.002 Otter JA Yezli S Perl TM Barbut F French GL The role of “no-touch” automated room disinfection systems in infection prevention and control J Hosp Infect 2013831 13 10.1016/j.jhin.2012.10.00223195691Open DOISearch in Google Scholar

Moccia G, De Caro F, Pironti C, Boccia G, Capunzo M, Borrelli A, Motta O. Development and improvement of an effective method for air and surfaces disinfection with ozone gas as a decontaminating agent. Medicina (Kaunas) 2020;56(11):578. doi: 10.3390/medicina56110578 Moccia G De Caro F Pironti C Boccia G Capunzo M Borrelli A Motta O Development and improvement of an effective method for air and surfaces disinfection with ozone gas as a decontaminating agent Medicina (Kaunas) 20205611578 10.3390/medicina56110578769411333143010Open DOISearch in Google Scholar

Franco-Duarte R, Černáková L, Kadam S, Kaushik KS, Salehi B, Bevilacqua A, Corbo MR, Antolak H, Dybka-Stępień K, Leszczewicz M, Relison Tintino S, Alexandrino de Souza VC, Sharifi-Rad J, Coutinho HDM, Martins N, Rodrigues CF. Advances in chemical and biological methods to identify microorganisms - from past to present. Microorganisms 2019;7(5):130. doi: 10.3390/microorganisms7050130 Franco-Duarte R Černáková L Kadam S Kaushik KS Salehi B Bevilacqua A Corbo MR Antolak H Dybka-Stępień K Leszczewicz M Relison Tintino S Alexandrino de Souza VC Sharifi-Rad J Coutinho HDM Martins N Rodrigues CF Advances in chemical and biological methods to identify microorganisms - from past to present Microorganisms 201975130 10.3390/microorganisms7050130656041831086084Open DOISearch in Google Scholar

Giuliano C, Patel CR, Kale-Pradhan PB. A guide to bacterial culture identification and results interpretation. Pharm Ther 2019;44:192–200. PMCID: PMC6428495 Giuliano C Patel CR Kale-Pradhan PB A guide to bacterial culture identification and results interpretation Pharm Ther 201944192 200 PMCID: PMC6428495Search in Google Scholar

MAS MERCK. Operating Manual MAS-100™ with data-port MAS-100 [displayed 5 December 2022]. Available at https://archive-resources.coleparmer.com/Manual_pdfs/39182-90,-82.pdf MAS MERCK. Operating Manual MAS-100™ with data-port MAS-100 [displayed 5 December 2022]. Available at https://archive-resources.coleparmer.com/Manual_pdfs/39182-90,-82.pdfSearch in Google Scholar

Basińska M, Michałkiewicz M, Ratajczak K. Impact of physical and microbiological parameters on proper indoor air quality in nursery. Environ Int 2019;132:105098. doi: 10.1016/j.envint.2019.105098 Basińska M Michałkiewicz M Ratajczak K Impact of physical and microbiological parameters on proper indoor air quality in nursery Environ Int 2019132105098 10.1016/j.envint.2019.10509831434053Open DOISearch in Google Scholar

Cabo Verde S, Almeida SM, Matos J, Guerreiro D, Meneses M, Faria T, Botelho D, Santos M, Viegas C. Microbiological assessment of indoor air quality at different hospital sites. Res Microbiol 2015;166:557–63. doi: 10.1016/j.resmic.2015.03.004 Cabo Verde S Almeida SM Matos J Guerreiro D Meneses M Faria T Botelho D Santos M Viegas C Microbiological assessment of indoor air quality at different hospital sites Res Microbiol 2015166557 63 10.1016/j.resmic.2015.03.00425869221Open DOISearch in Google Scholar

Kunwar A, Tamrakar S, Poudel S, Sharma S, Parajuli P. Bacteriological assessment of the indoor air of different hospitals of Kathmandu district. Int J Microbiol 2019;2019:5320807. doi: 10.1155/2019/5320807 Kunwar A Tamrakar S Poudel S Sharma S Parajuli P Bacteriological assessment of the indoor air of different hospitals of Kathmandu district Int J Microbiol 201920195320807 10.1155/2019/5320807647602031089326Open DOISearch in Google Scholar

Ling S, Hui L. Evaluation of the complexity of indoor air in hospital wards based on PM2.5, real-time PCR, adenosine triphosphate bioluminescence assay, microbial culture and mass spectrometry. BMC Infect Dis 2019;19(1):646. doi: 10.1186/s12879-019-4249-z Ling S Hui L Evaluation of the complexity of indoor air in hospital wards based on PM2.5, real-time PCR, adenosine triphosphate bioluminescence assay, microbial culture and mass spectrometry BMC Infect Dis 2019191646 10.1186/s12879-019-4249-z664249431324234Open DOISearch in Google Scholar

Ziaee A, Zia M, Bayat M, Hashemi J. Molecular identification of Mucor and Lichtheimia species in pure cultures of Zygomycetes. Jundishapur J Microbiol 2016;9(4):e35237. doi: 10.5812/jjm.35237 Ziaee A Zia M Bayat M Hashemi J Molecular identification of Mucor and Lichtheimia species in pure cultures of Zygomycetes Jundishapur J Microbiol 201694e35237 10.5812/jjm.35237489816727284399Open DOISearch in Google Scholar

Belizario JA, Lopes LG, Pires RH. Fungi in the indoor air of critical hospital areas: a review. Aerobiologia (Bologna) 2021;37:379–94. doi: 10.1007/s10453-021-09706-7 Belizario JA Lopes LG Pires RH Fungi in the indoor air of critical hospital areas: a review Aerobiologia (Bologna) 202137379 94 10.1007/s10453-021-09706-7811962134007098Open DOISearch in Google Scholar

Blanco A, de Borja Ojembarrena F, Clavo B, Negro C. Ozone potential to fight against SAR-COV-2 pandemic: facts and research needs. Environ Sci Pollut Res 2021;28:16517–31. doi: 10.1007/s11356-020-12036-9 Blanco A de Borja Ojembarrena F Clavo B Negro C Ozone potential to fight against SAR-COV-2 pandemic: facts and research needs Environ Sci Pollut Res 20212816517 31 10.1007/s11356-020-12036-9777850033389580Open DOISearch in Google Scholar

Ito K. Experimental and CFD analyses examining ozone distribution in model rooms with laminar and turbulent flow fields. J Asian Archit Build Eng 2007;6:387–94. doi: 10.3130/jaabe.6.387 Ito K Experimental and CFD analyses examining ozone distribution in model rooms with laminar and turbulent flow fields J Asian Archit Build Eng 20076387 94 10.3130/jaabe.6.387Open DOISearch in Google Scholar

Aydogan A, Gurol MD. Application of gaseous ozone for inactivation of Bacillus subtilis spores. J Air Waste Manag Assoc 2006;56:179–85. doi: 10.1080/10473289.2006.10464443 Aydogan A Gurol MD Application of gaseous ozone for inactivation of Bacillus subtilis spores J Air Waste Manag Assoc 200656179 85 10.1080/10473289.2006.1046444316568801Open DOISearch in Google Scholar

Wood JP, Wendling M, Richter W, Rogers J. The use of ozone gas for the inactivation of Bacillus anthracis and Bacillus subtilis spores on building materials. PLoS One 2020;15(5):e0233291. doi: 10.1371/journal. pone.0233291 Wood JP Wendling M Richter W Rogers J The use of ozone gas for the inactivation of Bacillus anthracis and Bacillus subtilis spores on building materials PLoS One 2020155e0233291 10.1371/journal. pone.0233291Open DOISearch in Google Scholar

Ishizaki K, Shinriki N, Matsuyama H. Inactivation of Bacillus spores by gaseous ozone. J Appl Bacteriol 1986;60:67–72. doi: 10.1111/j.1365-2672.1986.tb01067.x Ishizaki K Shinriki N Matsuyama H Inactivation of Bacillus spores by gaseous ozone J Appl Bacteriol 19866067 72 10.1111/j.1365-2672.1986.tb01067.x3082844Open DOISearch in Google Scholar

Moore G, Griffith C, Peters A. Bactericidal properties of ozone and its potential application as a terminal disinfectant. J Food Prot 2000;63:1100–6. doi: 10.4315/0362-028x-63.8.1100 Moore G Griffith C Peters A Bactericidal properties of ozone and its potential application as a terminal disinfectant J Food Prot 2000631100 6 10.4315/0362-028x-63.8.110010945587Open DOISearch in Google Scholar

Piletić K, Kovač B, Perčić M, Žigon J, Broznić D, Karleuša L, Lučić Blagojević S, Oder M, Gobin I. Disinfecting action of gaseous ozone on OXA-48-producing Klebsiella pneumoniae biofilm in vitro. Int J Environ Res Public Health 2022;19(10):6177. doi: 10.3390/ijerph19106177 Piletić K Kovač B Perčić M Žigon J Broznić D Karleuša L Lučić Blagojević S Oder M Gobin I Disinfecting action of gaseous ozone on OXA-48-producing Klebsiella pneumoniae biofilm in vitro Int J Environ Res Public Health 202219106177 10.3390/ijerph19106177914070235627712Open DOISearch in Google Scholar

Pravilnik o zaštiti radnika od izloženosti opasnim kemikalijama na radu, graničnim vrijednostima izloženosti i biološkim graničnim vrijednostima [Ordinance on the protection of workers of exposure to dangerous chemicals at work, exposure limit values and biological limit values, in Croatian]. Narodne novine 91/2018. Pravilnik o zaštiti radnika od izloženosti opasnim kemikalijama na radu, graničnim vrijednostima izloženosti i biološkim graničnim vrijednostima [Ordinance on the protection of workers of exposure to dangerous chemicals at work, exposure limit values and biological limit values, in Croatian] Narodne novine 912018Search in Google Scholar

Moat J, Cargill J, Shone J, Upton M. Application of a novel decontamination process using gaseous ozone. Can J Microbiol 2009;55:928–33. doi: 10.1139/w09-046 Moat J Cargill J Shone J Upton M Application of a novel decontamination process using gaseous ozone Can J Microbiol 200955928 33 10.1139/w09-04619898532Open DOISearch in Google Scholar

Recommended articles from Trend MD