This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Klote, J.H., Milke, J.A., Turnbull, P.G., Kashef, A., Ferreira, M.J. (2012). Handbook of Smoke Control Engineering. ASHRAE, Atlanta, GA.KloteJ.H.MilkeJ.A.TurnbullP.G.KashefA.FerreiraM.J. (2012). . ASHRAE, Atlanta, GA.Search in Google Scholar
Mowrer, F.W. (2009). Driving forces for smoke movement and management. Fire Technology 45, 147–162.MowrerF.W. (2009). Driving forces for smoke movement and management. 45, 147–162.10.1007/s10694-008-0077-1Search in Google Scholar
Król, M., Król, A. (2017). Wind influence on a building with the natural smoke removal system. Architecture Civil Engineering Environment 3(10), 119–126.KrólM.KrólA. (2017). Wind influence on a building with the natural smoke removal system. 3(10), 119–126.10.21307/acee-2017-042Search in Google Scholar
McGrattan, K. Hostikka, S. McDermott, R. Floyd, J. Weinschenk C., Overholt, K. (2015). NIST Special Publication 1019 Fire Dynamics Simulator User’s Guide Version 6, National Institute of Standards and Technology.McGrattanK.HostikkaS.McDermottR.FloydJ.WeinschenkC.OverholtK. (2015). , National Institute of Standards and Technology.Search in Google Scholar
Ayala, P., Cantizano, A., Gutierrez-Montes, C., Rein, G. (2013). Influence of atrium roof geometries on the numerical predictions of fire tests under natural ventilation conditions. Energy and Buildings 65, 382–390.AyalaP.CantizanoA.Gutierrez-MontesC.ReinG. (2013). Influence of atrium roof geometries on the numerical predictions of fire tests under natural ventilation conditions. 65, 382–390.10.1016/j.enbuild.2013.06.010Search in Google Scholar
Capote, J.A., Alvear, D., Abreu, O.V., Lazaro, M., Espina, P. (2009). Scale tests of smoke filling in large atria. Fire Technology 45, 201–220.CapoteJ.A.AlvearD.AbreuO.V.LazaroM.EspinaP. (2009). Scale tests of smoke filling in large atria. 45, 201–220.10.1007/s10694-008-0074-4Search in Google Scholar
Ray, S.D., Gong, N.-W., Glicksman, L.R., Paradiso, J.A. (2014). Experimental characterization of full-scale naturally ventilated atrium and validation of CFD simulations. Energy and Buildings 69, 285–291. doi:10.1016/j.enbuild.2013.11.018RayS.D.GongN.-W.GlicksmanL.R.ParadisoJ.A. (2014). Experimental characterization of full-scale naturally ventilated atrium and validation of CFD simulations. 69, 285–291. doi:10.1016/j.enbuild.2013.11.018Open DOISearch in Google Scholar
Rundle, C.A., Lightstone, M.F., Oosthuizen, P., Mouriki, E., (2011). Validation of computational fluid dynamics simulations for atria geometries. Building and Environment 46, 1343–1353.RundleC.A.LightstoneM.F.OosthuizenP.MourikiE., (2011). Validation of computational fluid dynamics simulations for atria geometries. 46, 1343–1353.10.1016/j.buildenv.2010.12.019Search in Google Scholar
Tilley, N., Merci, B. (2009). Application of FDS to adhered spill plumes in atria. Fire Technology 45, 179–188.TilleyN.MerciB. (2009). Application of FDS to adhered spill plumes in atria. 45, 179–188.10.1007/s10694-008-0079-zSearch in Google Scholar
Tilley, N., Merci, B. (2013). Numerical study of smoke extraction for adhered spill plumes in atria: impact of extraction rate and geometrical parameters. Fire Safety Journal 55, 106–115.TilleyN.MerciB. (2013). Numerical study of smoke extraction for adhered spill plumes in atria: impact of extraction rate and geometrical parameters. 55, 106–115.10.1016/j.firesaf.2012.10.022Search in Google Scholar
Tilley, N., Rauwoens, P., Merci, B. (2011). Verification of the accuracy of CFD simulation in small-scale tunnel and atrium fire configurations. Fire Safety Journal 46, 186–193.TilleyN.RauwoensP.MerciB. (2011). Verification of the accuracy of CFD simulation in small-scale tunnel and atrium fire configurations. 46, 186–193.10.1016/j.firesaf.2011.01.007Search in Google Scholar
Yang, P., Tan, X., Xin, W. (2011). Experimental study and numerical simulation for a storehouse fire accident. Building and Environment 46, 1445–1459.YangP.TanX.XinW. (2011). Experimental study and numerical simulation for a storehouse fire accident. 46, 1445–1459.10.1016/j.buildenv.2011.01.012Search in Google Scholar
Xiao, B. (2012). Comparison of numerical and experimental results of fire induced doorway flows. Fire Technology 48, 595–614.XiaoB. (2012). Comparison of numerical and experimental results of fire induced doorway flows. 48, 595–614.10.1007/s10694-009-0131-7Search in Google Scholar
Król M. (2016). Numerical studies on the wind effects on natural smoke venting of atria. International Journal of Ventilation 15, 67–78.KrólM. (2016). Numerical studies on the wind effects on natural smoke venting of atria. 15, 67–78.10.1080/14733315.2016.1173293Search in Google Scholar
Król M., Król A. (2017). Multi-criteria numerical analysis of factors influencing the efficiency of natural smoke venting of atria. Journal of Wind Engineering & Industrial Aerodynamics 170, 149–161.KrólM.KrólA. (2017). Multi-criteria numerical analysis of factors influencing the efficiency of natural smoke venting of atria. 170, 149–161.10.1016/j.jweia.2017.08.012Search in Google Scholar
Węgrzyński W., Krajewski G. (2017). Combined Wind Engineering, Smoke Flow and Evacuation Analysis for a Design of a Natural Smoke and Heat Ventilation System. Procedia Engineering 172, 1243–1251.WęgrzyńskiW.KrajewskiG. (2017). Combined Wind Engineering, Smoke Flow and Evacuation Analysis for a Design of a Natural Smoke and Heat Ventilation System. 172, 1243–1251.10.1016/j.proeng.2017.02.146Search in Google Scholar
Alaya P., Cantizano A., Rien G., Vigne G., Gutierrez-Montes C. (2016). Fire Experiments and Simulations in a Full-Scale Atrium Under Transient and Asymmetric Venting Conditions. Fire Technology 52, 51–78.AlayaP.CantizanoA.RienG.VigneG.Gutierrez-MontesC. (2016). Fire Experiments and Simulations in a Full-Scale Atrium Under Transient and Asymmetric Venting Conditions. 52, 51–78.10.1007/s10694-015-0487-9Search in Google Scholar
Gutierrez-Montes C., Sanmiguel-Rojas E., Burgos M.A., Viedma A. (2012). On the fluid dynamics of the make-up inlet air and the prediction of anomalous fire dynamics in a large-scale facility. Fire Safety Journal 51, 27–41.Gutierrez-MontesC.Sanmiguel-RojasE.BurgosM.A.ViedmaA. (2012). On the fluid dynamics of the make-up inlet air and the prediction of anomalous fire dynamics in a large-scale facility. 51, 27–41.10.1016/j.firesaf.2012.02.007Search in Google Scholar
Gutierrez-Montes C., Sanmiguel-Rojas E., Kaiser A.S., Viedma A. (2008). Numerical model and validation experiments of atrium enclosure fire in a new fire test facility. Building and Environment 43, 1912–1928.Gutierrez-MontesC.Sanmiguel-RojasE.KaiserA.S.ViedmaA. (2008). Numerical model and validation experiments of atrium enclosure fire in a new fire test facility. 43, 1912–1928.10.1016/j.buildenv.2007.11.010Search in Google Scholar
Gutierrez-Montes C., Sanmiguel-Rojas E., Viedma A. (2010). Influence of different makeup air configurations on the fire-induced conditions in an atrium. Building and Environment 45, 2458–2472.Gutierrez-MontesC.Sanmiguel-RojasE.ViedmaA. (2010). Influence of different makeup air configurations on the fire-induced conditions in an atrium. 45, 2458–2472.10.1016/j.buildenv.2010.05.006Search in Google Scholar
Gutierrez-Montes C., Sanmiguel-Rojas E., Viedma A., Rien G. (2009). Experimental data and numerical modeling of 1.3 and 2.3 MW fires in a 20 cubic atrium. Building and Environment 44, 1827–1839.Gutierrez-MontesC.Sanmiguel-RojasE.ViedmaA.RienG. (2009). Experimental data and numerical modeling of 1.3 and 2.3 MW fires in a 20 cubic atrium. 44, 1827–1839.10.1016/j.buildenv.2008.12.010Search in Google Scholar