Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study
Article Category: Research Paper
Published Online: Nov 30, 2024
Page range: 1 - 6
Received: Nov 23, 2023
Accepted: Feb 14, 2024
DOI: https://doi.org/10.15557/jou.2024.0024
Keywords
© 2024 Anna Tomaszkiewicz et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Objective
Thrombosis is a common complication of umbilical artery catheterization. The purpose of this study was to compare the novel ultralow umbilical artery catheter position (catheter tip at the junction of the umbilical and internal iliac arteries) versus the conventional high umbilical artery catheter position (tip in the aorta, above the diaphragm) for the incidence of thrombosis.
Study design
This study was conducted in a nonacademic, tertiary-referral neonatal center. The insertion and placement of the umbilical artery catheter was performed under continuous ultrasound guidance. Serial ultrasound examinations were performed to identify thrombosis in 38 consecutive newborns with an umbilical artery catheter placed in the novel ultralow position. The control group consisted of 50 infants with an umbilical artery catheter placed in the standard position.
Results
The incidence of thrombosis requiring anticoagulant treatment was 22% in neonates with an umbilical artery catheter in the standard position. No thrombosis was detected in those with an umbilical artery catheter placed in the ultralow position. The study and control groups had similar catheter indwelling times (mean, 8.2 ± 4.1 vs. 8.5 ± 4.0 days,
Conclusions
This is the first report to present a novel position for the placement of umbilical artery catheters. The preliminary findings for the novel ultralow umbilical artery catheter position indicate that it may provide a safety benefit over the conventional umbilical artery catheter position.