Abstract

Magnetic resonance imaging (MRI) is a very popular tool for diagnostic applications and research studies. Low-field MR scanners, usually with an open design, are suitable for claustrophobic and obese patients, as well as for children, who may be fearful in closed MR scanners. However, these types of scanners provide lower spatial resolution and a lower signal-to-noise ratio (SNR) if compared with the same examination performed at the same time at high field scanners. It is dominantly caused by the low field strength and other factors, such as radiofrequency noise. Therefore, a long measurement time is usually necessary. This research paper is focused on the development of novel probes and preamplifiers for low-field MR scanners to improve SNR, and thus, shorten the measurement time. In this study, we describe the design of a high impedance preamplifier and a high temperature superconductor (HTS) coil. This novel instrumentation was compared with uncooled and cooled copper coils. Improvement in SNR in the case of an HTS coil is reported.

Keywords

[1] Hoult, D.I., Richards, R.E. (1976). The signal-to-noise ratio of the nuclear magnetic resonance experiment. Journal of Magnetic Resonance, 24 (1), 71-85.10.1016/0022-2364(76)90233-XSearch in Google Scholar

[2] Hoult, D.I., Lauterbur, P.C. (1979). The sensitivity of the zeugmatographic experiment involving human samples. Journal of Magnetic Resonance, 34 (2), 425-433.10.1016/0022-2364(79)90019-2Search in Google Scholar

[3] Ginefri, J.-Ch., Poirier-Quinot, M., Girard, O., Darrasse, L. (2007). Technical aspects: Development, manufacture and installation of a cryo-cooled HTS coil system for high-resolution in-vivo imaging of the mouse at 1.5 T. Methods, 43 (1), 54-67.10.1016/j.ymeth.2007.03.011Search in Google Scholar

[4] Schulder, M., Azmi, H., Biswal, B. (2003). Functional magnetic resonance imaging in a low-field intraoperative scanner. Stereotactic and Functional Neurosurgery, 80 (1-4), 125-131.10.1159/000075172Search in Google Scholar

[5] Valkovič, L., Juráš, V., Gogola, D., Frollo, I. (2012). The early effect of alcohol and caffeine on a BOLD signal measured in human hand at low-field MRI. Applied Magnetic Resonance, 42 (4), 463-471.10.1007/s00723-012-0318-9Search in Google Scholar

[6] Parra-Robles, J., Cross, A.R., Santyr, G.E. (2005). Erratum: “Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs” [Med. Phys. 32, 221-229 (2005)]. Medical Physics, 33 (5), 1525-1526.Search in Google Scholar

[7] Vojtíšek, L., Frollo, I., Valkovič, L., Gogola, D., Juráš, V. (2011). Phased array receiving coils for low field lungs MRI: Design and optimization. Measurement Science Review, 11 (2), 61-66.10.2478/v10048-011-0012-3Search in Google Scholar

[8] Redpath, T.W. (1998). Signal-to-noise ratio in MRI. The British Journal of Radiology, 71, 704-707.10.1259/bjr.71.847.9771379Search in Google Scholar

[9] Lee, H.-L., Lin, I.-T., Chen, J.-H., Horng, H.-E., Yang, H-C. (2005). High-Tc superconducting receiving coils for nuclear magnetic resonance imaging. IEEE Transactions on Applied Superconductivity, 15 (2), 1326-1329.10.1109/TASC.2005.849582Search in Google Scholar

[10] Miller, J.R., Hurlston, S.E., Ma, Q.Y., Face, D.W., Kountz, D.J., MacFall, J.R., Hedlund, L.W., Johnson, G.A. (1999). Performance of a high-temperature superconducting probe for in vivo microscopy at 2.0 T. Magnetic Resonance in Medicine, 41 (1), 72-79.10.1002/(SICI)1522-2594(199901)41:1<72::AID-MRM11>3.0.CO;2-ASearch in Google Scholar

[11] Cheng, M.-Ch. (2004). High temperature superconductor tape RF volume coil for MRI systems. Thesis, The University of Hong Kong.Search in Google Scholar

[12] Giovannetti, G., Francesconi, R., Landini, L., Santarelli, M.F., Positano, V., Viti, V., Benassi, A. (2004). Conductor geometry and capacitor quality for performance optimization of low-frequency birdcage coils. Concepts in Magnetic Resonance B, 20B (1), 9-16.10.1002/cmr.b.20005Search in Google Scholar

[13] Mispelter, J., Lupu, M., Briguet, A. (2006). NMR Probeheads: For Biophysical and Biomedical Experiments, 1st Edition. Imperial College, 596.Search in Google Scholar

[14] Ma, Q.Y., Chan, K.C., Kacher, D.F., Gao, E., Chow, M.S., Wong, K.K., Xu, H., Yang, E.S., Young, G.S., Miller, J.R., Jolesz, F.A. (2003). Superconducting RF coils for clinical MR imaging at low field. Academic Radiology, 10 (9), 978-987.10.1016/S1076-6332(03)00110-7Search in Google Scholar

[15] Nouls, J.C., Izenson, M.G., Greeley, H.P., Johnson, G.A. (2008). Design of a superconducting volume coil for magnetic resonance microscopy of the mouse brain. Journal of Magnetic Resonance, 191 (2), 231-238.10.1016/j.jmr.2007.12.018Search in Google Scholar

[16] Cheng, M.C., Lee, K.H., Chan, K.C., Wong, K.K., Yang, E.S. (2003). HTS tape RF coil for low field MRI. In Proceedings of the International Society for Magnetic Resonance in Medicine, Toronto, Ontario, Canada, 2359.Search in Google Scholar

[17] Ginefri, J.-Ch., Darrasse, L., Crozat, P. (2001). Hightemperature superconducting surface coil for in vivo microimaging of the human skin. Magnetic Resonance in Medicine, 45 (3), 376-382.10.1002/1522-2594(200103)45:3<376::AID-MRM1049>3.0.CO;2-RSearch in Google Scholar

[18] Darrasse, L., Ginefri, J.-Ch. (2003). Perspectives with cryogenic RF probes in biomedical MRI. Biochimie, 85 (9), 915-937.10.1016/j.biochi.2003.09.016Search in Google Scholar

[19] Yuan, J., Shen, G.X., Wang, Ch., Wu, B., Qu, P. (2004). Use of Bi-2223 multifilamentary tapes as RF coils for 1.5 T MRI application. Physica C, 415 (4), 189-196.Search in Google Scholar

Recommended articles from Trend MD

Plan your remote conference with Sciendo