Cite

[1] “IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems,” in IEEE Std 519-2014 (Revision of IEEE Std 519-1992), pp. 1–29, June 11 2014. https://doi.org/10.1109/IEEESTD.2014.682645910.1109/IEEESTD.2014.6826459Open DOISearch in Google Scholar

[2] M. Rashid, Power Electronics Handbook, 3nd ed. Boston: Elsevier Inc., 2011, p. 1409.Search in Google Scholar

[3] F. L. Luo and H. Ye, Power Electronics: Advanced Conversion Technologies. Boca Raton: CRC Press, 2010, p. 745.Search in Google Scholar

[4] S. Choi, P. N. Enjeti, and I. J. Pitel, “Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier-type utility interface,” IEEE Transactions on Power Electronics, vol. 11, no. 5, pp. 680–690, Sep. 1996. https://doi.org/10.1109/63.53540010.1109/63.535400Open DOISearch in Google Scholar

[5] K. Oguchi, G. Maeda, N. Hoshi, and T. Kubata, “Coupling rectifier systems with harmonic cancelling reactors,” IEEE Industry Applications Magazine, vol. 7, no. 4, pp. 53–63, 2001. https://doi.org/10.1109/2943.93099110.1109/2943.930991Search in Google Scholar

[6] Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current <= 16 A per phase), IEC 61000-3-2:2014.Search in Google Scholar

[7] Electromagnetic compatibility (EMC) – Part 3-4: Limits – Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A, IEC 61000-3-4:1998.Search in Google Scholar

[8] Electromagnetic compatibility (EMC) – Part 3-6: Limits – Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems, IEC 61000-3-6:2008.Search in Google Scholar

[9] Electromagnetic compatibility (EMC) – Part 4-19: Testing and measurement techniques – Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports, IEC 61000-4-19:2014.Search in Google Scholar

[10] G. F. Bartak and A. Abart, “EMI of emissions in the frequency range 2 kHz – 150 kHz,” 22nd International Conference and Exhibition on Electricity Distribution (CIRED 2013), 2013, pp. 1–4. https://doi.org/10.1049/cp.2013.115110.1049/cp.2013.1151Search in Google Scholar

[11] D. A. Paice, Power Electronics Converter Harmonics : Multipulse Methods for Clean Power, Wiley-IEEE Press, 1999, p. 222.10.1109/9780470545560Search in Google Scholar

[12] K. Matsui, “A dual thyristor converter reducing harmonics of power supply without input transformer,” Electrical Engineering in Japan, vol. 112, no. 3, pp. 143–153, 1992. https://doi.org/10.1002/eej.439112031510.1002/eej.4391120315Open DOISearch in Google Scholar

eISSN:
2255-9159
Language:
English
Publication timeframe:
2 times per year
Journal Subjects: