Fig. 1

Anatomical positions of REG, EEG electrodes and LDF probe are shown implanted in a rat skull (dorsal view). Standard orientation points in rat neurophysiology: bregma and lambda points and sutura between bones.
Anatomical positions of REG, EEG electrodes and LDF probe are shown implanted in a rat skull (dorsal view). Standard orientation points in rat neurophysiology: bregma and lambda points and sutura between bones.

Fig. 2

Block schematics showing REG and LDF measured during rat CO2 inhalation challenges and data processing of resulting signals stored in a computer (PC). Data were first processed using DataLyser software to process analog signals; numbers generated were then put into an Excel software spread sheet for calculation of percentages of control values, group mean and SD. Next, percent values of REG and LDF were put into a Prism software spreadsheet for calculation of ROC and AUC.
Block schematics showing REG and LDF measured during rat CO2 inhalation challenges and data processing of resulting signals stored in a computer (PC). Data were first processed using DataLyser software to process analog signals; numbers generated were then put into an Excel software spread sheet for calculation of percentages of control values, group mean and SD. Next, percent values of REG and LDF were put into a Prism software spreadsheet for calculation of ROC and AUC.

Fig. 3

Impact of CO2 inhalation on LDF flux and REG signals, in real time: CO2 increases were followed by simultaneous increases in LDF flux and REG signal amplitudes. For all traces, Y axis is shown in volts; X axis is shown in seconds. Traces, from top, are REG raw signal; REG proc (processed signal, displayed as a running integral); EKG; Respiration (measured by bioimpedance); LDF flux; inhaled CO2.
Impact of CO2 inhalation on LDF flux and REG signals, in real time: CO2 increases were followed by simultaneous increases in LDF flux and REG signal amplitudes. For all traces, Y axis is shown in volts; X axis is shown in seconds. Traces, from top, are REG raw signal; REG proc (processed signal, displayed as a running integral); EKG; Respiration (measured by bioimpedance); LDF flux; inhaled CO2.

Fig. 4

ROC curve of LDF and REG. Area under curve (AUC): 0.8394 with p<0.0001; Std. error: 0.03693; 95 % confidence interval: 0.7670 to 0.9118. Figure and numbers are presented as Prism program shown and calculated from the percent values of REG and LDF signals.
ROC curve of LDF and REG. Area under curve (AUC): 0.8394 with p<0.0001; Std. error: 0.03693; 95 % confidence interval: 0.7670 to 0.9118. Figure and numbers are presented as Prism program shown and calculated from the percent values of REG and LDF signals.