[Biggs P. J, Ling C. C. Electron as the cause of the observe dmax shift with field size in high energy beams. Med Phys. 1979; 6: 291-295.10.1118/1.594580]Search in Google Scholar
[Biggs P J, Russell M. D. An investigation into the presence of secondary electrons in megavoltage photon beams. Phys Med Biol. 1983; 28: 1033-1043.10.1088/0031-9155/28/9/003]Search in Google Scholar
[Bjarngard B. E, Vadash P. Analysis of central-axis doses for high energy x-rays. Med Phys. 1995; 22: 1191-1195.10.1118/1.597509]Search in Google Scholar
[Ding G. X. An investigations of accelerator head scatter and output factor in air. Med Phys. 2004; 31: 2527-2533.10.1118/1.1784131]Search in Google Scholar
[Dutreix A, Bjarngard B. E, Bridier A, Mijnheer B, Shaw J.E, Svensson H. Monitor unit calculation for high energy photon beams. The Netherlands, ESTRO and Garant Publishers, 1997: 101-104.]Search in Google Scholar
[Heukelom S, Lanson J. H, Mijnheer B. J. Wedge factor constituents of higher-energy photon beams: head and phantom scatter dose components. Radiother Oncol. 1994; 32: 73-83.10.1016/0167-8140(94)90451-0]Search in Google Scholar
[Holt J. G, Laughlin J. S, Moroney J. P. The extension of the concept of tissue-air ratios (TAR) to high-energy x-ray beams. Radiology. 1970; 96: 437-44610.1148/96.2.4374988187]Search in Google Scholar
[Johns H. E, Cunningham J. R. The Physics of Radiology. 4th edition. Charles C. Thomas, Springfield. 1983: 336-381.]Search in Google Scholar
[Jursinic P A, Measurement of head scatter factors of linear accelerators with columnar miniphantoms. Med Phys. 2006; 33: 1720-1728.10.1118/1.220114816872079]Search in Google Scholar
[Karzmark C J, Deubert A, Loevinger R. Tissue-phantom ratios—An aid to treatment planning. Brit J Radiol. 1965; 38: 158-159.]Search in Google Scholar
[Khan F M, Sewchand W, Lee J, Williamson J F. Revision of tissue-maximum ratio and scatter-maximum ratio concepts for cobalt 60 and higher energy x-ray beams. Med Phys. 1980; 7: 230-237.10.1118/1.5946486771511]Search in Google Scholar
[Luxton G, Astrahan M A. Characteristics of high energy photon beam of a 25 MV accelerator. Med Phys. 1988; 15: 82-87.10.1118/1.5961633127667]Search in Google Scholar
[Luxton G, Astrahan M A, Output factor constituents of a high energy photon beam. Med Phys. 1988; 15: 88-91.10.1118/1.5963003127668]Search in Google Scholar
[Mackie T R, Scrimger J W. Contamination of a 15-MV photon beam by electrons and scattered photons. Radiology. 1982; 144: 403-409.10.1148/radiology.144.2.68068536806853]Search in Google Scholar
[McKenzie A L, Stevens P H. Twenty-five years of MTRP—A theoretical and experimental analysis. Phys Med Biol. 1995; 40: 17-29.10.1088/0031-9155/40/1/0037708839]Search in Google Scholar
[Sjogren R, Karlsson M. Electron contamination in clinical high energy photon beams. Med Phys. 1996; 23: 1873-1881.10.1118/1.5977508947901]Search in Google Scholar
[Tatcher M, Bjarngard B E. Head-scatter factors in rectangular photon fields. Med Phys. 1993; 20: 205-206.10.1118/1.5970878455501]Search in Google Scholar
[Van Gasteren J J M, Heukelom S, Jager H N, Mijnheer B J, van Kleffens H J, van der Laarse R. et al. Determination and use of scatter correction factors of megavoltage photon beams. Netherlands Commission on Radiation Dosimetry. NCS Report No. 12. 1998.10.25030/ncs-012]Search in Google Scholar
[Venselaar J, Heukelom S, Jager N, Mijnheer B, van der Laarse R, van Gasteren H, et al. Effect of electron contamination on scatter correction factors for photon beam dosimetry. Med Phys. 1999; 26: 2099-2106.10.1118/1.59872510535626]Search in Google Scholar
[Weber L, Nilsson P, Ahnesjo A. Build-up cap materials for measurements of photon head-scatter factors, Phys Med Biol. 1997; 42: 1875-1886.10.1088/0031-9155/42/10/0029364584]Search in Google Scholar
[Zhu T C, Lam K L, Li X A, Charlie Ma C-M, Palta J R, et al. Report of AAPM Therapy Physic Committee task Group 74: In-air output ratio, Sc, for megavoltage photon beams. Med Phys. 2009; 36: 5261-5291.10.1118/1.322736719994536]Search in Google Scholar