Login
Registrati
Reimposta password
Pubblica & Distribuisci
Soluzioni Editoriali
Soluzioni di Distribuzione
Temi
Architettura e design
Arti
Business e Economia
Chimica
Chimica industriale
Farmacia
Filosofia
Fisica
Geoscienze
Ingegneria
Interesse generale
Legge
Letteratura
Linguistica e semiotica
Matematica
Medicina
Musica
Scienze bibliotecarie e dell'informazione, studi library
Scienze dei materiali
Scienze della vita
Scienze informatiche
Scienze sociali
Sport e tempo libero
Storia
Studi classici e del Vicino Oriente antico
Studi culturali
Studi ebraici
Teologia e religione
Pubblicazioni
Riviste
Libri
Atti
Editori
Blog
Contatti
Cerca
EUR
USD
GBP
Italiano
English
Deutsch
Polski
Español
Français
Italiano
Carrello
Home
Riviste
Radiology and Oncology
Volume 52 (2018): Numero 3 (September 2018)
Accesso libero
Singular value decomposition analysis of back projection operator of maximum likelihood expectation maximization PET image reconstruction
Vencel Somai
Vencel Somai
,
David Legrady
David Legrady
e
Gabor Tolnai
Gabor Tolnai
| 24 mar 2018
Radiology and Oncology
Volume 52 (2018): Numero 3 (September 2018)
INFORMAZIONI SU QUESTO ARTICOLO
Articolo precedente
Articolo Successivo
Sommario
Articolo
Immagini e tabelle
Bibliografia
Autori
Articoli in questo Numero
Anteprima
PDF
Cita
CONDIVIDI
Article Category:
Research Article
Pubblicato online:
24 mar 2018
Pagine:
337 - 345
Ricevuto:
28 ago 2017
Accettato:
22 feb 2018
DOI:
https://doi.org/10.2478/raon-2018-0013
© 2018 Vencel Somai, David Legrady, Gabor Tolnai, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Figure 1
Top view of the reconstruction of the cylinder-ring mathematical phantom of the full system with faithful modelling in the back projection. Light grey area represents water, dark grey area represents bone material. Underestimated activity and increased full width at half maximum (FWHM) / full width at tenth maximum (FWTM) can be seen for voxels located in water. FWHM and FWTM are calculated along the ring. Red line indicates the phantom ideal FWHM.
Figure 2
Top view of the reconstruction of the cylinder-ring mathematical phantom of the full system with simplified modelling in the back projection. Homogeneous activity estimate and full width at half maximum (FWHM) can be seen along the ring, neglect of positron range in theback projection abolished the artefact of Figure 1 and phantom ideal FWHM is reached.
Figure 3
Mathematical phantom and system geometry for 1D model. 1-128 voxels are located in bone material, 129–256 voxels are located in water.
Figure 4
Singular values of the system matrix for positron range neglecting and modelling case. Increased values for the former imply the faster convergence of the corresponding (first 133) basis components of the activity estimate.
Figure 5
One of the voxel space singular vectors of the system matrices corresponding to positron range neglect (left – back projection posrange OFF) and positron range modelling (right – back projection posrange ON). Back projection posrange OFF reflects only the symmetries of the geometry. Back projection posrange ON accounts for the material map as well, increased position uncertainty due to longer average positron free path implies smaller space-frequency in water area.
Figure 6
Absolute value of the spectral coefficients of the measurement-forward projection Hadamard ratio in the sinogram basis corresponding to positron range neglect (left – back projection posrange OFF) and positron range modelling (right – back projection posrange ON). Faster decay means less information gathered as the coefficients of the horizontal plateau are corrupted by noise thus it represents an error level estimate. Due to one to one correspondence property of SVD between sinogram and voxel space singular (basis) vectors these basis coefficients of the activity are not hoped to be correctly estimated
Figure 7
The L2-norm of the difference between the activity distribution and the current estimate after a given number of iterations. Smaller value means better agreement. Subfigure on the left shows the result of the noiseless test case where the convergence of back projection posrange ON setting to the exact solution and the convergence of back projection posrange OFF setting to an other fix point is presented. Subfigure on the right shows the result of a simulated reconstruction with 106 positron used for measurement generation and in both forward and back projection Monte Carlo simulations. After slower initial convergence back projection posrange ON reaches much better activity estimate. Back projection posrange OFF converges to a different fix point similarly to noiseless case.
Figure 8
The L2-norm of the difference between the activity distribution and the current estimate after a given number of iterations. Smaller value means better agreement. Reconstruction with SVD filter outperforms the best setting so far in terms of faster initial convergence and the farther starting point of increasing discrepancy due to semi-convergence. Also the faster initial convergence of positron range neglecting back projection can be seen compared to positron range modelling back projection.
Anteprima