This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Michalski A, Atyeo J, Cox J, Rinks M, Morgia M, Lamoury G. A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes. Medical Dosimetry. 2014;39(2):163-168. https://doi.org/10.1016/j.meddos.2013.12.003Search in Google Scholar
Den RB, Doemer A, Kubicek G, et al. Daily Image Guidance With Cone-Beam Computed Tomography for Head-and-Neck Cancer Intensity-Modulated Radiotherapy: A Prospective Study. International Journal of Radiation Oncology*Biology*Physics. 2010;76(5):1353-1359. https://doi.org/10.1016/j.ijrobp.2009.03.059Search in Google Scholar
Ding GX, Alaei P, Curran B, et al. Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180. Medical Physics. 2018;45(5). https://doi.org/10.1002/mp.12824Search in Google Scholar
Giaddui T, Cui Y, Galvin J, Yu Y, Xiao Y. Comparative dose evaluations between XVI and OBI cone beam CT systems using Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters. Medical Physics. 2013;40(6Part1):062102-1-12. https://doi.org/10.1118/1.4803466Search in Google Scholar
Brunner CC, Stern SH, Minniti R, Parry MI, Skopec M, Chakrabarti K. CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions. Med Phys. 2013;40(8):081917. https://doi.org/10.1118/1.4815964Search in Google Scholar
Ernst M, Manser P, Dula K, Volken W, Stampanoni MF, Fix MK. TLD measurements and Monte Carlo calculations of head and neck organ and effective doses for cone beam computed tomography using 3D Accuitomo 170. Dentomaxillofacial Radiology. 2017;46(7):20170047. https://doi.org/10.1259/dmfr.20170047Search in Google Scholar
Al‐Senan RM, Hatab MR. Characteristics of an OSLD in the diagnostic energy range. Medical Physics. 2011;38(7):4396-4405. https://doi.org/10.1118/1.3602456Search in Google Scholar
Davis SD, Ross CK, Mobit NP, Van der Zwan L, Chase WJ, Shortt KR. The response of lif thermoluminescence dosemeters to photon beams in the energy range from 30 kV x rays to 60Co gamma rays. Radiation Protection Dosimetry. 2003;106(1):33-43. https://doi.org/10.1093/oxfordjournals.rpd.a006332Search in Google Scholar
Nunn AA, Davis SD, Micka JA, DeWerd LA. LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x‐ray spectra in the range of 20–250 kVp relative to. Medical Physics. 2008;35(5):1859-1869. https://doi.org/10.1118/1.2898137Search in Google Scholar
Reitz I, Hesse BM, Nill S, Tücking T, Oelfke U. Enhancement of image quality with a fast iterative scatter and beam hardening correction method for kV CBCT. Zeitschrift für Medizinische Physik. 2009;19(3):158-172. https://doi.org/10.1016/j.zemedi.2009.03.001Search in Google Scholar
Tomic N, Devic S, DeBlois F, Seuntjens J. Reference radiochromic film dosimetry in kilovoltage photon beams during CBCT image acquisition. Medical Physics. 2010;37(3):1083-1092. https://doi.org/10.1118/1.3302140Search in Google Scholar
Tomic N, Quintero C, Whiting BR, et al. Characterization of calibration curves and energy dependence GafChromicTM XR-QA2 model based radiochromic film dosimetry system. Med Phys. 2014;41(6Part1):062105. https://doi.org/10.1118/1.4876295Search in Google Scholar
Nakajima E, Sato H. Characterization of a new radiochromic film (LD-V1) using mammographic beam qualities. Zeitschrift für Medizinische Physik. Published online June 2023. https://doi.org/10.1016/j.zemedi.2023.05.004Search in Google Scholar
Radcal Corporation. Accessed September 13, 2023. https://radcal.com/wp-content/uploads/2016/10/radcal-10X6-6-chamber-spec-sheet.pdfSearch in Google Scholar
Niroomand‐Rad A, Chiu‐Tsao S, Grams MP, et al. Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG‐55. Medical Physics. 2020;47(12):5986-6025. https://doi.org/10.1002/mp.14497Search in Google Scholar
Devic S, Seuntjens J, Sham E, et al. Precise radiochromic film dosimetry using a flat-bed document scanner. Med Phys. 2005;32(7Part1):2245-2253. https://doi.org/10.1118/1.1929253Search in Google Scholar
Bouchard H, Lacroix F, Beaudoin G, Carrier J, Kawrakow I. On the characterization and uncertainty analysis of radiochromic film dosimetry. Medical Physics. 2009;36(6Part1):1931-1946. https://doi.org/10.1118/1.3121488Search in Google Scholar
Ashland Inc. Who has pinpoint precision for critical analysis? Ashland Inc. Accessed January 12, 2023. https://www.ashland.com/file_source/Ashland/Documents/PHA22-039_Gafchromic_LDV1_brochure_060322.pdfSearch in Google Scholar