Innovative Hybrid War Strategy Optimization with Incremental Conductance for Maximum Power Point Tracking in Partially Shaded Photovoltaic Systems
21 dic 2024
INFORMAZIONI SU QUESTO ARTICOLO
Categoria dell'articolo: Research paper
Pubblicato online: 21 dic 2024
Pagine: 1 - 18
Ricevuto: 18 set 2024
Accettato: 15 nov 2024
DOI: https://doi.org/10.2478/pead-2025-0001
Parole chiave
© 2025 Hechmi Khaterchi et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

Figure 7.

Figure 8.

Figure 9.

Figure 10.

Figure 11.

Comparison of algorithm performance across different scenarios
Algorithm | Convergence time (ms) | Duty cycle | Tracking error (%) | Ppv (w) | Efficiency (%) |
---|---|---|---|---|---|
Scenario 1: Ir1 = Ir2 = 1000 W/m2, T1 = T2 = 25 C, |
|||||
IC | 648.689 | 0.7103 | 0.9641 | 426.130 | 99.96 |
P&O | 628.276 | 0.7108 | 0.8943 | 426.124 | 99.96 |
WSO | 352.368 | 0.7101 | 0.9919 | 426.106 | 99.95 |
398.437 | 0.7116 | 426.148 | |||
Scenario 2: Ir1 = 1000 W/m2, Ir2 = 400 W/m2, T1 = T2 = 25 C, |
|||||
IC | 768.902 | 0.5305 | 34.0041 | 189.453 | 91.35 |
P&O | 517.483 | 0.5308 | 33.9668 | 189.450 | 91.35 |
WSO | 254.545 | 0.7925 | 1.4105 | 204.705 | 98.70 |
271.329 | 0.7938 | 207.356 | |||
Scenario 3: Ir1 = 800 W/m2, Ir2 = 400 W/m2, T1 = T2 = 25 C, |
|||||
IC | 567.832 | 0.7704 | 39.9145 | 167.000 | 89.02 |
P&O | 405.594 | 0.7699 | 39.8236 | 167.200 | 89.13 |
WSO | 271.329 | 0.7714 | 40.0961 | 167.200 | 89.13 |
442.281 | 0.5313 | 187.600 | |||
Scenario 4: Ir1 = 600 W/m2, Ir2 = 400 W/m2, T1 = T2 = 25 C, |
|||||
IC | 623.776 | 0.7401 | 34.2933 | 125.800 | 68.15 |
P&O | 433.566 | 0.7400 | 34.2752 | 125.900 | 68.20 |
WSO | 338.462 | 0.7391 | 34.1119 | 125.700 | 68.09 |
492.350 | 0.5378 | 184.500 |
Electrical specifications of the boost converter_
Parameter | Noun | Value |
---|---|---|
Boost converter | ||
Inductance (mH) | 1.1478 | |
Input capacitor ( |
6,800 | |
Output capacitor ( |
3,300 | |
PWM frequency (kHz) | 10 | |
Load | ||
Resistive load (Ω) | 100 |
Performance comparison of the proposed WSO-IC with different MPPT algorithms
MPPT algorithm | Efficiency (%) | Tracking time (s) |
---|---|---|
P&O ( |
96.08 | |
FL ( |
96.94 | 0.35 |
PSO ( |
99.62 | 0.50 |
GWO ( |
97.08 | 0.78 |
HOA ( |
99.76 | 0.33 |
0.398 |
Optimal duty cycle calculated for each scenario
Scenario | D_opt | |
---|---|---|
Scenario 1 | D_opt_G = |
|
Scenario 2 | D_opt_G = |
|
D_opt_L = 0.54699656 | ||
Scenario 3 | D_opt_G = |
|
D_opt_L = 0.77950357 | ||
Scenario 4 | D_opt_G = |
|
D_opt_L = 0.74620251 |
Electrical specifications of the PV panels_
Pmax | Voc | Isc | Vmp | Imp | |
---|---|---|---|---|---|
PV module | 213.15 W | 36.3 V | 7.84 A | 29 V | 7.35 A |