Electromagnetic Shielding Performance Measurement for Braided-Shield Power Cables at Low Frequency Regimes

INFORMAZIONI SU QUESTO ARTICOLO

Cita

Although various measurement techniques have been applied to both qualitative and quantitative evaluation for the electromagnetic shielding performance of braided-shield power cables, the existing measurements cannot directly assess the low-frequency shielding performance (typically below 100 kHz) due to factors such as ground-loop effects and dynamic range problem in measurement. To solve these, an improved shield reduction factor method, based on gain (T/R) rather than scattering parameters, is proposed to evaluate the shielding performance of braided-shield power cables from 25 Hz to 1 MHz. In this work, we highlight the implementation of measurement setup to avoid the effects of ground-loop and stray electromagnetic field. Meanwhile, the test cell is simplified according to the definition of the shield reduction factor in order to obtain the gain (T/R) parameters, which can be used to calculate transfer impedance as well. From the measurements we present more intuitive evaluation of shielding behavior of braided-shield power cables at low frequency regimes, and showcase a detailed comparative discussion between transfer impedance and shield reduction factor. The proposed shield reduction factor method is expected to be a useful way for the evaluation of the low frequency shielding performance of braided-shield cables.