Improvement of cryogenic fluid storage and transfer technology for in-space propulsion and storage systems is required for long-term space missions. Screened channel liquid acquisition devices (LADs) have long been used with storable propellants to deliver vapor-free liquid during engine restart and liquid transfer processes. The use of LADs with cryogenic fluids is problematic due to low temperatures associated with cryogenic fluids. External heat leaks will cause vapor bubbles to form within the LADs that are difficult to remove in the existing designs. A tapered LAD channel has been proposed to reliably remove vapor bubbles within the device without costly thrusting maneuvers or active separation systems. A model has been developed to predict bubble movement within tapered LAD channels, and subsequent ground testing was completed with a simulant fluid to provide model validation data. Suborbital microgravity testing of tapered LAD technology was recently completed with two different simulant fluids and demonstrated that the concept can passively expel vapor bubbles within the channel. Two additional suborbital flights have been funded to further develop this technology by investigating the performance of larger scale versions of the design.