This work deals with the problem of X-ray stress determination on the samples dedicated to fatigue tests. A number of research studies point out the fact that the processing of hard, difficult to machine materials like nickel superalloys, reveals more than one trend of residual stress versus working parameters of behaviour (Lavella and Berruti, 2010). Many papers have shown that the residual stresses are dependent on a combination of a number of factors. When the above is taken into account simultaneously with the requirements of the internal General Electric specification for the fatigue tests samples preparation (