Accesso libero

Two Techniques for the Analysis of WS-3 With Potential Application to the Analysis of Other Cooling Agents *

 e   
04 apr 2023
INFORMAZIONI SU QUESTO ARTICOLO

Cita
Scarica la copertina

Figure 1.

Chemical structures of four compounds with cooling properties.
Chemical structures of four compounds with cooling properties.

Figure 2.

Typical LC/MS chromatogram for a standard containing 0.78 µg/mL of each analyte and 12.5 µg/mL internal standard (IS).
Typical LC/MS chromatogram for a standard containing 0.78 µg/mL of each analyte and 12.5 µg/mL internal standard (IS).

Figure 3.

Typical GC/MS chromatogram of a standard mixture containing each coolant agent at 25 µg/mL and the internal standard (I.S.) at 12.5 µg/mL.
Typical GC/MS chromatogram of a standard mixture containing each coolant agent at 25 µg/mL and the internal standard (I.S.) at 12.5 µg/mL.

Results of WS-3 analysis by GC/MS in four analyzed nicotine pouches_

Samples Level of WS-3 (mg/g) RSD (%)
Sample 1 a 0.514
Sample 1 b 0.469
Sample 1 c 0.490
Average for pouch 1 0.491 4.59

Level of WS-3 per g of tobacco in several cigarettes_

Samples Level of WS-3 (mg/g) RSD (%)
Experimental cigarette 1 (LC/MS)   2.878 1.93
Experimental cigarette 1 (GC/MS)   2.991 4.93
Experimental cigarette 2   1.954 3.52
Experimental cigarette 3 < LOQ
Experimental cigarette 4   1.484 0.02
Commercial cigarette 1 < LOQ
Commercial cigarette 2 < LOQ

Results for the measurement of WS-3 in cigarette smoke_

Smoking Level of WS-3 (mg/g) RSD (%)
ISO 0.196 1.31
HCA 0.240 0.79

The parameters a, b, and c used for calibration for each cooling agent as well as the corresponding correlation coefficient R2_

Compound a b c R2
WS-23 -3.91604E-14 5.64097E-06 -0.05549529 0.9987
WS-3     4.4729E-13 1.77042E-06       0.197442 0.9989
Evercool 190 -5.22754E-14 2.58027E-06 -0.02307681 0.9990
Evercool 180   1.61678E-12 6.22688E-06 0.007595738 0.9982

Results of WS-3 analysis by LC/MS in four analyzed nicotine pouches_

Samples Level of WS-3 (mg/g) RSD (%)
Sample 1 a   0.496
Sample 1 b   0.513
Sample 1 c   0.496
Average for pouch 1   0.502 1.99
Sample 2 a < LOQ
Sample 2 b < LOQ
Sample 2 c < LOQ
Average for pouch 2 < LOQ
Sample 3 a < LOQ
Sample 3 b < LOQ
Sample 3 c < LOQ
Average for pouch 3 < LOQ
Sample 4 a 0.105
Sample 4 b 0.103
Sample 4 c 0.104
Average for pouch 4 0.104 0.84

Results for WS-3 levels in some flavor solutions_

Sample WS-3 (mg/g) RSD (%)
Flavor 1 125.69 4.33
Flavor 2 117.56 0.63
Flavor 3 123.72 2.74
Flavor 4 112.27 2.59
Flavor 5 119.50 3.82
Flavor 6 118.36 0.24
Flavor 7 121.13 2.95
Flavor 8 123.00 1.82
Flavor 9 113.89 1.84

The LOQ values for the GC/MS method of analysis of cooling agents_

Compound LOQ (μg/mL)
WS-23 1.56
WS-3 1.56
Evercool 190 3.13
Evercool 180 6.25

The recovery of WS-3 from a tobacco sample spiked with three levels of analyte and the corresponding recovery levels_

Taken (mg/g) Analyzed (mg/g) Recovery (%) RSD (%)
2.0 2.018 100.9 3.316
1.0 1.004 100.4 3.444
0.5 0.500 100.0 1.375

Gradient conditions for coolants HPLC separation_

Time (min) A (%) B (%)
0.0 95 5
0.5 95 5
2.0 40 60
4.0 40 60
5.0 95 5
6.0 95 5

Samples analyzed in this study_

Sample type Material type Analytical procedure
Experimental cigarette 1 a Tobacco from cigarette LC/MS, GC/MS
Experimental cigarette 2 a Tobacco from cigarette LC/MS
Experimental cigarette 3 a Tobacco from cigarette LC/MS
Experimental cigarette 4 a Tobacco from cigarette LC/MS
Commercial cigarette 1 b Tobacco from cigarette LC/MS
Commercial cigarette 2 b Tobacco from cigarette LC/MS
Nicotine pouch 1 b Nicotine pouch LC/MS, GC/MS
Nicotine pouch 2 b Nicotine pouch LC/MS
Nicotine pouch 3 b Nicotine pouch LC/MS
Nicotine pouch 4 b Nicotine pouch LC/MS
Experimental cigarette 1 a Smoke ISO LC/MS
Experimental cigarette 1 a Smoke HCA LC/MS
Flavor (1) to flavor (9) a Flavor solution LC/MS

Ion used to generate the extracted peak, the parameters a and b used for calibration for each cooling agent as well as the corresponding correlation coefficient R2_

Compound m/z for peak area a b R2
I.S. (nicotinamide) 122,1 -
WS-23 129,1 0 0,218801 0,9998
WS-3 211,2 0 -0,17814 0,9995
Evercool 190 288,1 0 2,604558 0,999
Evercool 180 298,1 0 3,44324 0,9986

Typical parameters for the GC/MS analysis_

Parameter Description Parameter Description
Initial oven temperature 37 °C Carrier gas Helium
Initial time 1.0 min Injection volume 1 μL
Oven ramp rate 30 °C/min Flow mode Constant flow
Oven temperature 70 °C Flow rate 1.1 mL/min
Final time first ramp 0 min Nominal initial pressure 7.95 psi
Oven ramp rate 20 °C/min GC outlet MSD
Oven final temperature 300 °C MSD transfer line temperature 270 °C
Final time 6.4 min Ion source temperature 230 °C
Total run time 20.0 min Quadrupole temperature 150 °C
Inlet temperature 280 °C MSD Gain 1
Inlet mode Split MSD solvent delay 5.0 min
Split ratio 10:1 Mass range 33–350 a.u.
Lingua:
Inglese
Frequenza di pubblicazione:
4 volte all'anno
Argomenti della rivista:
Interesse generale, Scienze biologiche, Scienze della vita, altro, Fisica, Fisica, altro