Using Computer Simulation to Effectively Solve Power Transmission Problems for Non-Sinusoidal Waveforms
05 set 2025
INFORMAZIONI SU QUESTO ARTICOLO
Pubblicato online: 05 set 2025
Pagine: 362 - 368
Ricevuto: 07 feb 2025
Accettato: 10 giu 2025
DOI: https://doi.org/10.2478/ama-2025-0043
Parole chiave
© 2025 Maciej KLEBBA et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Fig. 1.
![Arc lamp circuit [16]](https://sciendo-parsed.s3.eu-central-1.amazonaws.com/68c7ca3481e1b93419683492/j_ama-2025-0043_fig_001.jpg?X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Credential=AKIA6AP2G7AKOUXAVR44%2F20250921%2Feu-central-1%2Fs3%2Faws4_request&X-Amz-Date=20250921T110508Z&X-Amz-Expires=3600&X-Amz-Signature=fe83bad2254f2c52ea8e1c14a866ea7c1cbdb31787384773060aa14bf36f54da&X-Amz-SignedHeaders=host&x-amz-checksum-mode=ENABLED&x-id=GetObject)
Fig. 1.
![Purely resistive circuit with TRIAC [17]](https://sciendo-parsed.s3.eu-central-1.amazonaws.com/68c7ca3481e1b93419683492/j_ama-2025-0043_fig_002.jpg?X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Credential=AKIA6AP2G7AKOUXAVR44%2F20250921%2Feu-central-1%2Fs3%2Faws4_request&X-Amz-Date=20250921T110508Z&X-Amz-Expires=3600&X-Amz-Signature=e9da33ff6ff474b40ee9fac55a0db821d82e51edf7ff23e576b2c8a4b3424d47&X-Amz-SignedHeaders=host&x-amz-checksum-mode=ENABLED&x-id=GetObject)
Fig. 2.
![Current waveform in the circuit with TRIAC [17]](https://sciendo-parsed.s3.eu-central-1.amazonaws.com/68c7ca3481e1b93419683492/j_ama-2025-0043_fig_003.jpg?X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Credential=AKIA6AP2G7AKOUXAVR44%2F20250921%2Feu-central-1%2Fs3%2Faws4_request&X-Amz-Date=20250921T110508Z&X-Amz-Expires=3600&X-Amz-Signature=3ddabb119422ed51374ba669affc907c8141bb6c04dadcea0c60066c0240f8a4&X-Amz-SignedHeaders=host&x-amz-checksum-mode=ENABLED&x-id=GetObject)
Fig. 3.

Fig. 4.

Fig. 5.

Fig. 6.

Fig. 7.

Fig. 8.

Real object results table
Circuit type | TRIAC firing angle | Active power | Reactive power | Apparent power | power factor | Voltage | Current |
---|---|---|---|---|---|---|---|
⸰ | W | Var | VA | V | mA | ||
a | 0 | 43.1 | 0 | 43.1 | 1 | 103 | 420 |
b | 0 | 43.1 | 0 | 43.1 | 1 | 103 | 420 |
a | 90 | 20.9 | 21.1 | 29.7 | 0.71 | 102.8 | 288.9 |
b | 90 | 19.4 | 0 | 19.4 | 1 | 67.6 | 286.3 |
a | 135 | 4.2 | 12.9 | 13.5 | 0.31 | 102.8 | 131.6 |
b | 135 | 4 | 0 | 4 | 1 | 30.7 | 129.9 |
Simulation results table
Circuit type | TRIAC firing angle | Active power | Reactive power | Apparent power | power factor | Voltage | Current |
---|---|---|---|---|---|---|---|
⸰ | kW | kVar | kVA | V | A | ||
a | 0 | 48.4 | 0 | 48.4 | 1 | 220 | 220 |
b | 0 | 48.4 | 0 | 48.4 | 1 | 220 | 220 |
a | 90 | 24.2 | 15.4 | 34.2 | 0.71 | 220 | 155.6 |
b | 90 | 23.8 | 0 | 24.2 | 1 | 155.6 | 155.6 |
a | 135 | 4.4 | 7.7 | 14.6 | 0.3 | 220 | 66.3 |
b | 135 | 4.23 | 0 | 4.4 | 1 | 66.3 | 66.3 |