INFORMAZIONI SU QUESTO ARTICOLO

Cita

World Health Organization, “Nitrate and Nitrite in Drinking Water,” 2011. Search in Google Scholar

K. Tirumalesh, “Simultaneous determination of bromide and nitrate in contaminated waters by ion chromatography using amperometry and absorbance detectors,”Talanta, vol. 74, no. 5, pp. 1428–1434, 2008. Search in Google Scholar

M. A. M. Yunus, S. Ibrahim, W. Ali, H. Altowayti, and G. P. San, “Selective Membrane for Detecting Nitrate E ased on Planar Electromagnetic Sensors Array,” in Control Conference (ASCC), Asian, 2015, no. 4.10.1109/ASCC.2015.7244617 Search in Google Scholar

R. K. Mahajan, R. Kaur, H. Miyake, and H. Tsukube, “Zn(II) complex-based potentiometric sensors for selective determination of nitrate anion.,”Anal. Chim. Acta, vol. 584, no. 1, pp. 89–94, 2007.10.1016/j.aca.2006.11.011 Search in Google Scholar

C. Wardak, “Solid contact nitrate ion-selective electrode based on ionic liquid with stable and reproducible potential,”Electroanalysis, vol. 26, no. 4, pp. 864–872, 2014.10.1002/elan.201300590 Search in Google Scholar

M. A. M. Yunus and S. C. Mukhopadhyay, “Novel planar electromagnetic sensors for detection of nitrates and contamination in natural water sources,”IEEE Sens. J., vol. 11, no. 6, pp. 1440–1447, 2011. Search in Google Scholar

A. S. M. Nor, M. A. M. Yunus, S. W. Nawawi, and S. Ibrahim, “Low-cost sensor array design optimization based on planar electromagnetic sensor design for detecting nitrate and sulphate,”Proc. Int. Conf. Sens. Technol. ICST, pp. 693–698, 2013. Search in Google Scholar

T. K. Bera and J. Nagaraju, “Gold electrode sensors for Electrical Impedance Tomography (EIT) studies,”SAS 2011 - IEEE Sensors Appl. Symp. Proc., pp. 24–28, 2011.10.1109/SAS.2011.5739810 Search in Google Scholar

H. R. Lotfi Zadeh Zhad and R. Y. Lai, “Comparison of nanostructured silver-modified silver and carbon ultramicroelectrodes for electrochemical detection of nitrate,”Anal. Chim. Acta, vol. 892, pp. 153–159, 2015.10.1016/j.aca.2015.08.022 Search in Google Scholar

Y. Li, J. Sun, C. Bian, J. Tong, and S. Xia, “Procedia Engineering Electrodeposition of Copper Nano-clusters at a Platinum Microelectrode for Trace Nitrate Determination,”Procedia Eng., vol. 5, pp. 339–342, 2010.10.1016/j.proeng.2010.09.117 Search in Google Scholar

S. S. Hassan, “Ion-selective electrodes in organic functional group analysis: microdetermination of nitrates and nitramines with use of the iodide electrode.,”Talanta, vol. 23, no. 10, pp. 738–740, 1976.10.1016/0039-9140(76)80077-X Search in Google Scholar

S. S. M. Hassan, H. E. M. Sayour, and S. S. Al-Mehrezi, “A novel planar miniaturized potentiometric sensor for flow injection analysis of nitrates in wastewaters, fertilizers and pharmaceuticals,”Anal. Chim. Acta, vol. 581, no. 1, pp. 13–18, 2007.10.1016/j.aca.2006.08.011 Search in Google Scholar

B. Schnetger and C. Lehners, “Determination of nitrate plus nitrite in small volume marine water samples using vanadium(III)chloride as a reduction agent,”Mar. Chem., vol. 160, pp. 91–98, 2014.10.1016/j.marchem.2014.01.010 Search in Google Scholar

M. A. Ferree and R. D. Shannon, “Evaluation of a second derivative UV/visible spectroscopy technique for nitrate and total nitrogen analysis of wastewater samples,”Water Res., vol. 35, no. 1, pp. 327–332, 2001.10.1016/S0043-1354(00)00222-0 Search in Google Scholar

A. Lanoul, T. Coleman, and S. A. Asher, “UV resonance raman spectroscopic detection of nitrate and nitrite in wastewater treatment processes.,”Anal. Chem., vol. 74, no. 6, pp. 1458– 1461, 2002. Search in Google Scholar

D. Albanese, M. Di, and C. Alessio, “Screen printed biosensors for detection of nitrates in drinking water,” in 20th European Symposium on Computer Aided Process Engineering - ESCAPE20, 2010, vol. 28, pp. 283–288.10.1016/S1570-7946(10)28048-3 Search in Google Scholar

R. Michalski and I. Kurzyca, “Determination of Nitrogen Species ( Nitrate , Nitrite and Ammonia Ions ) in Environmental Samples by Ion Chromatography,”Polish J. Environ. Stud., vol. 15, no. 1, pp. 5–18, 2006. Search in Google Scholar

L. Zhang, M. Zhang, H. Ren, P. Pu, P. Kong, and H. Zhao, “Comparative investigation on soil nitrate-nitrogen and available potassium measurement capability by using solid-state and PVC ISE,”Comput. Electron. Agric., vol. 112, pp. 83–91, 2015.10.1016/j.compag.2014.11.027 Search in Google Scholar

M. A. M. Yunus, S. Mukhopadhyay, and A. Punchihewa, “Application of independent component analysis for estimating nitrate contamination in natural water sources using planar electromagnetic sensor,”2011 Fifth Int. Conf. Sens. Technol., vol. 1, pp. 538–543, 2011.10.1109/ICSensT.2011.6137037 Search in Google Scholar

M. O. Mendoza, E. P. Ortega, O. A. De Fuentes, Y. Prokhorov, and J. G. Luna, “Chitosan / bentonite nanocomposite : preliminary studies of its potentiometric response to nitrate ions in water,” pp. 7–10, 2014.10.1109/IBERSENSOR.2014.6995562 Search in Google Scholar

C. Li and L. Li, “Prediction of Nitrate and Chlorine in Soil Using Ion Selective Electrode,” in World Automation Congress (WAC), 2010, pp. 231–234. Search in Google Scholar

L. Nuñez, X. Cetó, M. I. Pividori, M. V. B. Zanoni, and M. del Valle, “Development and application of an electronic tongue for detection and monitoring of nitrate, nitrite and ammonium levels in waters,”Microchem. J., vol. 110, pp. 273–279, 2013.10.1016/j.microc.2013.04.018 Search in Google Scholar

T. A. Bendikov and T. C. Harmon, “A Sensitive Nitrate Ion-Selective Electrode An Analytical Laboratory Experiment,” vol. 82, no. 3, pp. 439–441, 2005.10.1021/ed082p439 Search in Google Scholar

A. Calvo-lópez, E. Arasa-puig, M. Puyol, J. Manel, and J. Alonso-chamarro, “Analytica Chimica Acta Biparametric potentiometric analytical microsystem for nitrate and potassium monitoring in water recycling processes for manned space missions,”Anal. Chim. Acta, vol. 804, pp. 190–196, 2013.10.1016/j.aca.2013.10.01324267081 Search in Google Scholar

E. Andreoli, V. Annibaldi, D. a Rooney, K.-S. Liao, N. J. Alley, S. a Curran, and C. B. Breslin, “Electrochemical Conversion of Copper-Based Hierarchical Micro/Nanostructures to Copper Metal Nanoparticles and Their Testing in Nitrate Sensing.,”Electroanalysis, vol. 23, no. 9, pp. 2164–2173, 2011. Search in Google Scholar

S. A. and S. Bhansali, “Development of Micro-Fluidic Nitrate-Selective Sensor Based On Polypyrrole Nanowires,”J. Chem. Inf. Model., vol. 53, pp. 1689–1699, 2013. Search in Google Scholar

F. Can, S. Korkut Ozoner, P. Ergenekon, and E. Erhan, “Amperometric nitrate biosensor based on Carbon nanotube/Polypyrrole/Nitrate reductase biofilm electrode,”Mater. Sci. Eng. C, vol. 32, no. 1, pp. 18–23, 2012.10.1016/j.msec.2011.09.00423177766 Search in Google Scholar

C. Li, Y Sun, J.Z Bian, “A Microfluidic Sensor Chip With Renewable In-Situ Copper Modified Microelectrode For Continuous Monitoring Of Nitrate,” in Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), International, 2011, pp. 2279–2282.10.1109/TRANSDUCERS.2011.5969232 Search in Google Scholar

Y. Li, J. Sun, C. Bian, J. Tong, and S. Xia, “A Micro Electrochemical Sensor with Porous Copper- clusters for Total Nitrogen Determination in Freshwaters,” in Nano/Micro Engineered and Molecular Systems (NEMS), 2013, vol. 1, pp. 1–4.10.1109/NEMS.2013.6559686 Search in Google Scholar

Y. Li, C. Bian, S. Xia, J. Sun, and J. Tong, “Micro electrochemical sensor with copper nanoclusters for nitrate determination in freshwaters,”Micro Nano Lett., vol. 7, no. 12, pp. 1197– 1201, 2012. Search in Google Scholar

H. Kodamatani, S. Yamazaki, K. Saito, T. Tomiyasu, and Y. Komatsu, “Selective determination method for measurement of nitrite and nitrate in water samples using high- performance liquid chromatography with post-column photochemical reaction and chemiluminescence detection,”J. Chromatogr. A, vol. 1216, no. 15, pp. 3163–3167, 2009. Search in Google Scholar

C. Lopez-Moreno, I. V. Perez, and A. M. Urbano, “Development and validation of an ionic chromatography method for the determination of nitrate, nitrite and chloride in meat,”Food Chem., vol. 194, pp. 687–694, 2016.10.1016/j.foodchem.2015.08.01726471608 Search in Google Scholar

M. R. Siddiqui, S. M. Wabaidur, Z. a. ALOthman, and M. Z. a. Rafiquee, “Rapid and sensitive method for analysis of nitrate in meat samples using ultra performance liquid chromatography–mass spectrometry,”Spectrochim. Acta Part A Mol. Biomol. Spectrosc., vol. 151, pp. 861–866, 2015.10.1016/j.saa.2015.07.02826184470 Search in Google Scholar

P. Niedzielski, I. Kurzyca, and J. Siepak, “A new tool for inorganic nitrogen speciation study: Simultaneous determination of ammonium ion, nitrite and nitrate by ion chromatography with post-column ammonium derivatization by Nessler reagent and diode-array detection in rain water samples,”Anal. Chim. Acta, vol. 577, no. 2, pp. 220–224, 2006.10.1016/j.aca.2006.06.05717723675 Search in Google Scholar

M. Akyüz and Ş. Ata, “Determination of low level nitrite and nitrate in biological, food and environmental samples by gas chromatography–mass spectrometry and liquid chromatography with fluorescence detection,”Talanta, vol. 79, no. 3, pp. 900–904, 2009.10.1016/j.talanta.2009.05.01619576462 Search in Google Scholar

Y. Li, J. S. Whitaker, and C. L. McCarty, “Reversed-phase liquid chromatography/electrospray ionization/mass spectrometry with isotope dilution for the analysis of nitrate and nitrite in water,”J. Chromatogr. A, vol. 1218, no. 3, pp. 476–483, 2011. Search in Google Scholar

Y. Zuo, C. Wang, and T. Van, “Simultaneous determination of nitrite and nitrate in dew, rain, snow and lake water samples by ion-pair high-performance liquid chromatography,”Talanta, vol. 70, no. 2, pp. 281–285, 2006.10.1016/j.talanta.2006.02.03418970764 Search in Google Scholar

A. Ayala, L. O. Leal, L. Ferrer, and V. Cerdà, “Multiparametric automated system for sulfate, nitrite and nitrate monitoring in drinking water and wastewater based on sequential injection analysis,”Microchem. J., vol. 100, no. 1, pp. 55–60, 2012.10.1016/j.microc.2011.09.004 Search in Google Scholar

M. Yaqoob, A. Nabi, and P. J. Worsfold, “Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection,”J. Chem. Soc. Pakistan, vol. 35, no. 2, pp. 533–539, 2013. Search in Google Scholar

M. Yaqoob, B. Folgado Biot, A. Nabi, and P. J. Worsfold, “Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection.,”Luminescence, vol. 27, no. 5, pp. 419–25, 2011.10.1002/bio.136623044772 Search in Google Scholar

S. Wang, K. Lin, N. Chen, D. Yuan, and J. Ma, “Talanta Automated determination of nitrate plus nitrite in aqueous samples with fl ow injection analysis using vanadium ( III ) chloride as reductant,”Talanta, pp. 1–5, 2015.10.1016/j.talanta.2015.06.03126695325 Search in Google Scholar

C. E. L. Pasquali, a. Gallego-Picó, P. F. Hernando, M. Velasco, and J. S. D. Alegría, “Two rapid and sensitive automated methods for the determination of nitrite and nitrate in soil samples,”Microchem. J., vol. 94, no. 1, pp. 79–82, 2010.10.1016/j.microc.2009.09.005 Search in Google Scholar

C. E. López Pasquali, P. Fernández Hernando, and J. S. Durand Alegría, “Spectrophotometric simultaneous determination of nitrite, nitrate and ammonium in soils by flow injection analysis,”Anal. Chim. Acta, vol. 600, no. 1–2 SPEC. ISS., pp. 177–182, 2007.10.1016/j.aca.2007.03.01517903481 Search in Google Scholar

S. Feng, M. Zhang, Y. Huang, D. Yuan, and Y. Zhu, “Simultaneous determination of nanomolar nitrite and nitrate in seawater using reverse flow injection analysis coupled with a long path length liquid waveguide capillary cell,”Talanta, vol. 117, pp. 456–462, 2013.10.1016/j.talanta.2013.09.042 Search in Google Scholar

P. S. Ellis, A. M. H. Shabani, B. S. Gentle, and I. D. McKelvie, “Field measurement of nitrate in marine and estuarine waters with a flow analysis system utilizing on-line zinc reduction,”Talanta, vol. 84, no. 1, pp. 98–103, 2011.10.1016/j.talanta.2010.12.028 Search in Google Scholar

A. D. Beaton, C. L. Cardwell, R. S. Thomas, V. J. Sieben, E. M. Waugh, P. J. Statham, M. C. Mowlem, and H. Morgan, “Lab-on-Chip Measurement of Nitrate and Nitrite for In Situ Analysis of Natural Waters,” 2012.10.1021/es300419u Search in Google Scholar

N. Amini and I. McKelvie, “An enzymatic flow analysis method for the determination of phosphatidylcholine in sediment pore waters and extracts,”Talanta, vol. 66, no. 2 SPEC. ISS., pp. 445–452, 2005.10.1016/j.talanta.2004.11.001 Search in Google Scholar

M. A. M. Yunus, S. C. Mukhopadhyay, and S. Ibrahim, “Planar Electromagnetic Sensor Based Estimation of Nitrate Contamination in Water Sources Using Independent Component Analysis,”IEEE Sens. J., vol. 12, no. 6, pp. 2024–2034, 2012. Search in Google Scholar

A. S. M. Nor, M. Faramarzi, M. A. M. Yunus, and S. Ibrahim, “Nitrate and Sulfate Estimations in Water Sources Using a Planar Electromagnetic Sensor Array and Artificial Neural Network Method,”IEEE Sens. J., vol. 15, no. 1, pp. 497–504, 2015.10.1109/JSEN.2014.2347996 Search in Google Scholar

M. A. M. Yunus and S. C. Mukhopadhyay, “Planar Electromagnetic Sensor for the Detection of Nitrate and Contamination in Natural Water Sources Using Electrochemical Impedance Spectroscopy,” in New Developments and Applications in Sensing Technology, 2011, pp. 39–63.10.1007/978-3-642-17943-3_3 Search in Google Scholar

M. A. M. Yunus and S. C. Mukhopadhyay, “Development of planar electromagnetic sensors for measurement and monitoring of environmental parameters,”Meas. Sci. Technol., vol. 22, no. 2, p. 025107, 2011. Search in Google Scholar

X. Wang, Y. Wang, H. Leung, S. C. Mukhopadhyay, M. Tian, and J. Zhou, “Mechanism and Experiment of Planar Electrode Sensors in Water Pollutant Measurement,”IEEE Trans. Instrum. Meas., vol. 64, no. 2, pp. 516–523, 2015.10.1109/TIM.2014.2340641 Search in Google Scholar

K. G. Ong, J. Wang, R. S. Singh, L. G. Bachas, and C. a Grimes, “Monitoring of bacteria growth using a wireless, remote query resonant-circuit sensor: application to environmental sensing.,”Biosens. Bioelectron., vol. 16, no. 4–5, pp. 305–12, 2001.10.1016/S0956-5663(01)00131-2 Search in Google Scholar

M. C. Hofmann, F. Kensy, J. Büchs, W. Mokwa, and U. Schnakenberg, “Transponderbased sensor for monitoring electrical properties of biological cell solutions,”J. Biosci. Bioeng., vol. 100, no. 2, pp. 172–177, 2005.10.1263/jbb.100.17216198260 Search in Google Scholar

S. Lakkis, R. Younes, Y. Alayli, and M. Sawan, “Review of recent trends in gas sensing technologies and their miniaturization potential,”Sens. Rev., vol. 34, no. 1, pp. 24–35, 2014.10.1108/SR-11-2012-724 Search in Google Scholar

M. R. Mahmoudian, Y. Alias, W. J. Basirun, P. Mengwoi, F. J. Sheini, and M. Sookhakian, “A sensitive electrochemical nitrate sensor based on polypyrrole coated palladium nanoclusters,”J. Electroanal. Chem., vol. 751, pp. 30–36, 2015.10.1016/j.jelechem.2015.05.026 Search in Google Scholar

M. Sohail, R. D. Marco, K. Lamb, and E. Bakker, “Thin layer coulometric determination of nitrate in fresh waters,”Anal. Chim. Acta, vol. 744, pp. 39–44, 2012.10.1016/j.aca.2012.07.02622935372 Search in Google Scholar

L. Yu, Q. Zhang, Q. Xu, D. Jin, G. Jin, K. Li, and X. Hu, “Electrochemical detection of nitrate in PM 2.5 with a copper-modified carbon fi ber micro-disk electrode,”Talanta, vol. 143, pp. 245–253, 2015.10.1016/j.talanta.2015.04.04926078156 Search in Google Scholar

T. Madasamy, M. Pandiaraj, and M. Balamurugan, “Biosensors and Bioelectronics Copper , zinc superoxide dismutase and nitrate reductase coimmobilized bienzymatic biosensor for the simultaneous determination of nitrite and nitrate,”Biosens. Bioelectron., vol. 52, no. 3, pp. 209–215, 2014.10.1016/j.bios.2013.08.03624055935 Search in Google Scholar

P. Ciosek and W. Wróblewski, “Potentiometric Electronic Tongues for Foodstuff and Biosample Recognition—An Overview,”Sensors, vol. 11, no. 12, pp. 4688–4701, 2011. Search in Google Scholar

B. Paczosa-bator, L. Cabaj, M. Raś, B. Baś, and R. Piech, “Potentiometric Sensor Platform Based on a Carbon Black Modified Electrodes,”Int. J. Electrochem. Sci., vol. 9, pp. 2816–2823, 2014. Search in Google Scholar

Z. Chang, Y. Zhu, L. Zhang, and S. Du, “Measurement Experiment and Mathematical Model of Nitrate Ion Selective Electrode,” in Third International Conference on Instrumentation, Measurement, Computer, Communication and Control, 2013, pp. 48–52.10.1109/IMCCC.2013.18 Search in Google Scholar

L. T. Duarte, C. Jutten, and S. Moussaoui, “A Bayesian Nonlinear Source Separation Method for Smart Ion-Selective Electrode Arrays,”IEEE Sens. J., vol. 9, no. 12, pp. 1763–1771, 2009. Search in Google Scholar

E. Santos, M. C. B. S. M. Montenegro, C. Couto, A. N. Araújo, M. F. Pimentel, and V. L. D. Silva, “Sequential injection analysis of chloride and nitrate in waters with improved accuracy using potentiometric detection,”Talanta, vol. 63, no. 3, pp. 721–727, 2004.10.1016/j.talanta.2003.12.03118969492 Search in Google Scholar

E. Lindner and B. D. Pendley, “A tutorial on the application of ion-selective electrode potentiometry: An analytical method with unique qualities, unexplored opportunities and potential pitfalls; Tutorial,”Anal. Chim. Acta, vol. 762, pp. 1–13, 2013.10.1016/j.aca.2012.11.02223327940 Search in Google Scholar

A. M. Stortini, L. M. Moretto, A. Mardegan, M. Ongaro, and P. Ugo, “Arrays of copper nanowire electrodes: Preparation, characterization and application as nitrate sensor,”Sensors Actuators B Chem., vol. 207, pp. 186–192, 2015.10.1016/j.snb.2014.09.109 Search in Google Scholar

T. Öznülüer, B. Özdurak, and H. Öztürk Doğan, “Electrochemical reduction of nitrate on graphene modified copper electrodes in alkaline media,”J. Electroanal. Chem., vol. 699, pp. 1–5, 2013.10.1016/j.jelechem.2013.04.001 Search in Google Scholar

I. S. da Silva, W. R. de Araujo, T. R. L. C. Paixão, and L. Angnes, “Direct nitrate sensing in water using an array of copper-microelectrodes from flat flexible cables,”Sensors Actuators B Chem., vol. 188, pp. 94–98, 2013.10.1016/j.snb.2013.06.094 Search in Google Scholar

K. Soropogui, M. Sigaud, and O. Vittori, “Alert Electrodes for Continuous Monitoring of Nitrate Ions in Natural Water,”Electroanalysis, vol. 18, no. 23, pp. 2354–2360, 2006. Search in Google Scholar

M. J. A. Shiddiky, M. S. Won, and Y. B. Shim, “Simultaneous analysis of nitrate and nitrite in a microfluidic device with a Cu-complex-modified electrode,”Electrophoresis, vol. 27, no. 22, pp. 4545–4554, 2006. Search in Google Scholar

T. R. L. C. Paixão, J. L. Cardoso, and M. Bertotti, “Determination of nitrate in mineral water and sausage samples by using a renewable in situ copper modified electrode,”Talanta, vol. 71, no. 1, pp. 186–191, 2007.10.1016/j.talanta.2006.03.040 Search in Google Scholar

W. Ren, S. Mura, and J. M. K. Irudayaraj, “Modified graphene oxide sensors for ultrasensitive detection of nitrate ions in water,”Talanta, vol. 143, pp. 234–239, 2015.10.1016/j.talanta.2015.05.073 Search in Google Scholar

W. Xuejiang, S. V. Dzyadevych, J. M. Chovelon, N. Jaffrezic, C. Ling, X. Siqing, and Z. Jianfu, “Conductometric nitrate biosensor based on methyl viologen / Nafion ® / nitrate reductase interdigitated electrodes,” vol. 69, pp. 450–455, 2006.10.1016/j.talanta.2005.10.014 Search in Google Scholar

Z. Zhang, S. Xia, D. Leonard, N. Jaffrezic-Renault, J. Zhang, F. Bessueille, Y. Goepfert, X. Wang, L. Chen, Z. Zhu, J. Zhao, M. G. Almeida, and C. M. Silveira, “A novel nitrite biosensor based on conductometric electrode modified with cytochrome c nitrite reductase composite membrane.,”Biosens. Bioelectron., vol. 24, no. 6, pp. 1574–9, 2009. Search in Google Scholar

D. Kirstein, L. Kirstein, F. Scheller, H. Borcherding, and J. Ronnenberg, “Amperometric nitrate biosensors on the basis of Pseudomonas stutzeri nitrate reductase,”J. Electroanal. Chem., vol. 474, pp. 43–51, 1999.10.1016/S0022-0728(99)00302-2 Search in Google Scholar

M. A. M. Yunus, V. Kasturi, S. C. Mukhopadhyay, and G. Sen Gupta, “Sheep Skin Property Estimation Using a Low-Cost Planar Sensor,” no. May, pp. 5–7, 2009.10.1109/IMTC.2009.5168497 Search in Google Scholar

C. Doyle, S. Campus, and C. Kerry, “A Cost-Effective and Accurate Electrical Impedance Measurement Circuit Design for Sensors,”Int. J. Sens. Intell. Syst., vol. 9, no. 2, pp. 509–525, 2016.10.21307/ijssis-2017-881 Search in Google Scholar

A. Larbi, B. Djedou, L. Bennacer, and B. M. Salah, “Towards a New Gas Sensor Microsystem Using Electroactive Polymers Thin Films,”Int. J. Sens. Intell. Syst., vol. 2, no. 3, pp. 448–462, 2009.10.21307/ijssis-2017-360 Search in Google Scholar

R. H. Bari, S. B. Patil, and A. R. Bari, “Synthesis , Characterization and Gas Sensing Performance Of Sol-Gel Prepared Nanocrystalline Sno 2 Thin Films,”Int. J. Sens. Intell. Syst., vol. 7, no. 2, pp. 610–629, 2014.10.21307/ijssis-2017-672 Search in Google Scholar

eISSN:
1178-5608
Lingua:
Inglese
Frequenza di pubblicazione:
Volume Open
Argomenti della rivista:
Engineering, Introductions and Overviews, other