The introduction of harmonious and spatially complex imaging with a simultaneous reduction of image speckles have contributed to significant advances in gallbladder ultrasonography. Furthermore, optimization of this technique was achieved by constructing high-resolution broadband transducers with 3D and 4D options for organ imaging. This diagnostic arsenal was further enriched with endoscopic, laparoscopic and contrast-enhanced ultrasound (CEUS), as well as elastography and automatic organ segmentation, which was achieved using a special algorithm(1–11). Ultrasonography has long been a method allowing for precise cytological diagnosis of lesions by means of transabdominal and endoscopic ultrasound-guided fine needle aspiration biopsy(12–14). Finally, the technique has gained acceptance as a treatment method for acute cholecystitis in patients disqualified from cholecystectomy by percutaneous or endoscopic aspiration of the infected content or by a temporary gallbladder drainage(14–16).
Digital ultrasonography with a variety of options to improve the image and different modes of color-coded blood flow is usually used in daily practice. In our opinion, the best protocol for gallbladder ultrasonography was presented by Hertzberg and Middleton, the authors of “Ultrasound: the requisites”(17). A comprehensive examination of this organ involves scanning in various positions (supine, prone, oblique and upright). This allows for almost complete visualization of gallbladder walls and content, as well as the mobility of lesions inside the gallbladder. In this paper, we would like to draw attention to some elements of gallbladder ultrasound, which may increase its diagnostic efficacy in everyday clinical practice, based on our own experience and the available literature.
To begin with, it seems important to specify which parts of the gallbladder are difficult to evaluate.
Figure 1 shows an optimal view of the gallbladder in two cross-sections in upright position. This image was obtained owing to the liver, which is an acoustic window for all parts of the gallbladder, including the fundus. The posterior wall of the gallbladder closely adheres to the duodenal bulb, which is filled with liquid in this case. The image may be unclear due to the presence of gas generating reflections in the gallbladder, which mimic biliary sludge. This acoustic effect also blurs the outline of the gallbladder wall in this region. Changing patient’s position allows for accessing the previously inaccessible wall segments (Fig. 2). A situation when the gallbladder fundus protrudes beyond the border of the liver is another common anatomical variant (Fig. 3). In such cases, when a convex transducer with a mean frequency of 3.5 MHz is used, the image of the gallbladder fundus becomes blurred and, consequently, lesions in this location may be overlooked. This is the most common location of focal adenomyomatosis, which is found in 1–9% of cholecystectomy specimens(18). Our observations indicate that ultrasonography often fails to detect this type of pathology at this site (Fig. 4 A and Fig. 4 B). A linear 7–12 MHz transducer allows for obtaining a clearer image of the gallbladder fundus in patients without overweight or adiposity (Fig. 5 and Fig. 6). Significant diagnostic difficulties occur in the case of pathological lesions located in the neck region in patients with a large anteroposterior epigastric size. Imaging improvement may be expected after moving the focus to the ROI (Fig. 7). However, it should be kept in mind that the cystic duct may be long and tortuous, which will pose a real challenge in such cases (Fig. 8). Horizontal position of the gallbladder at the level of the costal arch will pose another imaging difficulty (Fig. 9). This is a situation when the gallbladder walls are positioned least favorably, i.e. parallel to the ultrasound beam. This will require applying the transducer at different sites along with adjusting patient’s position and the optimal level of breath hold.
Pseudolesions due to adherence of neighboring organs are another issue to discuss. The duodenal bulb may sometimes protrude into the gallbladder fundus, thereby mimicking a solid tumor, a liquid lesion or a stone (Fig. 10)(19). In this situation, it is worth resuming gallbladder assessment as the bulb may shrink during this time and expose the fundus. In the case of further doubts, an intake of a glass of water by the patient helps resolve the situation. The presence of fluid, often accompanied by duodenal gas, ultimately helps make a correct diagnosis.
The transverse colon filled with gas or stool may also mimic stones in the gallbladder fundus. Gas collections in the intestine cause the so-called dirty acoustic shadow. If this occurs, the transducer should be positioned in the long axis of the intestine, contributing to the visualization of the haustration of the transverse colon (Fig. 11).
The examples in section 1 indicate that a reliable measurement of the thickness of the gallbladder wall is only possible in the hepatic wall. It is advisable to measure it on an enlarged sonogram using the zoom function (Fig. 12).
The measurements are often performed using images obtained with a convex transducer (usually in one cross-section), especially in the case of polyps. This is not a precise method, as documented in Fig. 13. In such cases, it is worth zooming the image to assess the lesion in two dimensions (Fig. 14). Effort should be made to visualize the lesion in the largest possible dimensions as polypoid formations may be multi-shaped (Fig. 15). This is important due to the management strategy in gallbladder polyps. Resection is recommended for polyps ≥10 mm as they significantly increase the risk of dysplasia or cancer(2–4,20,21). An enlarged image allows tracking the polyp’s behavior over time with greater precision. According to Sun
Each detected gallbladder lesion should be assessed for mobility as this allows for accurate diagnosis in most cases. Mobility is typically shown by deposits, a mass of biliary sludge, parasites and gas. A typical supine or left oblique position may be associated with difficulties in detecting microcholelithiasis adhering to the wall adjacent to the duodenum, which is often filled with gas generating bright reflections. Right oblique position is useful in such cases. This allows for visualizing small deposits on the hepatic background and for a more reliable estimation of their number (Fig. 16 A and Fig. 16 B).
Another issue associated with gallstones in the gallbladder is their behavior depending on body position during scanning. Cholesterol stones account for a vast majority, i.e. 75%, of biliary stones. Since their specific gravity is lower than that of bile, they migrate to the fundus of the gallbladder, which is often the highest part of this organ, when in upright position. Figure 17 shows gallbladder stone migration upon changing patient’s position from a supine to upright position. Providing this information to patients should prevent them from lying down within an hour after a meal to avoid stone migration into the neck upon shrinking of the gallbladder. This relationship between stone location and body position is a common cause of biliary colic in the evening or at night.
Changes in position can even affect the gallbladder itself, which results from its faulty attachment to the liver (Fig. 18 A and Fig. 18 B). A mobile gallbladder, which is also referred to as a floating gallbladder, will be prone to torsion. This complication usually occurs in emaciated, elderly females. This is a serious life-threatening condition(22–24).
The introduction of high-sensitivity blood flow imaging methods is an additional important factor supporting gallbladder ultrasound diagnosis. The degree of vascularization of lesions detected in the gallbladder and its walls should be assessed in various pathologies during each examination. Color Doppler should be set at slow blood flow, i.e. 2–10 cm/s2.
This modality is recommended in the following situations:
assessment of the degree of gallbladder wall congestion and/or ischemia in cholecystitis(25);
differentiation between pseudopolyps and true polyps (it is often possible to visualize vasculature in the latter(26)) (Fig. 19);
detecting pathological vascularization in gallbladder cancer and invaded tissues(26–28) (Fig. 20);
diagnosis of gallbladder varices(29–31) (Fig. 21 A and Fig. 21 B);
visualization of a twinkling artifact in focal adenomyomatosis of the gallbladder(1,26) (Fig. 4 B and Fig. 6);
differentiation between a mass of biliary sludge and a solid tumor in the gallbladder(26);
attempt to locate the site of gallbladder perforation(32).
The issues presented in this paper are only a fraction of problems faced by an ultrasound operator in the field of gallbladder diagnostic imaging. However, the proposed ultrasound approaches should help solve some of these problems in everyday practice.