INFORMAZIONI SU QUESTO ARTICOLO

Cita

Fig. 1

Echolucent areas with color flow
Echolucent areas with color flow

Fig. 2

Diagnostic accuracy of the total number of echolucent zones (blue), total number of echolucent zones with color flow (yellow), and the largest size of echolucent zones (green) in predicting morbidly adherent placenta using ROC curve analysis
Diagnostic accuracy of the total number of echolucent zones (blue), total number of echolucent zones with color flow (yellow), and the largest size of echolucent zones (green) in predicting morbidly adherent placenta using ROC curve analysis

Comparison of the two study groups regarding the number of vessels in the placenta, size and number of echolucent zones with/without color flow at different sites

Variables Patients with morbidly adherent placenta (mean ± SD) Patients without morbidly adherent placenta (mean ± SD) P value
Size of the largest echolucent areas at the fetal surface (mm) 21.3 ± 8.1 15.42 ± 11.68 0.001
Size of the largest echolucent areas at the non-fetal surface (mm) 19.4 ± 7.04 9.21 ± 10.64 <0.001
Size of the largest echolucent areas extended to both surfaces (mm) 21 ± 15.3 7.77 ± 14.41 <0.001
Size of the largest echolucent areas enclosed in placenta (mm) 16.93 ± 7.34 11.63 ± 7.60 0.01
Size of the largest echolucent area at any site (mm) 29.4 ± 8.4 21.66 ± 12.83 0.004
Number of echolucent areas at the fetal surface 4.86 ± 2.89 2.49 ± 2.08 <0.001
Number of echolucent areas at the non-fetal surface 3.53 ± 3.39 1.11 ± 1.29 <0.001
Number of echolucent areas extended to both surfaces 1.0 ± 0.84 0.40 ± 0.87 0.001
Number of echolucent areas enclosed in placenta 9.06 ± 2.40 5.10 ± 4.26 <0.001
Total number of intraplacental echolucent areas* 18.40 ± 6.78 9.12 ± 6.45 <0.001
Number of echolucent areas with flow at the fetal level 1.86 ± 1.55 0.06 ± 0.28 <0.001
Number of echolucent areas with flow at the non-fetal level 1.4 ± 1.24 0.08 ± 0.39 0.01
Number of echolucent areas with flow extended to both surfaces 0.73 ± 0.70 0.04 ± 0.25 <0.001
Number of echolucent areas with flow enclosed in placenta 4.33 ± 5.12 0.06 ± 0.31 <0.001
Total number of intraplacental echolucent areas with flow* 7 ± 3.6 0.24 ± 0.76 <0.001
Number of vessels in placenta 5.53 ± 1.68 2.39 ± 2 <0.001

Sensitivity and specificity of echolucent areas in predicting morbidly adherent placenta

Variables Amount Sensitivity Specificity
Total number of intraplacental echolucent areas with flow >2 0.93 0.98
Total number of intraplacental echolucent areas >13 0.86 0.80
Size of the largest echolucent area in non-fetal part >11 0.93 0.66
eISSN:
2451-070X
Lingua:
Inglese
Frequenza di pubblicazione:
4 volte all'anno
Argomenti della rivista: