INFORMAZIONI SU QUESTO ARTICOLO
Pubblicato online: 06 lug 2017
Pagine: 212 - 215
Ricevuto: 16 dic 2016
DOI: https://doi.org/10.1515/jee-2017-0031
Parole chiave
© 2017 Faculty of Electrical Engineering and Information Technology, Slovak University of Technology
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
This paper discusses the problem of reliability of the Polish medium voltage power lines. It presents the benchmarking of power lines and values of SAIDI. The probability density distribution of the medium voltage lines length as well as selected indicators of the MV power lines reliability, being operated by the distribution companies under test, are also introduced. The analysis is based on the actual MV lines and uses the nonparametric method of kernel density estimation.