Editorials
Résumé
Articles
- Accès libre
Comparison of cardiac time intervals between echocardiography and impedance cardiography at various heart rates
Pages: 2 - 8
Résumé
The non-invasively measured initial systolic time interval (ISTI) reflects a time difference between the electrical and pumping activity of the heart and depends on cardiac preload, afterload, autonomic nervous control and training level. However, the duration of the ISTI has not yet been compared to other time markers of the heart cycle. The present study gauges the duration of the ISTI by comparing the end point of this interval, the C-point, with heart cycle markers obtained by echocardiography. The heart rate of 16 healthy subjects was varied by means of an exercise stimulus. It was found that the C-point, and therefore the end point of ISTI, occurred around the moment of the maximum diameter of the aortic arch in all subjects and at all heart rates. However, while the time difference between the opening of the aortic valves and the maximum diameter of the aortic arch decreased significantly with decreasing RR-interval, the time difference with respect to the moment of the C-point remained constant within the subjects. This means that the shortening of the ISTI with increasing heart rate in response to an exercise stimulus was caused by a shortening of the pre-ejection period (PEP). It is concluded that the ISTI can be used as a non-invasive parameter indicating the time difference between the electrical and mechanical pumping activity of the heart, both inside and outside the clinic.
Mots clés
- Impedance cardiography
- ISTI
- echocardiography, preload
- autonomic nervous control
- PEP
- heart cycle
- Accès libre
Simplified estimation of membrane potentials induced by high-frequency electric signals
Pages: 9 - 13
Résumé
In this paper we show why the poorly conducting cytoplasmic membranes have little effect on the overall impedance of the tissue above a certain frequency, and derive an estimate of this upper frequency. It is further shown that the induced transmembrane potentials at different sites over the membrane can be found through a simple formula for frequencies above the threshold, without the need to analytically or theoretically model the membranes directly. The findings are validated for an irregular cell shape through rigorous numerical modeling.
Mots clés
- Cytoplasm Membranes
- Numerical Modeling
- Trans-membrane Potential
- High Frequencies
- Accès libre
Electrical bioimpedance spectroscopy in time-variant systems: Is undersampling always a problem?
Pages: 28 - 33
Résumé
During the last decades, Electrical Bioimpedance Spectroscopy (EBIS) has been applied mainly by using the frequency-sweep technique, across a range of many different applications. Traditionally, the tissue under study is considered to be time-invariant and dynamic changes of tissue activity are ignored by treating the changes as a noise source. A new trend in EBIS is simultaneous electrical stimulation with several frequencies, through the application of a multi-sine, rectangular or other waveform. This method can provide measurements fast enough to sample dynamic changes of different tissues, such as myocard. This high sampling rate comes at a price of reduction in SNR and the increase in complexity of devices. Although the frequency-sweep technique is often inadequate for monitoring the dynamic changes in a variant system, it can be used successfully in applications focused on the time-invariant or slowly-variant part of a system. However, in order to successfully use frequency-sweep EBIS for monitoring time-variant systems, it is paramount to consider the effects of aliasing and especially the folding of higher frequencies, on the desired frequency e.g. DC level. This paper discusses sub-Nyquist sampling of thoracic EBIS measurements and its application in the case of monitoring pulmonary oedema. It is concluded that by considering aliasing, and with proper implementation of smoothing filters, as well as by using random sampling, frequency-sweep EBIS can be used for assessing time-invariant or slowly-variant properties of time-variant biological systems, even in the presence of aliasing. In general, undersampling is not always a problem, but does always require proper consideration.
Mots clés
- Electrical bioimpedance spectroscopy
- Aliasing in thoracic impedance spectroscopy
- frequency-sweep EBIS
- Thoracic Impedance Measurements
- sub-Nyquist sampling
- Accès libre
Electrical characterization of bolus material as phantom for use in electrical impedance and computed tomography fusion imaging
Pages: 34 - 39
Résumé
Phantoms are widely used in medical imaging to predict image quality prior to clinical imaging. This paper discusses the possible use of bolus material, as a conductivity phantom, for validation and interpretation of electrical impedance tomography (EIT) images. Bolus is commonly used in radiation therapy to mimic tissue. When irradiated, it has radiological characteristics similar to tissue. With increased research interest in CT/EIT fusion imaging there is a need to find a material which has both the absorption coefficient and electrical conductivity similar to biological tissues. In the present study the electrical properties, specifically resistivity, of various commercially available bolus materials were characterized by comparing their frequency response with that of
Mots clés
- Bolus
- Electrical Impedance Tomography
- CT
- Tissue Electrical Properties
- Accès libre
Isoconductivity method to study adhesion of yeast cells to gold electrode
Pages: 40 - 47
Résumé
In this paper, we used impedance spectroscopy and gold electrodes to detect the presence of yeast cells and monitor the attachment of these cells to the electrodes. We analyzed the effect of conductivity changes of the medium and the attachment on the electrode-electrolyte interface impedance. A three-electrode cell was designed to produce a uniform electric field distribution on the working electrode and to minimize the counter electrode impedance. Moreover, we used a small AC overpotential (10 mV) to keep the system within the linear impedance limits of the electrode-electrolyte interface. This study proposes a new method to differentiate the impedance changes due to the attachment of yeast cells from those due to conductivity changes of the medium. The experiments showed that when the difference between the cell suspension and base solution conductivities is within the experimental error, the impedance changes are only due to the attachment of yeast cells to the electrodes. The experiments also showed a strong dependence (decrease) of the parallel capacity of the electrode electrolyte interface with the yeast cell concentration of suspension. We suggest that this decrease is due to an asymmetrical redistribution of surface charges on both sides of cell, which can be modeled as a biologic capacity connected in series with the double layer capacity of the interface. Our results could help to explain the rate of biofilm formation through the determination of the rate of cell adhesion.
Mots clés
- Electrode electrolyte interface
- yeast
- attachment
- impedance
- frequency
- Accès libre
Impedance Ratio Method for Urine Conductivity-Invariant Estimation of Bladder Volume
Pages: 48 - 54
Résumé
Non-invasive estimation of bladder volume could help patients with impaired bladder volume sensation to determine the right moment for catheterisation. Continuous, non-invasive impedance measurement is a promising technology in this scenario, although influences of body posture and unknown urine conductivity limit wide clinical use today. We studied impedance changes related to bladder volume by simulation, in-vitro and in-vivo measurements with pigs. In this work, we present a method to reduce the influence of urine conductivity to cystovolumetry and bring bioimpedance cystovolumetry closer to a clinical application.
Mots clés
- Impedance tomography
- cystovolumetry
- volume estimation
- Accès libre
Transient bioimpedance monitoring of mechanotransduction in artificial tissue during indentation
Pages: 55 - 73
Résumé
Mechanotransduction is of fundamental importance in cell physiology, facilitating sensing in touch and hearing as well as tissue development and wound healing. This study used an impedance sensor to monitor the effective resistance and permittivity of artificial tissues, alginate hydrogel with encapsulated fibroblasts, which were kept viable through the use of a bespoke microfluidic system. The observed transient impedance responses upon the application of identical compressive normal loads differed between acellular hydrogels and hydrogels in which fibroblasts were encapsulated. These differences resulted from changes in the conductivity and permeability of the hydrogel due to the presence of the encapsulated fibroblasts, and transient changes in ion concentrations due to mechanotransduction effects.
Mots clés
- Bioimpedance
- mechanotransduction
- restitution
- cells
- artificial skin
- tissue engineering
- Accès libre
Biomass measurement of living Lumbriculus variegatus with impedance spectroscopy
Pages: 92 - 98
Résumé
Impedance spectroscopy is a useful tool for non-invasive and real time measurements of cell suspensions and a variety of biological tissues. The objective of this study was the investigation of the dielectric properties of living aquatic worms (
Mots clés
- impedance spectroscopy
- worm biomass
- in situ measurement
- Accès libre
The feasibility of using compression bioimpedance measurements to quantify peripheral edema
Pages: 99 - 109
Résumé
The accurate assessment of body fluid volume is important in many clinical situations, especially in the determination of “dry weight” in a dialysis setting. Currently, no clinically applicable diagnostic system exists to determine the mechanical properties that accurately characterize peripheral edema in an objective and quantitative manner. We have developed a method for quantifying the impact of compression on the electrical properties of tissue by measuring stress-induced changes in bioimpedance (BIS). Using this method, we simultaneously measured the impedance and mechanical response of a tissue mimicking material (tofu) under both quasi-static and dynamic loading conditions. Our results demonstrate a temporal quantification of viscoelastic properties using a viscoelastic phantom tissue model.
Mots clés
- Bioimpedance
- peripheral edema
- dry weight
- tissue compression
- tofu
- Accès libre
Modelling the Ability of Rheoencephalography to Measure Cerebral Blood Flow
Pages: 110 - 113
Résumé
Despite the long history of rheoencephalography (REG), some important aspects of the method are still debatable. Bioimpedance measurements offer great potential benefit for study of the human brain, but the traditional four or six electrode method suffers from potential misinterpretations and lack of accuracy. The objective of this paper is to study the possible mechanism of REG formation by means of numerical modelling using a realistic finite element model of the human head. It is shown that the cardiac related variations in electrical resistivity of the scalp contributes more than 60% to the REG amplitude, whereas the brain and cerebrospinal fluid are mutually compensated by each over.
Mots clés
- Rheoenchephalography
- finite element model
- numerical modelling
Reviews
- Accès libre
A short tutorial contribution to impedance and AC-electrokinetic characterization and manipulation of cells and media: Are electric methods more versatile than acoustic and laser methods?
Pages: 74 - 91
Résumé
Lab-on-chip systems (LOCs) can be used as
Mots clés
- Mixing equation
- single-shell model
- travelling wave
- electro-osmosis
- micropump
- induced transmembrane potential
- RC model
- influential radius
- Maxwell's equivalent body
Tutorial Articles
Résumé
This paper gives a basic overview of relevant statistical methods for the analysis of bioimpedance measurements, with an aim to answer questions such as: How do I begin with planning an experiment? How many measurements do I need to take? How do I deal with large amounts of frequency sweep data? Which statistical test should I use, and how do I validate my results? Beginning with the hypothesis and the research design, the methodological framework for making inferences based on measurements and statistical analysis is explained. This is followed by a brief discussion on correlated measurements and data reduction before an overview is given of statistical methods for comparison of groups, factor analysis, association, regression and prediction, explained in the context of bioimpedance research. The last chapter is dedicated to the validation of a new method by different measures of performance. A flowchart is presented for selection of statistical method, and a table is given for an overview of the most important terms of performance when evaluating new measurement technology.
Mots clés
- Statistics
- research methodology
- bioimpedance
- data analysis
- data reduction
- parameterization
- prediction
- classification
- performance
- validation