A Simple Procedure to Determine Complex Permittivity of Moist Materials Using Standard Commercial Coaxial Sensor
, , , et
08 avr. 2011
À propos de cet article
Publié en ligne: 08 avr. 2011
Pages: 19 - 22
DOI: https://doi.org/10.2478/v10048-011-0003-4
Mots clés
This content is open access.
A simple procedure was developed to determine complex permittivity of moist materials for known percentage of moisture content at any frequency based using a standard commercial coaxial sensor. Polynomial fitting and Gaussian elimination method were applied to obtain a single equation of complex permittivity as a function of frequency and moisture content. The empirical equation was tested for new samples and was found to have mean error percentage of 5.14 % and 10.22 % for dielectric constant and loss factor, respectively, when compared to a commercial probe.