Accès libre

Comparison of Intubation Success Rate using Airtraq Laryngoscope and Intubating Laryngeal Mask Airway in Novice Users with Prior Airway Management Experience: A Prospective Randomised Study

À propos de cet article

Citez

Figure 1

CONSORT Flow diagram.
CONSORT Flow diagram.

Figure 2

Different shapes of pilot balloon.
Different shapes of pilot balloon.

Comparison of demographic variables in both groups

Patient characteristics Group A Group I P value
female: male 12:17 11:18 1.00
Age (years) 35.26 ± 11 35.5 ± 11 0.93
Weight (Kg) 57.23 ± 7.61 59 ± 6.91 0.35
ASA I/II [n] 24/6 23/7 1.00
MP I/II/III/IV [n] 16/10/4/0 11/12/5/2 0.35

Grading of sorethroat

Score Description
0 No complaints or evidence of sore throat or hoarseness
1 Patient complaints of minimal sore throat but observer found no hoarseness when compared with preoperative quality of voice
2 Patient complaints of moderate sore throat or observer found moderate hoarseness
3 Patient complaints of severe sore throat or observer found marked hoarseness.

Comparison of Intubation Characteristics in successful intubations between both groups

Parameters A (n = 24) I (n = 30) P value
T in seconds (mean ±SD) 45.37 ± 27.55 77.6 ± 31.85 0.0003
T in A, T2 in I (mean±SD) 45.37 ± 27.55 33.06 ± 19.07 0.058
Ease of intubation (VAS median [IQR]) 5 [4–6] 5 [4–7] 0.533
Number of attempts (1/2) 19/5 26/4 0.489
Number of adjusting maneuvers (0/1/2) 11/12/1 13/15/2 0.91