Innovative Hybrid War Strategy Optimization with Incremental Conductance for Maximum Power Point Tracking in Partially Shaded Photovoltaic Systems
Catégorie d'article: Research paper
Publié en ligne: 21 déc. 2024
Pages: 1 - 18
Reçu: 18 sept. 2024
Accepté: 15 nov. 2024
DOI: https://doi.org/10.2478/pead-2025-0001
Mots clés
© 2025 Hechmi Khaterchi et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
Although solar energy can be intermittent, it has become a preferred option due to its low carbon emissions, large-scale production potential, and ability to be integrated into various energy systems. The conversion into electricity is achieved using photovoltaic (PV) systems, which are utilized in various applications, including residential use, water pumping, electric vehicles, and grid-connected configurations (Adel et al., 2019; Alharthi et al., 2021; Khatib and Muhsen, 2020). However, optimizing the energy output from PV systems presents challenges due to the non-linear electrical characteristics (current–voltage) of PV cells, which are influenced by weather conditions such as radiation and temperature. To maximize energy extraction, a maximum power point tracking (MPPT) algorithm is employed to effectively solve this optimization problem.
Numerous studies have addressed the challenge of identifying the optimal operating point to maximize energy extraction from PV modules using different MPPT methods. Among the most widely used are the perturb and observe (P&O) (Manna and Akella, 2021; Salman et al., 2018) and incremental conductance (IC) MPPT controllers (Abd et al., 2019; Shang et al., 2020). These classical methods are simple, easy to implement, and generally effective in tracking the maximum power point (MPP) under normal conditions. However, they suffer from drawbacks such as continuous oscillations around the MPP and slow convergence when there are sudden changes in temperature or irradiation, which can lead to a significant power loss during steady-state conditions. Additionally, these classical methods are ineffective in handling the issue of partial shading conditions (PSCs) (Ko et al., 2020).
In recent years, several advanced control methods have been proposed to address the limitations of classical MPPT techniques. These include sliding mode control (SMC)-based MPPT algorithms (Zhang et al., 2022), backstepping controllers (Chennoufi et al., 2021), grey wolf optimization (GWO) (Guo et al., 2020), and various optimization algorithms such as ant colony optimization (ACO) (Priyadarshi et al., 2019), particle swarm optimization based on radial basis function algorithm (PSO-RBF) (Hamdi et al., 2019), flower pollination algorithm (FPA) (De et al., 2021), glow worm swarm optimization (Jin et al., 2017), Cuckoo search algorithm (CSA) (Abo-Elyousr et al., 2020), and artificial bee colony (ABC) (González-Castaño et al., 2021). A particle swarm optimization (PSO)-based MPPT technique is proposed for efficient global maximum power point tracking (GMPP) under partial shading conditions (Brahmi, M. et al., 2022). While these methods have demonstrated improved MPP tracking capabilities, they also introduce increased system complexity and have not fully resolved the challenges caused by partial shading (Ahmed, 2022; Sagonda and Folly, 2022).
All these methods ensure global convergence, but they have major drawbacks such as long response times and low tracking efficiency. Additionally, they require significant computational time and resources to achieve satisfactory results (Ali et al., 2022; Ibrahim et al., 2023) proposed a new modified hybrid particle swarm optimization proportional–integral–derivative (MPSO-PID) with an anti-windup strategy based on MPPT. The results demonstrate the robustness and effectiveness of the proposed strategies in improving the performance of particle swarm optimization (PSO) and PV systems. However, the MPSO-PID hybrid needs to be compared with other optimization algorithms to reduce ripple content and improve the efficiency of the PV installation. In this context, an efficient MPPT method based on a modified version of the hybrid war strategy optimization-incremental conductance (WSO-IC) algorithm is proposed to track the MPP in the PV system. The main contribution of this method is to enhance the hybrid algorithm by utilizing the strengths of the WSO metaheuristic algorithm and the adaptive IC heuristic algorithm to accelerate convergence to the MPP, reduce output power oscillation, and minimize power losses.
Moosavi et al. (2022) proposed a new MPPT control approach for PV systems based on the dynamic group-based cooperation optimization (DGBCO) algorithm. The DGBCO reduces tracking time by up to 60%, achieving a tracking efficiency of 99.86% under both dynamic and steady-state conditions, and provides a 2% to 8% increase in harvested energy compared to other conventional techniques. In our simulations, the WSO-IC method also achieves comparable tracking efficiency, ranging between 99.4% and 99.9%, and offers a similar increase, particularly under PSCs.
In addition, to demonstrate the superiority and robustness of the proposed hybrid WSO-IC, the results obtained are compared with the following conventional MPPT controllers: the classic (P&O) MPPT controller and the original MPPT algorithms (IC and WSO). The contributions of the method presented in this article are summarized as follows: A new MPPT controller based on a hybrid WSO-IC has been proposed, ensuring a faster response time with minimal power losses and minimal oscillation around the MPP. The proposed Maximum Power Point Tracking (MPPT) control algorithm performs more reliably and effectively, even when there are fixed or steady partial shading conditions (PSCs) on the photovoltaic system. Real-time simulation and a comparison study of the proposed MPPT control based on WSO-IC are performed using MATLAB/Simulink.
The motivation behind the hybridization of WSO and IC lies in overcoming the limitations inherent in each individual algorithm when applied to MPPT in PV systems. The IC algorithm, while effective in precisely tracking the MPP by analysing the local gradient of the power curve, can be slow to converge, especially under static PSCs. Moreover, the IC method exhibits remarkable oscillations around the MPP, which can lead to power loss. Conversely, the WSO algorithm excels in global optimization by exploring a broad search space. However, WSO alone may not provide the necessary precision in converging to the exact MPP due to its reliance on population-based heuristics. By integrating WSO with IC, the hybrid algorithm leverages the global search capability of WSO and the local fine-tuning ability of IC, resulting in a more efficient and robust MPPT solution in static PSCs.
The main novelty of our work lies in the development of a hybrid MPPT controller that combines the strengths of the WSO algorithm with the IC method. While classical MPPT techniques, such as P&O and IC, have proven effective under normal conditions, they face challenges due to the complexities introduced by partial shading. Our approach addresses these limitations by leveraging the global optimization capabilities of WSO while benefiting from the local tracking precision of IC, resulting in a more robust and effective solution for maximizing energy production in PV systems.
In particular, our hybrid WSO-IC algorithm improves convergence speed toward the MPP while significantly reducing output power oscillations and energy losses, especially under static PSCs. The results indicate impressive tracking efficiency, ranging from 99.4% to 99.9%, demonstrating its superiority over conventional methods. Additionally, we provide real-time simulations using MATLAB/Simulink, comparing our hybrid algorithm with traditional controllers, thus reinforcing the efficiency and robustness of our method. In summary, our contributions include:
A new MPPT controller that combines WSO and IC to enhance performance in PSCs. Significant improvements in response time, reduction of power losses, and minimization of oscillations around the MPP. Comprehensive validation through comparative studies with established MPPT techniques, reinforcing the applicability and efficiency of the method in real-world scenarios.
The organization of the article is structured as follows:
Section 2—The PV Conversion Chain: Description and Modelling: This section covers the modelling of solar cells, static boost converters, and the impact of partial shading on PV systems. Section 3—Hybrid WSO-IC Algorithm for MPPT: This section explores the IC and WSO algorithms, introduces the hybrid WSO-IC approach, and discusses its advantages. Section 4—Simulation Results and Statistical Analysis: This section presents the simulated outcomes and a comprehensive statistical analysis of the proposed methods. Section 5—Conclusion: The concluding section summarizes the main contributions and highlights future research directions.
The MPP is reached by controlling a DC–DC converter using a MPPT controller, as illustrated in Figure 1. The MPPT controller optimizes the transfer of power from the PV installation to the load under different weather conditions.

General PV conversion chain. PV, photovoltaic.
The PV installation consists of two identical panels connected in series, with their electrical characteristics provided in Table 1.
Electrical specifications of the PV panels.
Pmax | Voc | Isc | Vmp | Imp | |
---|---|---|---|---|---|
PV module | 213.15 W | 36.3 V | 7.84 A | 29 V | 7.35 A |
PV installation | 426.3 W | 72.6 V | 7.84 A | 58 V | 7.35 A |
Imp, output current at the MPP under STC; Isc, short circuit current under STC; Pmax, maximum power output under STC; PV, photovoltaic; STC, standard test conditions; Vmp, voltage at the MPP under STC; Voc, open circuit voltage under STC.
The electrical parameters of the DC–DC boost converter used in simulation are listed in Table 2.
Electrical specifications of the boost converter.
Parameter | Noun | Value |
---|---|---|
Boost converter | ||
Inductance (mH) | 1.1478 | |
Input capacitor ( |
6,800 | |
Output capacitor ( |
3,300 | |
PWM frequency (kHz) | 10 | |
Load | ||
Resistive load (Ω) | 100 |
PWM, pulse width modulation.
The components of the boost converter play a critical role in the system’s operation and directly influence the performance of the WSO-IC algorithm. The inductance (
A PV cell is described by the single-diode model. This model is generalized to a PV module by considering it as a set of identical cells connected in series and/or in parallel. A model of an elementary cell is constructed based on the most commonly used equivalent electrical circuit, as illustrated in Figure 2 (Drif et al., 2024).

Equivalent circuit diagram of solar cell.
A PV system is made up of several PV modules that are electrically connected in series (
The DC–DC converter plays a vital role in implementing MPPT within PV systems. MPPT algorithms typically work in tandem with the DC–DC converter to optimize system performance and maximize energy conversion efficiency under fluctuating operating conditions. A boost converter, for instance, is a type of DC–DC converter that increases the output voltage above the input level (Regaya et al., 2020). The power generated by the PV panel is directed to this boost converter, which is regulated by a pulse–width modulation (PWM) signal from the MPPT controller.
The duty cycle (
As detailed in previous research (Chrouta et al., 2023; Kumar and Gupta, 2012), the optimal duty cycle of the DC–DC boost converter, which makes it possible to extract the maximum power generated by the PVG, is given by the following relationship:
The MPPT block generates a duty cycle signal, which controls the switching device of the boost converter, operating at a frequency of 10 kHz. The choice of a boost converter is driven by the PV system’s need for a higher output voltage, thus requiring a voltage step-up. Additionally, the selection of a boost converter is influenced by its reputation as one of the simplest and most easily controllable types of DC–DC converters, as indicated by Eltamaly et al. (2020).
Considering the continuous conduction mode (CCM) and selecting the current through the inductor and the voltage across the capacitor as state variables, the averaged model of the boost converter, shown in Figure 1, can be defined in Eqs (7) and (8) (Manuel and İnanç, 2022; Menadi et al., 2024).
During no uniform irradiance conditions, such as those caused by the shadow of a tree, building, or passing clouds, the PVG system becomes partially shaded. When partial shading occurs, regardless of the cause, as illustrated in Figure 3, the power–voltage (P–V) curves display multiple peaks corresponding to MPPs. Among these peaks, only one is the global maximum power point (GMPP), while the others are local maximum power points (LMPP).

Configuration of PV modules under different static PSCs. (A) Scenario 1—STC. (B) Scenario 2. (C) Scenario 3. (D) Scenario 4. PSCs, partial shading conditions; PV, photovoltaic; STC, standard test conditions.
PV panels receive varying irradiance levels to simulate PSCs, which can lead to PV curves with multiple peaks. To highlight our contribution, we present a case study of static PSCs featuring four practical test scenarios for simulation:
Scenario 1: A test under standard conditions (1,000 W/m2 and 25°C); Scenario 2: Static partial shading with Ir1 = 1,000 W/m2, Ir2 = 400 W/m2 at 25°C; Scenario 3: Static partial shading with Ir1 = 800 W/m2, Ir2 = 400 W/m2 at 25°C; Scenario 4: Static partial shading with Ir1 = 600 W/m2, Ir2 = 400 W/m2 at 25°C.
Simulations were conducted using MATLAB/Simulink to explore and evaluate the effectiveness of the hybrid WSO-IC algorithm for achieving optimal performance under the proposed static partial shading scenarios. The simulation results were compared with those obtained from the two traditional MPPT methods: P&O and IC.
MPPT is a crucial technique used in PV systems to ensure that the system operates at its maximum efficiency. The purpose of MPPT is to find the optimal operating point on the PV curve, where the product of voltage and current (which equals power) is maximized. Given the non-linear characteristics of PV systems and the variability of environmental conditions, sophisticated algorithms are required to dynamically adjust the operating point.
In comparison, hybrid metaheuristic algorithms combine the strengths of multiple optimization techniques, often yielding more accurate and robust MPPT, especially in complex scenarios like partial shading. These hybrid methods can adapt to varying conditions more effectively but are generally more complex to implement than the IC algorithm.
The IC algorithm is an MPPT technique used in PV systems to optimize energy extraction by calculating and comparing the instantaneous conductance (dI/dV) with the voltage. It continuously adjusts the operating voltage to maintain operation near the MPP with reduced oscillations, offering a balance between simplicity and efficiency. However, its accuracy can be compromised by noise and partial shading.
The IC algorithm adjusts the duty cycle
Expanding this gives:
1: 2: 3: 4: Measure current voltage Vpv and current Ipv 5: Calculate the change in voltage: ΔV = Vpv −Vpv prev 6: Calculate the change in current: ΔI = Ipv −Ipv prev 7: 8: 9: Decrease duty cycle: D = Dprev −ΔD 10: 11: Increase duty cycle: D = Dprev +ΔD 12: 13: No change in duty cycle: D = Dprev 14: 15: 16: 17: Decrease duty cycle: D = Dprev −ΔD 18: 19: 20: Update previous values: Vpv prev = Vpv, Ipv prev = Ipv 21: 22:
At the MPP, the output power of the PV system is maximized, which implies that any small change in voltage (
The IC algorithm adjusts the duty cycle
This ensures a rapid response to changes in the PV system’s operating conditions.
The IC algorithm is a widely used MPPT technique that relies on the observation that at the MPP, the derivative of power with respect to voltage (dP/dV) is zero. The IC method calculates the instantaneous change in PV voltage (
WSO is a metaheuristic algorithm inspired by military strategies. It operates on a population of candidate solutions, each representing a potential duty cycle
Key steps in WSO include:
Initialization: Initialize a population of candidate solutions. Fitness Evaluation: Calculate the fitness of each candidate. Update Rules: Adjust candidate positions using:
Convergence Check: Iterate until the optimal solution is found or a maximum number of iterations is reached.
The operation of this algorithm is described in the flowchart in Figure 4.

Flowchart of WSO algorithm. WSO, war strategy optimization.
WSO is a metaheuristic algorithm inspired by military strategies. It is modelled as an optimization process wherein each soldier dynamically moves towards the optimum value. In the context of MPPT, WSO is employed to refine the search for the optimal duty cycle (
The hybrid WSO-IC algorithm is an advanced technique that combines the advantages of IC and WSO. It is designed to swiftly and efficiently identify the GMPP of a PV system under static PSCs, minimizing response time and enhancing overall system performance. This hybrid approach offers both fast convergence and high accuracy in tracking the MPP, making it a robust solution for PV systems.
Key steps in hybrid WSO-IC include:
1: 2: 3: 4: 5: Measure current voltage Vpv and current Ipv 6: Calculate the change in voltage: ΔV = Vpv −Vpv prev 7: Calculate the change in current: ΔI = Ipv −Ipv prev 8: 9: 10: D = Dprev −ΔD 11: 12 D = Dprev +ΔD 13: 14: D = Dprev 15: 16: 17: D = Dprev −ΔD 18: 19: Constrain D within [0,0.95] 20: Update previous values: Vpv prev = Vpv, Ipv prev = Ipv and Dprev = D 21: 22: Calculate fitness value: fitness = −Vpv ×Ipv ×D 23: Update WSO positions and fitness values 24: Adjust positions based on best and global best solutions 25: Constrain positions within [0,0.95] 26: Check for convergence criteria 27: 28: Output the optimal duty cycle D for MPPT
The operation of this algorithm is described in the flowchart given in Figure 5.

Flowchart of hybrid WSO-IC Algorithm. WSO-IC, war strategy optimization-incremental conductance.
The benefits of the hybrid WSO-IC algorithm can be outlined in the following four main points:
A series of simulation tests were carried out on the proposed MPPT control algorithm. The simulation has been realized under the MATLAB/Simulink environment using the control scheme illustrated in Figure 6.

Diagram of the 426.3 W peak power PV system simulated in SIMULINK. PV, photovoltaic.
The DC–DC boost converter serves as an interface between the simulated PV installation and a simulated DC load, with the entire system being modelled in the simulation environment. The boost converter is used to control the operating point for current and voltage, thus facilitating the acquisition of the true MPP. In this setup, four different MPPT algorithm blocks are integrated into various sections, with each MPPT method being simulated in succession.
The primary objective of this work is to study and conduct a comparative analysis of four different algorithms for tracking the GMPP of a PV system under the influence of static partial shading. The algorithms considered are IC, P&O, WSO, and a hybrid WSO-IC algorithm. The proposed hybrid WSO-IC algorithm is utilized to further refine the search method in order to accurately track the exact location of the GMPP.
We selected the four algorithms: P&O, IC, WSO, and WSO-IC for comparison due to their complementary approaches in MPPT. P&O is widely used for its simplicity, while IC offers greater precision, especially under changing irradiance conditions. WSO was included as it is an effective global optimization method, particularly useful under PSCs. The hybrid WSO-IC combines the strengths of WSO and IC, aiming to enhance both tracking speed and accuracy. Regarding power losses in the DC–DC converter, these depend to some extent on the control algorithm. More efficient tracking algorithms can reduce oscillations around the MPP, thereby minimizing switching losses and improving overall system efficiency. Algorithms that are slow to converge or prone to oscillations can cause increased switching activity and higher losses in the converter.
The comparative performance analysis of the four algorithms involves observing three parameters to evaluate the tracking time, tracking error, and efficiency of the studied PV system.
The second parameter,
Optimal duty cycle calculated for each scenario
Scenario | D_opt | |
---|---|---|
Scenario 1 | D_opt_G = |
|
Scenario 2 | D_opt_G = |
|
D_opt_L = 0.54699656 | ||
Scenario 3 | D_opt_G = |
|
D_opt_L = 0.77950357 | ||
Scenario 4 | D_opt_G = |
|
D_opt_L = 0.74620251 |
D_opt_G: Optimal duty cycle corresponding to global peak point using Eq. (6).
D_opt_L: Optimal duty cycle corresponding to local peak point using Eq. (6).
The third parameter assesses the
The simulation results are presented in Figures 7–10, corresponding respectively to the power Ppv and duty cycle for the four scenarios 1, 2, 3, and 4 of each of the four algorithms: IC, P&O, WSO, and WSO-IC. The x-axis is consistent across all four cases in each scenario, with a scale ranging from 0 s to 4 s.

Power Ppv and duty cycle under standard conditions (Scenario 1-STC). STC, standard test conditions.

Power Ppv and duty cycle under PSCs (Scenario 2). PSCs, partial shading conditions.

Power Ppv and duty cycle under PSCs (Scenario 3). PSCs, partial shading conditions.

Power Ppv and duty cycle under PSCs (Scenario 4). PSCs, partial shading conditions.
In the four scenarios 1, 2, 3 and 4, the comparative performance of the hybrid WSO-IC method is demonstrated in Figures 7–10. Remarkably, this method quickly reaches the GMPP with a minimal tracking error in the duty cycle and a high efficiency in extracting the maximum power from the PV installation compared to other methods such as IC, P&O, and WSO. Notably, this objective is achieved without encountering persistent oscillations in the steady state. On the other hand, the WSO method exhibits a faster response time than the other algorithms.
The data collected during the simulation phase allowed for the calculation of the tracking error percentage in the global duty cycle for each method, as indicated in Table 4.
Comparison of algorithm performance across different scenarios
Algorithm | Convergence time (ms) | Duty cycle | Tracking error (%) | Ppv (w) | Efficiency (%) |
---|---|---|---|---|---|
Scenario 1: Ir1 = Ir2 = 1000 W/m2, T1 = T2 = 25 C, |
|||||
IC | 648.689 | 0.7103 | 0.9641 | 426.130 | 99.96 |
P&O | 628.276 | 0.7108 | 0.8943 | 426.124 | 99.96 |
WSO | 352.368 | 0.7101 | 0.9919 | 426.106 | 99.95 |
398.437 | 0.7116 | 426.148 | |||
Scenario 2: Ir1 = 1000 W/m2, Ir2 = 400 W/m2, T1 = T2 = 25 C, |
|||||
IC | 768.902 | 0.5305 | 34.0041 | 189.453 | 91.35 |
P&O | 517.483 | 0.5308 | 33.9668 | 189.450 | 91.35 |
WSO | 254.545 | 0.7925 | 1.4105 | 204.705 | 98.70 |
271.329 | 0.7938 | 207.356 | |||
Scenario 3: Ir1 = 800 W/m2, Ir2 = 400 W/m2, T1 = T2 = 25 C, |
|||||
IC | 567.832 | 0.7704 | 39.9145 | 167.000 | 89.02 |
P&O | 405.594 | 0.7699 | 39.8236 | 167.200 | 89.13 |
WSO | 271.329 | 0.7714 | 40.0961 | 167.200 | 89.13 |
442.281 | 0.5313 | 187.600 | |||
Scenario 4: Ir1 = 600 W/m2, Ir2 = 400 W/m2, T1 = T2 = 25 C, |
|||||
IC | 623.776 | 0.7401 | 34.2933 | 125.800 | 68.15 |
P&O | 433.566 | 0.7400 | 34.2752 | 125.900 | 68.20 |
WSO | 338.462 | 0.7391 | 34.1119 | 125.700 | 68.09 |
492.350 | 0.5378 | 184.500 |
IC, incremental conductance; P&O, perturb and observe; WSO, war strategy optimization; WSO-IC, war strategy optimization-incremental conductance.
The results clearly show that the WSO-IC outperforms the other suggested approaches in various aspects. Notably, it excels in accurately tracking the global duty cycle (GMPP) and in its ability to operate at its maximum power. The efficiency of the WSO-IC method ranges between 0.995 and 1.000 in the four scenarios studied.
The results shown in Table 4 and Figure 11 underscore the effectiveness of the WSO-IC method in optimizing the MPPT process for PV systems. The superior convergence speed and efficiency percentage of this method highlight its potential as an essential choice for optimizing energy production and overcoming shading challenges in PV applications.

Quantitative comparison between the performances of IC, P&O, WSO, and WSO-IC methods for different shading patterns. (A) Duty cycle tracking error and (B) power extraction efficiency. IC, incremental conductance; P&O, perturb and observe; WSO, war strategy optimization; WSO-IC, war strategy optimization-incremental conductance.
The hybrid approach, which integrates IC and WSO, is designed to capitalize on the strengths of both methods. The IC algorithm facilitates a quicker initial convergence to a region near the MPP, while WSO fine-tunes the search to ensure the attainment of the global MPP, particularly in partial shading scenarios. Although WSO performs well on its own, incorporating IC aims to decrease the overall duty cycle tracking error and enhance efficiency—key factors for the system’s performance. To comprehensively evaluate the performance of the proposed WSO-IC MPPT controller compared to other methods, a set of key performance indicators (KPIs) was used. These KPIs, detailed in Table 5, include:
Performance comparison of the proposed WSO-IC with different MPPT algorithms
MPPT algorithm | Efficiency (%) | Tracking time (s) |
---|---|---|
P&O (Khatib and Muhsen, 2020) | 96.08 | |
FL (Khatib and Muhsen, 2020) | 96.94 | 0.35 |
PSO (Khatib and Muhsen, 2020) | 99.62 | 0.50 |
GWO (Berttahar et al., 2024) | 97.08 | 0.78 |
HOA (Berttahar et al., 2024) | 99.76 | 0.33 |
0.398 |
FL, fuzzy logic, GWO, grey wolf optimization; MPPT, maximum power point tracking; P&O, perturb and observe; PSO, particle swarm optimization; HOA, horse herd optimization algorithm; WSO-IC, war strategy optimization-incremental conductance.
The results presented in Table 5 clearly indicate that the WSO-IC algorithm outperforms other methods in several key areas. Based on the simulation obtained data, the percentage efficiency for each method was calculated. It is evident that the WSO-IC method achieves significantly higher efficiency compared to the techniques discussed by Khatib and Muhsen (2020) and Berttahar et al. (2024). The WSO-IC controller also shows a faster response time compared to PSO by Khatib and Muhsen (2020) and GWO by Berttahar et al. (2024) under static PSCs, indicating its ability to quickly achieve the GMPP. This leads to reducing ‘uncaptured’ energy, which our method achieves by reaching the GMPP faster with high efficiency.
These results highlight the effectiveness and the superiority of WSO-IC in optimizing the MPPT process for PV systems. The enhanced convergence speed and efficiency percentage of WSO-IC make it a promising choice for optimizing power generation and addressing shading challenges in PV applications.
This research conducted an in-depth exploration of various MPPT techniques, emphasizing their essential role in optimizing the efficiency of PV systems. By evaluating both individual and hybrid MPPT algorithms, we provided valuable insights into their performance under different operational conditions. The study focused on key parameters such as cost, complexity, response time, stability, performance under partial shading, and accuracy, offering a holistic view of the effectiveness of these techniques. Among the conventional and intelligent MPPT controllers examined, the hybrid WSO-IC algorithm consistently demonstrated superior performance. It effectively addresses the limitations of classical MPPT methods such as IC and P&O, which often suffer from instability, oscillations, and slower convergence, particularly under fluctuating weather conditions. The WSO-IC algorithm excels in achieving faster convergence to the MPP with minimal oscillations, thereby maximizing energy harvest. While the WSO-IC algorithm incurs higher costs compared to traditional methods, its enhanced efficiency and robustness make it a compelling choice for advanced PV systems. The study also highlighted that other hybrid techniques, such as P&O combined with PSO, show commendable performance, though WSO-IC remains the most effective overall. In conclusion, the WSO-IC algorithm stands out as a highly efficient and reliable solution for MPPT in PV systems, offering a balance between performance and cost. Its ability to maintain high efficiency even under challenging conditions makes it a strong contender for large-scale solar energy applications. Future research should focus on further refining this hybrid approach and validating its performance in real-world scenarios, aiming to enhance the global adoption of solar energy.
For further studies, we suggest adjusting key parameters to optimize performance across various GPV (photovoltaic generator) architectures, possibly using advanced optimization techniques. Additionally, testing the method under different environmental conditions, such as variations in irradiance, temperature, and shading, will help evaluate its robustness. Testing on real equipment would provide deeper insights into practical performance. Finally, the development of adaptive control strategies that adjust parameters in real time based on environmental changes would further enhance the applicability of our approach to a broader range of configurations.
We suggested broadening the application of this method to additional configurations to assess its versatility and effectiveness in various scenarios. Specifically, we aim to implement the methodology in centralized, decentralized, and hybrid PV systems, as well as with different types of solar panels, including monocrystalline and polycrystalline varieties. Additionally, we plan to evaluate the algorithm under a range of conditions, such as varying irradiance levels and dynamic partial shading situations. By applying the methodology across these different system designs and environmental contexts, we seek to enhance our understanding of its performance and potential adaptations.
As part of our future projects, we are considering several initiatives to explore the applicability of the WSO-IC algorithm in more complex configurations of PV systems. We plan to apply our method to decentralized PV systems, where multiple modules are distributed across a site and interact to maximize collective energy production. We also intend to explore solar tracking systems, where the WSO-IC algorithm could be integrated to optimize energy capture in real time, based on the position of the sun. Finally, testing in real-world environments with dynamic shading scenarios and fluctuating irradiance levels will further validate our approach under varied operating conditions, thereby strengthening the robustness and relevance of our method for practical applications.