Ergot alkaloids (EAs) are toxic substances naturally produced by
Ergot alkaloids were extracted with acetonitrile, and dispersive solid phase extraction (d-SPE) was used for clean-up of the extracts. After evaporation, the extracts were reconstituted in ammonium carbonate and acetonitrile and subjected to instrumental analysis using high-performance liquid chromatography with fluorescence detection. The developed method was validated in terms of linearity, selectivity, repeatability, reproducibility, robustness, matrix effect, limits of quantification and detection and uncertainty. The EA content of 40 compound feeds was determined.
All the assessed validation parameters fulfilled the requirements of Regulation (EU) 2021/808. At least one of the monitored alkaloids was determined in 40% of the samples. The EAs with the highest incidence rate were ergocryptine, ergometrinine and ergocornine. The total concentrations of EAs ranged from under the limit of quantification to 62.3 μg kg−1.
The results demonstrated that the developed method was suitable for simultaneously determining twelve EAs in compound feed and could be used for routine analysis.