New method of analysis of nitrofurans and nitrofuran metabolites in different biological matrices using UHPLC-MS/MS
Publié en ligne: 07 juil. 2018
Pages: 161 - 166
Reçu: 21 févr. 2018
Accepté: 11 juin 2018
DOI: https://doi.org/10.2478/jvetres-2018-0025
Mots clés
© 2018 Tomasz Śniegocki et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Introduction
The major difficulty in analysis of nitrofurans in feed, feed water, and food of animal origin is that nitrofurans have low molecular weights and fast metabolism. The principal goal of this study was to prepare a procedure for the determination of nitrofurans and their metabolites by a single method in different types of feed, feed water, and food of animal origin.
Material and Methods
Two-gram samples were subjected to hydrolysis and derivatisation processes by addition of hydrochloric acid and 2-nitrobenzaldehyde. After incubation the sample was purified by solid phase extraction technique. Nitrofurans were analysed using ultra-high-pressure liquid chromatography-MS/MS (UHPLC-MS/MS).
Results
The results of validation fulfil the requirement of the confirmatory criteria according to the European Commission Decision 2002/657/EC regarding apparent recoveries (88.9%–107.3%), repeatability (2.9%–9.4%) and within-laboratory reproducibility (4.4%–10.7%).
Conclusion
The method can be successfully applied to monitor nitrofurans and their metabolites in different matrices.