Accès libre

Improving sensitivity in the deep regions of a volume conductor using electrical focused impedance methods

 et   
06 sept. 2024
À propos de cet article

Citez
Télécharger la couverture

Morucci JP, Rigaud B. Bioelectrical impedance techniques in medicine part III: Impedance imaging third section: Medical applications. Critical Reviews in Biomedical Engineering. 24(4-6);655-677:1996. https://doi.org/10.1615/CritRevBiomedEng.v24.i4-6.60 Morucci JP. Rigaud B. Bioelectrical impedance techniques in medicine part III: Impedance imaging third section: Medical applications . Critical Reviews in Biomedical Engineering . 24 ( 4-6 ); 655 677 : 1996 . https://doi.org/10.1615/CritRevBiomedEng.v24.i4-6.60 Search in Google Scholar

Rabbani KS, Kadir MA. Possible applications of Focused Impedance Method (FIM) in biomedical and other areas of study. Bangladesh Journal of Medical Physics. 4(1);67-74: 2011. https://doi.org/10.3329/bjmp.v4i1.14689 Rabbani KS Kadir MA . Possible applications of Focused Impedance Method (FIM) in biomedical and other areas of study . Bangladesh Journal of Medical Physics . 4 ( 1 ); 67 74 : 2011 . https://doi.org/10.3329/bjmp.v4i1.14689 Search in Google Scholar

Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Physics in Medicine & Biology. 41(11);2251:1996. https://doi.org/10.1088/0031-9155/41/11/002 Gabriel S Lau RW Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz . Physics in Medicine & Biology . 41(11);2251:1996. https://doi.org/10.1088/0031-9155/41/11/002 Search in Google Scholar

Khalil SF, Mohktar MS, Ibrahim F. The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases. Sensors. 14(6); 10895-10928: 2014. https://doi.org/10.3390/s140610895 Khalil SF Mohktar MS Ibrahim F. The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases . Sensors. 14(6; 10895-10928: 2014. https://doi.org/10.3390/s140610895 Search in Google Scholar

Thomasset A. Bio-electric properties of tissues. Estimation by measurement of impedance of extracellular ionic strength and intracellular ionic strength in the clinic. Lyon Médical. 209; 1325-1350:1963. Thomasset A. Bio-electric properties of tissues. Estimation by measurement of impedance of extracellular ionic strength and intracellular ionic strength in the clinic . Lyon Médical . 209 ; 1325 1350 : 1963 . Search in Google Scholar

Lingwood BE, Colditz PB, Ward, LC. Biomedical applications of electrical impedance analysis. In ISSPA'99. Proceedings of the Fifth International Symposium on Signal Processing and its Applications (IEEE Cat.No. 99EX359). 1; 367-370:1999. https://doi.org/10.1109/ISSPA.1999.818188 Lingwood BE Colditz PB Ward LC. Biomedical applications of electrical impedance analysis. In ISSPA'99 . Proceedings of the Fifth International Symposium on Signal Processing and its Applications (IEEE Cat.No. 99EX359) . 1 ; 367 370 : 1999 . https://doi.org/10.1109/ISSPA.1999.818188 Search in Google Scholar

Martinsen ØG, Grimnes S. The concept of transfer impedance in bioimpedance measurements. In 4th European Conference of the International Federation for Medical and Biological Engineering. 1078-1079:2009 (pp. 1078-1079). https://doi.org/10.1007/978-3-540-89208-3_257 Martinsen ØG Grimnes S. The concept of transfer impedance in bioimpedance measurements . In 4th European Conference of the International Federation for Medical and Biological Engineering . 1078 1079 : 2009 (pp. 1078-1079). https://doi.org/10.1007/978-3-540-89208-3_257 Search in Google Scholar

Rabbani KS, Sarker M, Akond M, Akter T. Focused impedance measurement (FIM): a new technique with improved zone localization. Annals of the New York Academy of Sciences. 873;408-420:1999. https://doi.org/10.1111/j.1749-6632.1999.tb09490.x Rabbani KS Sarker M Akond M Akter T. Focused impedance measurement (FIM): a new technique with improved zone localization . Annals of the New York Academy of Sciences . 873 ; 408 420 : 1999 . https://doi.org/10.1111/j.1749-6632.1999.tb09490.x Search in Google Scholar

Rabbani KS, Karal MA. A new four-electrode Focused Impedance Measurement (FIM) system for physiological study. Annals of Biomedical Engineering. 36(6);1072-1077: 2008. https://doi.org/10.1007/s10439-008-9470-7 Rabbani KS Karal MA. A new four-electrode Focused Impedance Measurement (FIM) system for physiological study . Annals of Biomedical Engineering . 36 ( 6 ); 1072 1077 : 2008 . https://doi.org/10.1007/s10439-008-9470-7 Search in Google Scholar

Rabbani KS. Focused Impedance Method: Basics and Applications. In: Simini F., Bertemes-Filho P. (eds) Bioimpedance in Biomedical Applications and Research. Springer, Cham; 2018 pp. 137-185. https://doi.org/10.1007/978-3-319-74388-2_9. Rabbani KS. Focused Impedance Method: Basics and Applications . In: Simini F. Bertemes-Filho P. (eds) Bioimpedance in Biomedical Applications and Research . Springer , Cham ; 2018 pp. 137 185 . https://doi.org/10.1007/978-3-319-74388-2_9 . Search in Google Scholar

Islam N, Rabbani KS, Wilson AJ. The sensitivity of focused electrical impedance measurements, Physiological Measurement. 31;S97-S109:2010. https://doi.org/10.1088/0967-3334/31/8/s08 Islam N Rabbani KS Wilson AJ. The sensitivity of focused electrical impedance measurements, Physiological Measurement . 31 ; S97 S109 : 2010 . https://doi.org/10.1088/0967-3334/31/8/s08 Search in Google Scholar

Rabbani KS. Simple electrode configurations for probing deep organs using Electrical Bio-Impedance techniques. Bangladesh Journal of Medical Physics. 11(1);1-5:2019. https://doi.org/10.3329/bjmp.v11i1.44053 Rabbani KS. Simple electrode configurations for probing deep organs using Electrical Bio-Impedance techniques . Bangladesh Journal of Medical Physics . 11 ( 1 ); 1 5 : 2019 . https://doi.org/10.3329/bjmp.v11i1.44053 Search in Google Scholar

Mobarak M, Rabbani KS. Improving the sensitivity at the center of lung by using Focused Impedance Method. SEU Journal of Science and Engineering. 13(1):2019. Mobarak M Rabbani KS. Improving the sensitivity at the center of lung by using Focused Impedance Method . SEU Journal of Science and Engineering . 13 ( 1 ): 2019 . Search in Google Scholar

Mobarak M, Rabbani KS. Improving deep sensitivity of Four-Electrode Focused Impedance Method in lungs by varying electrode geometries. Bangladesh Journal of Medical Physics. 15(1);43-54:2022. https://doi.org/10.3329/bjmp.v15i1.63561 Mobarak M Rabbani KS. Improving deep sensitivity of Four-Electrode Focused Impedance Method in lungs by varying electrode geometries . Bangladesh Journal of Medical Physics . 15 ( 1 ); 43 54 : 2022 . https://doi.org/10.3329/bjmp.v15i1.63561 Search in Google Scholar

Roy SK, Karal MA, Kadir MA, Rabbani KS. A new six-electrode electrical impedance technique for probing deep organs in the human body. European Biophysics Journal. 48(8);711-719:2019. https://doi.org/10.1007/s00249-019-01396-x Roy SK Karal MA Kadir MA Rabbani KS. A new six-electrode electrical impedance technique for probing deep organs in the human body . European Biophysics Journal . 48 ( 8 ); 711 719 : 2019 . https://doi.org/10.1007/s00249-019-01396-x Search in Google Scholar

Khanal T, Rabbani KS. Sensitivity study of a locally developed six electrode focused impedance method. Journal of Electrical Bioimpedance. 15(1);33-40:2024. https://doi.org/10.2478/joeb-2024-0005 Khanal T Rabbani KS. Sensitivity study of a locally developed six electrode focused impedance method . Journal of Electrical Bioimpedance . 15 ( 1 ); 33 40 : 2024 . https://doi.org/10.2478/joeb-2024-0005 Search in Google Scholar

Mobarak M, Kadir MA, Rabbani KS. Probing deep lung regions using a new 6-electrode tetrapolar impedance method. Journal of Electrical Bioimpedance. 13(1);116-124:2022. https://doi.org/10.2478/joeb-2022-0016 Mobarak M Kadir MA Rabbani KS. Probing deep lung regions using a new 6-electrode tetrapolar impedance method . Journal of Electrical Bioimpedance . 13 ( 1 ); 116 124 : 2022 . https://doi.org/10.2478/joeb-2022-0016 Search in Google Scholar

Haque R, Kadir MA, Rabbani KS. Probing for stomach using the Focused Impedance Method (FIM). Journal of Electrical Bioimpedance. 10(1);73-82:2019. https://doi.org/10.2478/joeb-2019-0011 Haque R Kadir MA Rabbani KS. Probing for stomach using the Focused Impedance Method (FIM) . Journal of Electrical Bioimpedance . 10 ( 1 ); 73 82 : 2019 . https://doi.org/10.2478/joeb-2019-0011 Search in Google Scholar

Grimnes S, Martinsen ØG. Bioelectricity and bioimpedance basics. 2nd edition. Academic Press. Grimnes S Martinsen ØG. Bioelectricity and bioimpedance basics . 2nd edition . Academic Press . Search in Google Scholar