1. bookVolume 14 (2023): Edition 1 (January 2023)
Détails du magazine
License
Format
Magazine
eISSN
1891-5469
Première parution
01 Jan 2010
Périodicité
1 fois par an
Langues
Anglais
Accès libre

A renewed challenge to electrical bioimpedance: rapid assessment of pathogenic bacteria

Publié en ligne: 02 Mar 2023
Volume & Edition: Volume 14 (2023) - Edition 1 (January 2023)
Pages: 1 - 2
Reçu: 23 Jan 2023
Détails du magazine
License
Format
Magazine
eISSN
1891-5469
Première parution
01 Jan 2010
Périodicité
1 fois par an
Langues
Anglais

I was fortunate to meet Professor Herman Paul Schwan a couple of times. Unforgettable scenes took place during the X ICEBI, held in Barcelona back in April 1998. At the end of most presentations, in a gentle and elegant manner, Professor Schwan used to highlight that similar studies (mostly more advanced ones!) were previously performed by himself together with other emblematic figures of the field. Hence gaining new insights into an electrical bioimpedance (EB) topic appears highly challenging if not erroneous.

However, recent technological advancements concerning both instrumentation and data analysis as well as combining EB with other methods led to sensitive quantitative tools to assess bacteria, and the related antimicrobial susceptibility testing (AST), bringing the topic of Rapid Assessment of Pathogenic Bacteria back into a well-deserved spotlight.

The first electrical impedance assay to assess microorganism growth was described at the end of the 19th Century (Stewart, 1899) [1]. The analytical concept relates to an indirect route to appraise the increasing microbial density of a sample by monitoring the electrical conductivity of the growth medium modified by the microbial metabolism.

Since electrical assays lack specificity, EB microbial assessments are generally affected by low throughput, lengthy assays, have to be performed on previously isolated cultures or in conjunction with a method allowing target microbe separation from the sample. High-throughput, automation and specificity are nowadays enabled via immunomagnetic capturing and combination with magnetophoresis and microfluidics.

Microbial identification, and quantitation as well as rapid AST can be achieved based on EB in conjunction with periodic magnetophoresis, as reported by my group [2,3]. Microbial immunomagnetic capture of the target pathogens out of the clinical bio-samples [3] is performed in conjunction with EB measurements to assess the formation of aggregates of magnetically tagged microbes (AMbM) and provide microbial identification, as well.

EB measurements are simultaneously performed at two radiofrequencies chosen to assess the impedance decrement (related to the beta dispersion) of magnetically tagged live microbes to derive the electrical opacity of the specimen as the ratio of impedance amplitude at the higher versus the one at lower frequency (see also [4]).

EB monitoring of the AMbMs periodic magnetophoresis between two electrodes allows quantitative assessment of microbial load (quantitation) since microbial load relates to the weight of the electrode coverage by AMbMs [2].

Bacterial viability is revealed by electrical opacity of the magnetically tagged microbes (membrane integrity is a marker of cell viability). Since susceptibility/resistance to bactericidal antimicrobials directly relates to microbial viability, EB provides an effective tool for cost effective AST assays.

Besides the suitability to multiplexing, allowing AST of various antimicrobials be performed in parallel, such assays allow for rapid measurements since a relevant amount of magnetically trapped microbial cells could be simultaneously analyzed.

Examples based on microfluidic impedance cytometry were recently reported by Hywel’s group [4] in which simultaneous measurements at two radiofrequencies are also deployed to assess the antibiotic induced alteration via cellular 2-D plots showing electrical size vs. electrical opacity.

While the whole (magnetically tagged) bacterial population can be addressed at once, single cell EB analysis cannot be attained due to the limited spatial resolution of the electrical assays, inherently linked to the electrode size.

Thus, another game changer is provided by combining EB and optical methods e.g., by AC electrically modulated light microscopy assays, as the ones highlighted by recent reports [5,6].

These approaches empower EB assays with the spatial resolution needed to allow single cell analysis without the limitations related to electrode size and microelectrode arrays dimensionality. Single-cell resolution is currently limited to analysis of cells adhered to the sensing electrode, yet access to (the dynamics of) of both electrical and the complementary optical parameters of cellular structures is expected to provide new insights into living cell machinery. These advancements are expected to open up renewed challenges to Electrical Bioimpedance supporting countless applications of Rapid Assessment of Pathogenic Bacteria, so exciting to witness and contribute to.

Stewart, G.N., The changes produced by the growth of bacteria in the molecular concentration and electrical conductivity of culture media, Journal of Experimental Medicine, 1899, 4 (2): 235–243. https://doi.org/10.1084/jem.4.2.235 Stewart G.N. , The changes produced by the growth of bacteria in the molecular concentration and electrical conductivity of culture media , Journal of Experimental Medicine , 1899 , 4 ( 2 ): 235 243 . https://doi.org/10.1084/jem.4.2.235 Search in Google Scholar

David S., Polonschii C., Gheorghiu M. et al. Assessment of pathogenic bacteria using periodic actuation, Lab Chip., 2013, 13, 3192. https://doi.org/10.1039/c3lc50411e David S. Polonschii C. Gheorghiu M. Assessment of pathogenic bacteria using periodic actuation , Lab Chip. , 2013 , 13 , 3192 . https://doi.org/10.1039/c3lc50411e Search in Google Scholar

David, S., Munteanu, R.-E., Tițoiu, A.M. et al. Direct, Rapid Detection of Pathogens from Urine Samples, Materials, 2022, 15, 7640. https://doi.org/10.3390/ma15217640 David S. Munteanu R.-E. Tițoiu A.M. Direct, Rapid Detection of Pathogens from Urine Samples , Materials , 2022 , 15 , 7640 . https://doi.org/10.3390/ma15217640 Search in Google Scholar

Spencer, D.C., Paton, T.F., Mulroney, K.T. et al. A fast impedance-based antimicrobial susceptibility test, Nat Commun.,2020, 11, 5328. https://doi.org/10.1038/s41467-020-18902-x Spencer D.C. Paton T.F. Mulroney K.T. A fast impedance-based antimicrobial susceptibility test , Nat Commun. , 2020 , 11 , 5328 . https://doi.org/10.1038/s41467-020-18902-x Search in Google Scholar

Zhang, F., Wang, S., Yang, Y.et al. Imaging Single Bacterial Cells with Electro-optical Impedance Microscopy, ACS Sens., 2021,6(2), 348. https://doi.org/10.1021/acssensors.0c00751 Zhang F. Wang S. Yang Y. Imaging Single Bacterial Cells with Electro-optical Impedance Microscopy , ACS Sens. , 2021 , 6 ( 2 ), 348 . https://doi.org/10.1021/acssensors.0c00751 Search in Google Scholar

Polonschii, C., Gheorghiu, M., David, S. et al. High-resolution impedance mapping using electrically activated quantitative phase imaging, Light Sci Appl, 2021, 10, 20. https://doi.org/10.1038/s41377-020-00461-x Polonschii C. Gheorghiu M. David S. High-resolution impedance mapping using electrically activated quantitative phase imaging , Light Sci Appl , 2021 , 10 , 20 . https://doi.org/10.1038/s41377-020-00461-x Search in Google Scholar

Articles recommandés par Trend MD