Comparative testing of two alternating current methods for determining wood moisture content in kiln conditions
, , et
01 déc. 2021
À propos de cet article
Catégorie d'article: Research paper
Publié en ligne: 01 déc. 2021
Pages: 72 - 87
Reçu: 23 août 2021
Accepté: 04 oct. 2021
DOI: https://doi.org/10.2478/fsmu-2021-0005
Mots clés
© 2021 by the authors., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

Figure 7.

Figure 8.

Figure 9.

Figure 10.

Figure 11.

The main physical reliability characteristics of the dielectric capacitance method (DECM) in kiln climate and the corresponding capacitance meter (CAM) response_
Effect, parameter, figure no. | Effect range | CAM response |
Condensation of water vapor on MEC plates, |
Cparasite = 340 to 845 pF |
CAM reading recorded ca. 5× and moderately increasing |
Leakage of MEC insulators, |
Cparasite = 163 to 681 pF |
Floating of CAM reading |
Triboelectric charges on MEC plates, |
Ustatic = -10.5 to 4.29 V | Floating of CAM reading, CAM spoilage risk |
Useful MEC capacitance, |
Cuseful = 121 to 205 pF |
CAM reading stable and reliable |
Modelling results of the dielectric capacitance method (DECM) and electric impedance spectrometry (EIS) method_ In regression models, the independent x-variable is the actual MC (%), and the dependent y-variable is the predicted MC (%)_ The predicted single measurement tolerance bands on the 95% confidence level, yupper and ylower, are calculated using formulas 2, 3, 4 and 5_ The SE is calculated according to formula 6_ The tolerance interval (TI) is calculated using the formula TI = yupper - ylower_ N is the number of measurements repeated under the same test conditions and k is the number of measurements averaged per series of measurements (i_e_, the averaging period)_ For models with a series of measurements (k), the identification type shall be “multiple”_
Method type, Fig. no. | Equations for predicting single measurement tolerance bands and TI | R2 | p-value and tests |
SE | |
---|---|---|---|---|---|
DECM (above FSP), |
0.97 | <0.01 |
4.88 | ||
DECM (below FSP), |
0.99 | <0.01 |
0.61 | ||
DECM (above FSP) (multiple), |
0.99 | <0.01 |
0.46 | ||
EIS (above FSP), |
0.87 | <0.01 |
5.01 | ||
EIS (above FSP) (multiple), |
0.99 | <0.01 |
0.867 |