Loop-Mediated Isothermal Amplification as a Simple Molecular Method for the Detection of Derzsy’s Disease Virus
, et
15 mars 2013
À propos de cet article
Publié en ligne: 15 mars 2013
Pages: 19 - 23
DOI: https://doi.org/10.2478/bvip-2013-0004
Mots clés
© 2013
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
The objective of the study was to develop a simple and rapid molecular method for the detection of GPV. Twenty seven goose parvovirus (GPV) isolates collected from geese flocks in Poland were examined. Three pairs of specific primers: two outer primers (F3 and B3), two inner primers (FIP and BIP), and two loop primers (FL and BL) were used to accelerate the reaction. The optimum temperature and time of the reaction were 60°C and 30 min. The sensitivity of the method was 10-times higher than PCR. The method proved to be a sensitive, rapid, and specific assay for detecting GPV.