Geophysical Assessment of Groundwater Vulnerability to Diesel Contamination at a Telecommunication Mast in Adebayo Area, Ado-Ekiti, Southwestern Nigeria
Publié en ligne: 01 juil. 2021
Pages: 1 - 8
Reçu: 12 déc. 2020
Accepté: 01 mars 2021
DOI: https://doi.org/10.2478/ast-2021-0001
Mots clés
© 2021 Olaseeni Olayiwola et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
An appraisal of the groundwater vulnerability to contamination risk at Adebayo in Ado-Ekiti, Southwestern Nigeria, was carried out using the electrical resistivity method of geophysical prospecting. Two traverses of length 100 m each were established for both vertical electrical sounding (VES) and dipole-dipole. Six (6) Vertical Electrical Sounding (VES) and 2-D dipole-dipole profiling techniques of the electrical resistivity method were adopted for the geophysical investigation. The results show variations in resistivity values, depicting four to five geologic layers: the topsoil, laterite, weathered layer, fractured, and the fresh basement. It was observed from the correlation of the geoelectric section and 2-D resistivity image along traverse 1 (TR1) that the groundwater in the study area flows towards the southwestern part, and the fractured basement serves as a migration pathway to the diesel oil in the same direction as groundwater flow. The fractured basement (Well 2) with no lateritic cover has higher resistivity values compare to the fracture zone that was found directly under the mast which was overlain by the laterite. Comparing the resistivity values of Well 1 and 2, Well 2 that was drilled into the fractured basement has more traces of the contaminant than Well 1.