It may be said that this was the first time in World War II that data sampling was used to control rotating radar systems (Zarchan, 2019).
One of the most serious studies and participations in the study of sampling methods, known as frequency analysis, is mentioned in reference (Jacquot, 2019). This article describes the use of this technique in developing a control system. In (Kim, 2020) published a book describing and explaining both methods, especially the vector decomposition method. Following this research, Friedland applied the technique of frequency analysis to periodic control structures, and this theory was developed by Salt et al. (2020). To systems with multiple feedback loops and different sampling rates. Since then, researchers have discovered the potential of multicast systems and beyond a single technique to analyze single-rate systems. At that time, the keyhole analysis method was used in a completely logical and effective way to design and expand such systems. In the same reference, Kranc came up with the idea of replacing multi-rate control instead of single-rate control in systems with variable dynamics (Li et al., 2002). Whitbeck presented a vectoring method for key analysis and generalized it to flight control issues (Harvey and Pope, 1982; Salt et al., 2020).
Methods on the stability of state-of-the-art space in the field of continuous time with the subject of analysis and design of multi-rate systems to achieve the stability of these systems were presented by (Dick, 2018) by publishing their article. This paper made a significant contribution to demonstrating the power of state space methods in describing a large number of single-rate sampling control systems with time changes.
After that, researchers at TASC developed a new approach to multi-rate control design based on optimal control and estimation formulation. This study included a mathematical formulation of the problem of designing, improving and upgrading design techniques, computational methods and the application of these methods in flight control examples (Perez-Montenegro et al., 2019; Ma et al., 2020).
Naturally, the guidance law system, autopilot, and search seeker of a guided missile have different sensors at different operating rates. Certainly, selecting these components in such a way that they all work at a single rate equal to the operating rate of the system will limit the choice and affect the accuracy and ultimately the performance of the system. In this paper, after introducing the operation of multi-rate systems, a guided missile, including the guidance law, automated pilot and searcher with different and different rates of input and output is simulated and its performance is examined in several different scenarios of target movement and optimal performance.
Consider a system with inputs and outputs at different rates according to Figure 1A.
For such system, it is assumed that the input and output are sampled in rate of
In these relationships,
Figure 1:
Multipurpose system: (A) Simple view of a multi-rate system, (B) Decomposed form of switching, (C) Vectored decomposed form.

If
The system descriptive equations of Figure 1C are written as equation (3):
The multi-rate operators
The term
which can be expressed as (6)
which
Re-expression of equation (6) in the form of vector, will include all the behavior of the internal samples of the multi-rate system, but they are not a desirable and appropriate form for use in classical analyzes. For example, it may not lead to an equation with analytical properties. Although we know that the Kranc method of operation ensures that the transmission of all routes is affected by multi-rate sampling by rushing and delaying blocks (Kellermann, 1988; van der Zee and Han, 2001; Han and Ding, 2010).
Therefore, by replacing the multi-rate system with different input and output rates with the equivalent one; the system can be expressed with the standard signal flow graph and simplified and analyzed with diagram block reduction techniques.
For this purpose, the general equations for a multi-rate system (integer and logical rates) and with multiple inputs–multiple outputs will be explained.
For a general model of multi-rate, multi-input, multi-output system with
By defining
Matrix
Also, matrix
In this case, the
In this regard, the
Index
Index
In relation (12),
The general output equation of a multi-rate system is similarly defined as (13)
which is defined in relation
We also define
The
All the equations for transferring a multi-rate system are calculated by considering how the
It must be noted that for some internal sampling moments, there will be no any change in system input and output. At this point, multi-rate system matrices include phrases that represent the system’s natural response to the last input (output). Therefore, it can be said that these matrices include many terms that do not express any characteristics of input and output.
It is worth noting that the relationship (8) is non-minimal obviously, because it describes the multi-rate system with
In the following, the minimal state space model for a multi-rate system with one input and one output will be discussed, noting that the input sampling rate includes several different rates and the output rate is constant.
To get the equations of a multi-input single output (MISO) system, we must first answer the question of how does
For this system, the input signal is sampled at
In which,
Considering the
If
In equation (19),
In (20),
It is worth noting that considering some conditions for
Equation (19) can also be rewritten in the following matrix form
In relation (21),
In relation (23),
Since the state and output vectors are defined only in the main sampling intervals, the output equation is defined as relation (24).
To achieve state equations for a system with multiple inputs at different rates, we can rewrite equation (21) as (25).
Which in relation (25)
Multi-rate system matrices in equation (25), use control and state matrices of multi-input multi-output.
The vector
The relation (26) shows that the multi-rate control matrix is a block related to the maximum value of
A guided missile consists of three main parts (Farret et al., 2002): the seeker (Lee, 2019), autopilot (Lee and Tahk, 2019) and the guidance law (Sun et al., 2019) systems. In this simulation, it is assumed that the commands of the output lateral acceleration of these parts (finally the output of the auto-pilot) are sent to the canards at a constant rate of 120 ms. On the other hand, the output signal of seeker will be sampled at a rate of 40 ms and the final output will be sampled at a rate of 60 ms and sent to the guidance law subsystem. The output of the guidance law subsystem will also be sent to the autopilot at a rate of 30 ms. Block diagram of Figure 2 for the following reasons is an objective example of a multi-rate system:
Figure 2:
Block diagram of simulated multi-rate guided missile.

Existence of different input and output rates between different parts.
Existence of input signals with different rates for the base subsystem of guidance law and one output signal with a different rate of inputs.
In Figure 2, seeker, guidance law, and the autopilot are simulated according to the references. Also, after applying the explained multi-rate method and obtaining inputs and outputs, a scenario for target maneuvering and guided missile testing is considered, and after expressing the scenario, simulation results will be shown.
In the simulation results, Figure 3 shows the path of the missile and the target on the
Figure 3:
The path of the missile and the target on the

Figure 4:
Missile–target engagement in

Figure 5:
Missile–target engagement in

Figure 6:
Missile–target engagement in

Acceleration commands for
Figure 7:
Acceleration command in

Figure 8:
Acceleration command in

Figure 9:
Acceleration command in

This scenario is the linear movement of the target at constant altitude and speed without acceleration. The values of acceleration, velocity and target position in the three directions of
The simulation results are shown in Figures 3–9:
The lateral acceleration commands from the autopilot in
As we can see, the simulation results show well that despite the use of different sampling rates in the subsystems, the missile guidance and control during the path to the target is done in the best possible optimal way with a smooth motion and it has not been affected by the existence of multi rate operation of the missile.
To validate the simulation results, it is enough to pay attention to the smooth and uniform movement of the missile along the flight path towards the target which shows the optimal performance of the proposed method. The results clearly show that along the flight path, the missile moved quite smoothly and no data was lost due to the difference in sampling rates in the system. Also, because the target maneuver is designed by the authors themselves in such a way that the maneuver is complete and similar to reality and on the other hand, the proposed method has been proposed and invented by the authors themselves and there is no similar case with these specifications for comparison and as it was stated, based on the smooth movement and no loss of data, despite the various sampling rates in the system, the optimality and acceptable performance of the proposed method can be concluded.
In process of digital system designing, choosing system performance rate, selecting of sensors and the components of processor are very important and the designer will be at a crossroads whether to act based on available performance rate or desired accuracy.
The results obtained in this study shows that by determining the rate of output and input of multi-rate systems, despite the existence of different rates at the input of different subsystems, without interfering with the performance of the whole system and losing data, the system output will be determined in one single rate. Simulation results also shows good performance and smooth movement without any data loss.
Figure 1:

Figure 2:

Figure 3:

Figure 4:

Figure 5:

Figure 6:

Figure 7:

Figure 8:

Figure 9: