À propos de cet article

Citez

Chetan Sharma, Sachin Kumar, Anshul Bhargava, Shubhajit Roy Chowdhury. “Field programmable gate array based embedded system for non-invasive estimation of hemoglobin in blood using photoplethysmography.” International Journal on Smart Sensing and Intelligent Systems, vol. 6, no. 3, pp. 1267- 1282, 2013. Search in Google Scholar

Lieschnegg, M., M. Zacherl, B. Lechner, C. Weger, and A. Fuchs. “Non-invasive characterization of total hip arthroplasty by means of passive acceleration measurement.” International Journal on Smart Sensing and Intelligent Systems, vol. 3, no. 1, pp. 75-87, 2010.10.21307/ijssis-2017-380 Search in Google Scholar

Gavin, J.R. “The Importance of Monitoring Blood Glucose”. In US Endocrine Disease; Touch Briefings: Atlanta, GA, USA, pp. 1–3, 2007. Search in Google Scholar

C. Turner, C. Walton, S. Hoashi, and M. Evans, “Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps,” Journal of breath research, vol. 3, no. 4, pp. 1-9, 2009.10.1088/1752-7155/3/4/04600421386197 Search in Google Scholar

Md. Mahbubur Rahman, A. J. Saleh Ahammad, Joon-Hyung Jin, Sang Jung Ahn and Jae-Joon Lee, “A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides:” Sensors, vol. 10, pp. 4855-4886, 2010. Search in Google Scholar

Tong Wang, Yanan Yu, Huifeng Tian and Jingbo Hu, “A Novel Non-Enzymatic Glucose Sensor Based on Cobalt Nanoparticles Implantation-Modified Indium Tin Oxide Electrode,” Electroanalysis, vol. 26, pp. 2693–2700, 2014. Search in Google Scholar

Saei, A. A., Dolatabadi, J. E. N., Najafi-Marandi, P., Abhari, A., De la Guardia, M.: “Electrochemical biosensors for glucose based on metal nanoparticles”. TrAC Trends in Analytical Chemistry, vol. 42, pp. 216–227, 2013.10.1016/j.trac.2012.09.011 Search in Google Scholar

Dongyuan Zhai, Borui Liu, Yi Shi, Lijia Pan, Yaqun Wang, Wenbo Li, Rong Zhang, and Guihua Yu, “Highly Sensitive Glucose Sensor Based on Pt Nanoparticle/Polyaniline Hydrogel Heterostructures,” ACS Nano, vol. 7, pp. 3540–3546, 2013. Search in Google Scholar

S. Updike, G. Hicks, “The enzyme electrode”, nature publishing group, vol. 214, pp. 986– 988, 1967.10.1038/214986a06055414 Search in Google Scholar

Luaibi, Ahmed Y., Ahmed J. Al-Ghusain, Asif Rahman, Mohammad H. Al-Sayah, and Hasan Al-Nashash. “Noninvasive blood glucose level measurement using nuclear magnetic resonance.” Proceeding of 8th IEEE GCC Conference and Exhibition (GCCCE), Muscat, pp. 1-4, 2015.10.1109/IEEEGCC.2015.7060028 Search in Google Scholar

Ramasahayam, Swathi, Sri Haindavi Koppuravuri, Lavanya Arora, and Shubhajit Roy Chowdhury. “Noninvasive Blood Glucose Sensing Using Near Infra-Red Spectroscopy and Artificial Neural Networks Based on Inverse Delayed Function Model of Neuron.” Journal of medical systems, vol. 39, no. 1, pp. 1-15, 2015.10.1007/s10916-014-0166-225503416 Search in Google Scholar

U. MÜller, B. Mertes, C. Fischbacher, K. Jageman, and K. Danzer, “Non-invasive blood glucose monitoring by means of near infrared spectroscopy: methods for improving the reliability of the calibration models.” The International journal of artificial organs, vol. 20, no. 5, pp. 285– 290, 1997.10.1177/039139889702000509 Search in Google Scholar

G. Dongmin, D. Zhang, L. Zhanga, L. Guangming “Non-invasive blood glucose monitoring for diabetics by means of breath signal analysis”, Sensors and Actuators B: Chemical, volume 173, pp. 106–113, October 2012.10.1016/j.snb.2012.06.025 Search in Google Scholar

S. Vashist, “Non-invasive glucose monitoring technology in diabetes management: A review”, Analytica Chimica Acta, vol. 750, pp. 16–27, 2012.10.1016/j.aca.2012.03.04323062426 Search in Google Scholar

Mohammad Goodarzi, Sandeep Sharma, Herman Ramon, Wouter Saeys, “Multivariate calibration of NIR spectroscopic sensors for continuous glucose monitoring,” TrAC Trends in Analytical Chemistry, vol. 67, pp. 147–158, 2015.10.1016/j.trac.2014.12.005 Search in Google Scholar

Marco Righettoni, Anton Amann and Sotiris E. Pratsinis, “Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors,” Materials Today, vol. 18, pp. 163-171, 2015.10.1016/j.mattod.2014.08.017 Search in Google Scholar

Paweł Mochalski, Karl Unterkofler, Gerald Teschl, Anton Amann, “Potential of volatile organic compounds as markers of entrapped humans for use in urban search-and-rescue operations,” TrAC Trends in Analytical Chemistry, vol. 68, pp. 88–106, 2015.10.1016/j.trac.2015.02.013 Search in Google Scholar

Q. Zhang, P. Wang, J. Li, and X. Gao, “Diagnosis of diabetes by image detection of breath using gas-sensitive laps,” Biosensors and Bioelectronics, vol. 15, no. 5, pp. 249–256, 2000.10.1016/S0956-5663(00)00064-6 Search in Google Scholar

C. Deng, J. Zhang, X. Yu, W. Zhang, and X. Zhang, “Determination of acetone in human breath by gas chromatography–mass spectrometry and solid-phase microextraction with on-fiber derivatization,” Journal of Chromatography B, vol. 810, no. 2, pp. 269–275, 2004.10.1016/S1570-0232(04)00657-9 Search in Google Scholar

S. Chakraborty, I. Ray, A. Sen, and D. Banerjee, “Detection of biomarker in breath: A step towards noninvasive diabetes monitoring,” Current Science, vol. 94, no. 2, pp. 237–242, 2008. Search in Google Scholar

Nasution, Tulus Ikhsan, Irwana Nainggolan, Sabar Derita Hutagalung, Khairel Rafezi Ahmad, and Zainal Arifin Ahmad. “The sensing mechanism and detection of low concentration acetone using chitosan-based sensors.” Sensors and Actuators B: Chemical, vol. 177, pp. 522528, 2013. Search in Google Scholar

Hill, Darryl, and Russell Binions. “Breath analysis for medical diagnosis.” International Journal on Smart Sensing and Intelligent Systems, vol. 5, no. 2, pp. 401-440, 2012.10.21307/ijssis-2017-488 Search in Google Scholar

Elosua, Cesar, Ignacio R. Matias, Candido Bariain, and Francisco J. Arregui. “Detection of volatile organic compounds based on optical fibre using nanostructured films.” International Journal on Smart Sensing and Intelligent Systems, vol. 1, no. 1, pp. 123-136, 2008.10.21307/ijssis-2017-282 Search in Google Scholar

Yu-Feng Sun, Shao-Bo Liu, Fan-Li Meng, Jin-Yun Liu, Zhen Jin, Ling-Tao Kong and Jin- Huai Liu, “Metal Oxide Nanostructures and Their Gas Sensing Properties: A Review,” Sensors, vol. 12, pp. 2610-2631, 2012. Search in Google Scholar

V.K. Khanna, “Nanoparticle-based Sensors,” Defence Science Journal, vol. 58, pp. 608-616, 2008.10.14429/dsj.58.1683 Search in Google Scholar

C.-C. Wang, Y.-C. Weng, and T.-C. Chou, “Acetone sensor using lead foil as working electrode,” Sensors and Actuators B: Chemical, vol. 122, no. 2, pp. 591–595, 2007.10.1016/j.snb.2006.07.003 Search in Google Scholar

J. Li, Y. Lu, Q. Ye, M. Cinke, J. Han, and M. Meyyappan, “Carbon nanotube sensors for gas and organic vapor detection,” Nano Letters, vol. 3, no. 7, pp. 929–933, 2003.10.1021/nl034220x Search in Google Scholar

D. Zohir and B. Hakim, “Enhancement of the neural network modeling accuracy using a submodeling decomposition-based technique, application in gas sensor,” Neural Computing and Applications, vol. 21, no. 8, pp. 1981–1986, 2012. Search in Google Scholar

Dmitriev, S. “Nanosensors engineering: I. structurally modulated sno2 nanowires.” International Journal on Smart Sensing and Intelligent Systems, vol. 3, no. 4, pp. 643- 654, 2010.10.21307/ijssis-2017-413 Search in Google Scholar

Zvyagin, A. A., A. V. Shaposhnik, S. V. Ryabtsev, D. A. Shaposhnik, A. A. Vasil’ev, and I. N. Nazarenko. “Determination of acetone and ethanol vapors using semiconductor sensors.” Journal of Analytical Chemistry, vol. 65, no. 1, pp. 94-98, 2010.10.1134/S1061934810010181 Search in Google Scholar

N. K. Suryadevara, S. C. Mukhopadhyay and L. Barrack, Towards a Smart Non-Invasive Fluid Loss Measurement System, Journal of Medical Systems, Springer (NON-INVASIVE DIAGNOSTIC SYSTEMS), February 2015, 39:38, 10 pages, DOI 10.1007/s10916-015-0206-6.10.1007/s10916-015-0206-625686913 Search in Google Scholar

A. Reungchaiwat, T. Wongchanapiboon, S. Liawruangrath, and S. Phanichphant, “Homemade detection device for a mixture of ethanol and acetone,” Sensors, vol. 7, no. 2, pp. 202–213, 2007.10.3390/s7020202 Search in Google Scholar

Yadav, Lokendra. “Noninavsive biosensor for diabetes monitoring.” Asian Journal of Pharmaceutical and Clinical Research, vol. 7, no. 3, pp. 206-211, 2014.Search in Google Scholar

eISSN:
1178-5608
Langue:
Anglais
Périodicité:
Volume Open
Sujets de la revue:
Engineering, Introductions and Overviews, other