Non-contrast ultrasound assessment of blood flow in clinical practice
Catégorie d'article: Review paper
Publié en ligne: 30 nov. 2024
Pages: 1 - 9
Reçu: 15 janv. 2024
Accepté: 26 mars 2024
DOI: https://doi.org/10.15557/jou.2024.0029
Mots clés
© 2024 Emmanuel Abiola Babington et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Fig. 1.

Fig. 2.

Fig. 3.

Fig. 4.

Fig. 5.

Summary of various non-contrast ultrasound flow modes_ Microvascular imaging (McVI) nomenclatures used by different ultrasound manufacturers (listed alphabetically)
Company | Canon Medical Systems | General Electric Healthcare | Hitachi Medical Systems | Philips Healthcare | Samsung Medison | Siemens Healthineers |
---|---|---|---|---|---|---|
Superb Microvascular Imaging | MicroVascular Imaging | eFlow | MicroFlow Imaging | MicroVascular Flow | Slow Flow | |
SMI | MVI | – | MFI | MV Flow | - |
Summary of various non-contrast ultrasound flow modes
Flow mode | CDI | PDI | ADF | McVI | B-flow |
---|---|---|---|---|---|
Working principle | Doppler | Doppler | Doppler | Doppler | Non-Doppler |
Generation | 1st Gen. | 2nd Gen. | 3rd Gen. | 3rd Gen. | 3rd Gen. |
Adjustable Doppler box Provides flow directionality information Available on all ultrasound machines and probes Better penetration than MVI and B-flow |
More sensitive than CDI Adjustable Doppler box Available on all ultrasound machines and probes Better penetration than MVI and B-flow |
Suitable for examining the fetal placental vessels and fetal heart chambers Shows flow directionality |
The most sensitive (non-contrast) flow mode to microvascularity Can prevent the need for other invasive or radiation examinations |
Not angle-dependent Sensitive to slow flows Can visualize tiny vessels Provides flow information of the entire ultrasound screen; no Doppler box is required |
|
Filters out microvascularity Angle dependent Prone to aliasing |
Filters out microvascularity Focuses more on flow intensity over velocity |
Least sensitive to microvascularity Provided by only one manufacturer |
Doppler box is limited in size. Only available on high-end ultrasound machines Not available on all ultrasound probes Less sensitive than CDI and PDI in deeper organs Focuses more on flow intensity over velocity |
No information on flow directionality Provided by only one manufacturer It is not currently available on all ultrasound probes Less sensitive than CDI and PDI in deeper organs Focuses more on flow intensity over velocity |