The Influence of Measurement Methodology on the Accuracy of Electrical Waveform Distortion Analysis
et
04 avr. 2018
À propos de cet article
Publié en ligne: 04 avr. 2018
Pages: 72 - 78
Reçu: 30 sept. 2017
Accepté: 20 mars 2018
DOI: https://doi.org/10.1515/msr-2018-0011
Mots clés
© 2018 Jacek Bartman et al., published by De Gruyter Open
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
The present paper covers a review of documents that specify measurement methods of voltage waveform distortion. It also presents measurement stages of waveform components that are uncommon in the classic fundamentals of electrotechnics and signal theory, including the creation process of groups and subgroups of harmonics and interharmonics. Moreover, the paper discusses selected distortion factors of periodic waveforms and presents analyses that compare the values of these distortion indices. The measurements were carried out in the cycle per cycle mode and the measurement methodology that was used complies with the IEC 61000-4-7 norm. The studies showed significant discrepancies between the values of analyzed parameters.