À propos de cet article
Publié en ligne: 07 oct. 2015
Pages: 127 - 140
Reçu: 22 sept. 2014
DOI: https://doi.org/10.1515/heem-2015-0008
Mots clés
© by Tomasz Kolerski
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
A poorly designed culvert inlet structure causes scouring, which can lead to the collapse of the culvert and significant damage to the neighboring land. A set of laboratory tests was evaluated to examine velocity distribution at the culvert inlet. A three-dimensional acoustic Doppler velocimeter was used to measure instantaneous flow velocity upstream of the culvert. The analysis of mean velocities, turbulence strength, and Reynolds stresses was performed to understand the flow structure near the culvert entrance.