Iniciar sesión
Registrarse
Restablecer contraseña
Publicar y Distribuir
Soluciones de Publicación
Soluciones de Distribución
Temas
Arquitectura y diseño
Artes
Ciencias Sociales
Ciencias de la Información y Bibliotecas, Estudios del Libro
Ciencias de la vida
Ciencias de los materiales
Deporte y tiempo libre
Estudios clásicos y del Cercano Oriente antiguo
Estudios culturales
Estudios judíos
Farmacia
Filosofía
Física
Geociencias
Historia
Informática
Ingeniería
Interés general
Ley
Lingüística y semiótica
Literatura
Matemáticas
Medicina
Música
Negocios y Economía
Química
Química industrial
Teología y religión
Publicaciones
Revistas
Libros
Actas
Editoriales
Blog
Contacto
Buscar
EUR
USD
GBP
Español
English
Deutsch
Polski
Español
Français
Italiano
Carrito
Home
Revistas
Nukleonika
Volumen 67 (2022): Edición 2 (June 2022)
Acceso abierto
Utilization of an energy-resolving detection system for mammography applications: A preliminary study
Eslam M. Taha
Eslam M. Taha
,
Ezzat A. Elmoujarkach
Ezzat A. Elmoujarkach
,
Ahmed Balamesh
Ahmed Balamesh
,
Samir A. Alzaidi
Samir A. Alzaidi
y
Abdulsalam M. Alhawsawi
Abdulsalam M. Alhawsawi
| 11 jun 2022
Nukleonika
Volumen 67 (2022): Edición 2 (June 2022)
Acerca de este artículo
Artículo anterior
Artículo siguiente
Resumen
Artículo
Figuras y tablas
Referencias
Autores
Artículos en este número
Vista previa
PDF
Cite
Compartir
Article Category:
Original Paper
Publicado en línea:
11 jun 2022
Páginas:
35 - 40
Recibido:
27 sept 2021
Aceptado:
03 mar 2022
DOI:
https://doi.org/10.2478/nuka-2022-0003
Palabras clave
Energy-resolving detection systems
,
Gamma-ray imaging
,
GATE simulation toolkit
,
Mammography
© 2022 Eslam M. Taha et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Fig. 1
Experimental setup from left showing the Am-241 in the blue containment shield, the ACR phantom placed in the mechanical arm surrounded with lead blocks to stabilize the arm movement, and finally is the NaI detector with a lead sleeve to shield it from the scattered radiation. 1 – ACR phantom, 2 – NaI crystal, 3 – Am-241 source.
Fig. 2
The simulation setup where the green beam represents the γ-rays. The yellow squares are the pre- and post-lead collimators. The red box is the detector. The gray box is the ACR phantom that shows in the top the five masses representing the tumours with diameters of 12, 9, 7, 5, and 4 mm.
Fig. 3
Reconstructed 26.3 keV image (left) and 59.5 keV (right).
Fig. 4
The energy spectrum of a single tumour pixel. The 26.3 keV peak is located at channel 12, while the 59.5 keV peak is located at channel 24.
Fig. 5
An image of the ACR mammographic phantom taken with Am-241 photons and a computed radiography detector.
Fig. 6
Images produced with 59.5 keV photons (left) and 26.3 keV photons (right) using 1 mm openings.
Fig. 7
Images produced with 59.5 keV photons (left) and 26.4 keV photons (right) using a 0.5 mm openings.
Fig. 8
A magnified image of the largest microcalcification cluster. Only four out of six microcalcifications are detected.