Steel-concrete composite bridges are commonly designed with full composite action between the steel girders and the concrete deck to enhance structural efficiency and durability. This composite action is achieved through shear connectors, which transfer shear forces and ensure that both materials act as a single unit. While full composite action is preferred, partial composite action may be sufficient in certain cases, depending on interlocking effects between steel and concrete. One strategy to improve the performance of composite bridges is the implementation of horizontal trusses between the lower flanges of the steel girders, which enhance load distribution and lateral stability.

Although previous research has investigated the effects of horizontal trusses on global load distribution, their influence on shear force distribution, particularly at shear connectors, remains largely unexplored. Studies on monorail track beams indicate that transverse shear forces significantly affect shear connectors, reducing their capacity and altering failure mechanisms. A similar effect may occur in composite bridges with twin girders and horizontal trusses.

This paper presents a case study of a single-span steel-concrete bridge in Sweden, examining the impact of a torsional rigid structure with a semi-closed cross-section on local shear flow distribution. The study also investigates how shear connector rigidity affects force distribution along the steel-concrete interface.

Idioma:
Inglés
Calendario de la edición:
2 veces al año
Temas de la revista:
Ciencia de los materiales, Procesamiento de materiales