Research on closed-loop utilization of engineering waste mud in engineering sites
y
30 ene 2024
Acerca de este artículo
Publicado en línea: 30 ene 2024
Páginas: 99 - 110
Recibido: 01 nov 2023
Aceptado: 09 dic 2023
DOI: https://doi.org/10.2478/msp-2023-0035
Palabras clave
© 2023 Jinsheng Zhan et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Fig. 1.

Fig. 2.

Fig. 3.

Fig. 4.

Fig. 5.

Fig. 6.

Fig. 7.

Fig. 8.

Fig. 9.

Fig. 10.

Fig. 11.

Mix-ratio of fluidized solidified soil
Samples | Soil type | Soil (kg) | Cement (kg) | Water (kg) | Water type | Flocculant as a percentage of cement (%) |
---|---|---|---|---|---|---|
1 | No flocculant | 10 | 0.5 | 3 | Tap-water | 0 |
2 | No flocculant | 10 | 0.5 | 3 | Supernatant with PAC+APAM | <0.1% |
3 | Add PAC | 10 | 0.5 | 3 | Supernatant with PAC | ~8.0% |
4 | Add APAM | 10 | 0.5 | 3 | Supernatant with APAM | ~2.4% |
5 | Add PAC+APAM | 10 | 0.5 | 3 | Supernatant with PAC+APAM | ~10.4% |
Samples with different flocculants added
Samples | 1.0% PAC | 0.3% APAM |
---|---|---|
Original mud | Water 10ml | |
A | 10ml | / |
B | / | 10ml |
C | First add 10ml of PAC, stir for 10s, and then add 10ml of APAM | |
D | 10mlPAC+10ml APAM | |
E | First add 10ml of APAM, stir for 10s, and then add 10ml of PAC |