Combs MR, Bredehoeft SJ. Selecting an acceptable and safe antibody detection test can present a dilemma. Immuno-hematology 2001;17:86–9.CombsMRBredehoeftSJ.Selecting an acceptable and safe antibody detection test can present a dilemma. Immuno-hematology2001;17:86–9.Search in Google Scholar
Hill BC, Hanna CA, Adamski J, Pham HP, Marques MB, Williams LA 3rd. Ficin-treated red cells help identify clinically significant alloantibodies masked as reactions of undetermined specificity in gel microtubes. Lab Med 2017;48:24–8. https://doi.org/10.1093/labmed/lmw062HillBCHannaCAAdamskiJPhamHPMarquesMBWilliamsLA3rd.Ficin-treated red cells help identify clinically significant alloantibodies masked as reactions of undetermined specificity in gel microtubes. Lab Med2017;48:24–8. https://doi.org/10.1093/labmed/lmw062Search in Google Scholar
Zeiler T, Thiele S, Kretschmer V. Solid phase technique versus gel centrifugation for detection of erythrocyte antibodies: a prospective study comparison the 2 antibody detection tests. Beitrage zur Infusionstherapie und Transfusionsmedizin 1996;33:17–21.ZeilerTThieleSKretschmerV.Solid phase technique versus gel centrifugation for detection of erythrocyte antibodies: a prospective study comparison the 2 antibody detection tests. Beitrage zur Infusionstherapie und Transfusionsmedizin1996;33:17–21.Search in Google Scholar
Shin JW. Unexpected red cell antibody detection by conditional combination of LISS/Coombs and NaCl/enzyme gel tests at a tertiary hospital in Korea: a 5-year study. Blood Res 2013;48:217–21. https://doi:10.5045/br.2013.48.3.217ShinJW.Unexpected red cell antibody detection by conditional combination of LISS/Coombs and NaCl/enzyme gel tests at a tertiary hospital in Korea: a 5-year study. Blood Res2013;48:217–21. https://doi:10.5045/br.2013.48.3.217Search in Google Scholar
Enko D, Habres C, Wallner F, Mayr B, Halwachs-Baumann G. Frequencies and specificities of ‘‘enzyme-only’’ detected erythrocyte alloantibodies in patients hospitalized in Austria: is an enzyme test required for routine red blood cell antibody screening? J Blood Transfus 2014;532919. https://doi.org/10.1155/2014/532919EnkoDHabresCWallnerFMayrBHalwachs-BaumannG.Frequencies and specificities of ‘‘enzyme-only’’ detected erythrocyte alloantibodies in patients hospitalized in Austria: is an enzyme test required for routine red blood cell antibody screening?J Blood Transfus2014;532919. https://doi.org/10.1155/2014/532919Search in Google Scholar
Yamane K, Yagihashi A, Sasaki M, Kuwashima K, Mono A, Watanabe N. A delayed hemolytic transfusion reaction (DHTR) with multiple alloantibodies (Anti-E, Jka, Dia, Fyb, and S) induced by E-antigen-negative, crossmatch-compatible blood. Immunopharmacology and Immunotoxicology 1998;20:531–9. https://doi:10.3109/08923979809031514YamaneKYagihashiASasakiMKuwashimaKMonoAWatanabeN.A delayed hemolytic transfusion reaction (DHTR) with multiple alloantibodies (Anti-E, Jka, Dia, Fyb, and S) induced by E-antigen-negative, crossmatch-compatible blood. Immunopharmacology and Immunotoxicology1998;20:531–9. https://doi:10.3109/08923979809031514Search in Google Scholar
Clark D, Greiss MA, Urbaniak SJ. A prospective study of routine antenatal enzyme antibody screening demonstrated lack of clinical value in predicting haemolytic disease of the newborn. Br J Haematol 1999;106:824–6.ClarkDGreissMAUrbaniakSJ.A prospective study of routine antenatal enzyme antibody screening demonstrated lack of clinical value in predicting haemolytic disease of the newborn. Br J Haematol1999;106:824–6.Search in Google Scholar
Weisbach V, Kohnhäuser T, Zimmermann R, et al. Comparison of the performance of microtube column systems and solidphase systems and the tube low-ionic-strength solution additive indirect antiglobulin test in the detection of red cell alloantibodies. Transfus Med 2006;16:276–84.WeisbachVKohnhäuserTZimmermannR, Comparison of the performance of microtube column systems and solidphase systems and the tube low-ionic-strength solution additive indirect antiglobulin test in the detection of red cell alloantibodies. Transfus Med2006;16:276–84.Search in Google Scholar
Schrem A, Flegel WA. Comparison of solid-phase antibody screening tests with pooled red cells in blood donors. Vox Sang 1996;71:37–42. https://doi.org/10.1046/j.1423-0410.1996.7110037.xSchremAFlegelWA.Comparison of solid-phase antibody screening tests with pooled red cells in blood donors. Vox Sang1996;71:37–42. https://doi.org/10.1046/j.1423-0410.1996.7110037.xSearch in Google Scholar
Conne J, Schneider P, Tissot JD. Role of enzyme-treated cells in RBC antibody screening using the gel test: a study of anti-RH1, -RH2, and -RH3 antibodies. J Clin Labor Anal 2007;21:61–6. https://doi.org/10.1002/jcla.20120ConneJSchneiderPTissotJD.Role of enzyme-treated cells in RBC antibody screening using the gel test: a study of anti-RH1, -RH2, and -RH3 antibodies. J Clin Labor Anal2007;21:61–6. https://doi.org/10.1002/jcla.20120Search in Google Scholar
Kay B, Poisson JL, Tuma CW, Shulman IA. Anti-Jka that are detected by solid-phase red blood cell adherence but missed by gel testing can cause hemolytic transfusion reactions. Transfusion 2016;56:2973–9.KayBPoissonJLTumaCWShulmanIA.Anti-Jka that are detected by solid-phase red blood cell adherence but missed by gel testing can cause hemolytic transfusion reactions. Transfusion2016;56:2973–9.Search in Google Scholar
Issitt PD, Combs MR, Bredehoeft SJ, et al. Lack of clinical significance of “enzyme-only” red cell alloantibodies. Trans-fusion 1993;33:284–93. https://doi:10.1046/j.1537-2995.1993. 33493242634.x. PMID: 8480348IssittPDCombsMRBredehoeftSJ, Lack of clinical significance of “enzyme-only” red cell alloantibodies. Trans-fusion1993;33:284–93. https://doi:10.1046/j.1537-2995.1993.33493242634.x. PMID: 8480348Search in Google Scholar