Comparison of Carotid Artery Dose in Early-Stage Glottic Cancer Treated with 3D-Conformal, Helical-IMRT and VMAT
Categoría del artículo: Research Article
Publicado en línea: 13 nov 2023
Páginas: 23 - 30
Recibido: 19 jun 2023
Aceptado: 07 oct 2023
DOI: https://doi.org/10.2478/fco-2023-0009
Palabras clave
© 2023 B Pires et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Background
The aim of this study was to compare the dosimetry of carotid arteries (CAs) using three radiation therapy (RT) techniques, three-dimensional conformal RT (3D-CRT), helical tomotherapy-intensity-modulated RT (HT-IMRT), and volumetric modulated arc therapy (VMAT), in patients with early-stage glottic cancer.
Patients and Methods
A retrospective analysis of 28 patients was performed, and the right and left CAs were delineated. Mean and maximum dose (Dmax) values were compared across the three treatment techniques.
Results
The results indicate that 3D-CRT plans had the highest mean and maximum doses to CAs, while VMAT plans had the lowest doses.
Conclusions
Our study demonstrates the feasibility of sparing CAs with newer RT modalities. Further clinical studies are needed to determine if these techniques can reduce carotid stenosis-related events.