Acceso abierto

Verification of the Computed Tomography Results of Aluminum Alloy Welded Joint


Cite

Computed tomography (CT) of aluminum welded joint specimen has been performed. On the tomographic cross sections some defects have been found. To verify them the metallography cross sections of welded has been done. It was found that selected defects are micro cracks.

eISSN:
2300-7591
Idioma:
Inglés
Calendario de la edición:
Volume Open
Temas de la revista:
Engineering, Introductions and Overviews, other