Application of Double Skin Façade (DSF) and Electrochromic Glass in Buildings in Tropical Climate


Cite

Figure 1

Building Simulation Floor Plan
Building Simulation Floor Plan

Figure 2

3D Simulation of Solar Circulation Line
3D Simulation of Solar Circulation Line

Figure 3

Front View of Simulation Building
Front View of Simulation Building

Figure 4

Double Skin Model on Simulated Building
Double Skin Model on Simulated Building

Figure 5

Glass Walls
Glass Walls

Figure 6

3D Simulation of Solar Rotation Line
3D Simulation of Solar Rotation Line

Figure 7

Locations of Measurement Spots
Locations of Measurement Spots

Figure 8

Measurement Results in the Instruction Room at 06.00 am & 5.00 pm
Measurement Results in the Instruction Room at 06.00 am & 5.00 pm

Figure 9

Electrochromic Glass Wall Material
Electrochromic Glass Wall Material

Figure 10

Results of Light Intensity Measurement
Results of Light Intensity Measurement

Wall area 114 m2
Glass area 45 m2
WWR 0.39
UW 1.06 W/m2K
TDeq 15 K
Uf 2.4 W/m2K
DT 3 K
SC 0.67
SF 97.9 W/m2

Results of Light Intensity Measurement

hour lowest intensity highest intensity
06.00 243.3 6,266.6
07.00 395.6 11,967.4
08.00 360.3 17,275.3
09.00 343.3 22,097.5
10.00 352.7 25,764.8
11.00 333.1 25,598.2
12.00 310.4 22,336.9
13.00 315.6 24,190.7
14.00 299.4 18,220.4
15.00 316.0 21,418.1
16.00 328.0 17,032.6
17.00 308.4 20,831.2

Results of Thermal Measurement in a Room with Conventional Glass Walls

Project Summary Conventional Glass Electrochromic Glass
Location and Weather
Project Project Name Project Name
Address
Calculation Time Sunday, December 13, 2020 13:00 PM Sunday, December 13, 2020 13:00 PM
Report Type Detailed Detailed
Latitude −6.18° −6.18°
Longitude 106.83° 106.83°
Summer Dry Bulb 33°C 33°C
Summer Wet Bulb 28°C 28°C
Winter Dry Bulb 22°C 22°C
Mean Daily Range 8°C 8°C

Results of Thermal Measurement in a Room with Electrochromic Glass Walls

Project Summary Electrochromic Glass Conventional Glass
Location and Weather
Project Project Name Project Name
Address
Calculation Time Sunday, December 13, 2020 13:00 PM Sunday, December 13, 2020 13:00 PM
Report Type Detailed Detailed
Latitude −6.18° −6.18°
Longitude 106.83° 106.83°
Summer Dry Bulb 33°C 33°C
Summer Wet Bulb 28°C 28°C
Winter Dry Bulb 22°C 22°C
Mean Daily Range 8°C 8°C

Results of Measurement of Thermal Load on Conventional Glass

Time Building type Room type Area Material Cooling Load Heating Load
Sunday, Dec 13, 2020, 13.00 University Room class 45 m2 Clear Glass 3,122 W −38 W

Results of Light Intensity Measurement in the Room

Nr. type of application natural lighting [lux]
1 With Double Skin Façade 352.7–25,764.7
2 Without Double Skin Façade 713–42,026.1

Results of Measurement of Thermal Load with Electrochromic Glass

Time Building type Room type Area Material Cooling Load Heating Load
Sunday, Dec 13, 2020, 13.00 University Room class 45 m2 Electrocromic glass, type sageglass climplus classicSR20 (Dark Tint) 2,289 W −2 W