Cite

TraczykWFizjologia człowieka w zarysiePZWL, Warszawajournal1992231237 Traczyk W Fizjologia człowieka w zarysie PZWL, Warszawa journal 1992 231 237 Search in Google Scholar

BamberJCosgroveDDietrichCFFromageauJBojungaJCalliadaFEFSUMB guidelines and recommendations on the clinical use of ultrasound elastographyPart 1: Basic principles and technology. Ultraschall Med201334169184 Bamber J Cosgrove D Dietrich CF Fromageau J Bojunga J Calliada F EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography Part 1: Basic principles and technology. Ultraschall Med 2013 34 169 184 Search in Google Scholar

OphirJCéspedesIPonnekantiHYazdiYLiXElastography: A quantitative method for imaging the elasticity of biological tissuesUltrason Imaging199113111134 Ophir J Céspedes I Ponnekanti H Yazdi Y Li X Elastography: A quantitative method for imaging the elasticity of biological tissues Ultrason Imaging 1991 13 111 134 10.1177/0161734691013002011858217 Search in Google Scholar

LeungVYShenJWongVWAbrigoJWongGLChimAMQuantitative elastography of liver fibrosis and spleen stiffness in chronic hepatitis B carriers: Comparison of shear-wave elastography and transient elastography with liver biopsy correlationRadiology2013269910918 Leung VY Shen J Wong VW Abrigo J Wong GL Chim AM Quantitative elastography of liver fibrosis and spleen stiffness in chronic hepatitis B carriers: Comparison of shear-wave elastography and transient elastography with liver biopsy correlation Radiology 2013 269 910 918 10.1148/radiol.1313012823912619 Search in Google Scholar

Zaleska-DorobiszUPawluśASzymańskaKŁaseckiMZiajkiewiczMUltrasound elastography: Review of techniques and its clinical applications in pediatricsPart 2. Adv Clin Exp Med201524725730 Zaleska-Dorobisz U Pawluś A Szymańska K Łasecki M Ziajkiewicz M Ultrasound elastography: Review of techniques and its clinical applications in pediatrics Part 2. Adv Clin Exp Med 2015 24 725 730 10.17219/acem/3458126469119 Search in Google Scholar

PorschMGörnerCWendlerJJLiehrUBLuxASiedentopfSElastografia fali poprzecznej nie pozwala na odróżnienie zmian w sterczu o charakterze złośliwym i łagodnym – analiza porównawcza wyników biopsji, badania histopatologicznego i elastografiiJ Ultrason201616348358 Porsch M Görner C Wendler JJ Liehr UB Lux A Siedentopf S Elastografia fali poprzecznej nie pozwala na odróżnienie zmian w sterczu o charakterze złośliwym i łagodnym – analiza porównawcza wyników biopsji, badania histopatologicznego i elastografii J Ultrason 2016 16 348 358 10.15557/JoU.2016.0035526952228138406 Search in Google Scholar

Dobruch-SobczakKRóżnicowanie charakteru litych zmian ogniskowych w piersiach w sonoelastografii kompresyjnejCzęść II: Ocena wartości diagnostycznej klasyfikacji BIRADS-usg, skali Tsukuba oraz wskaźnika FLR. J Ultrason2012133149 Dobruch-Sobczak K Różnicowanie charakteru litych zmian ogniskowych w piersiach w sonoelastografii kompresyjnej Część II: Ocena wartości diagnostycznej klasyfikacji BIRADS-usg, skali Tsukuba oraz wskaźnika FLR. J Ultrason 2012 13 31 49 Search in Google Scholar

PaluchŁNawrocka-LaskusEWieczorekJMrukBFrelMWaleckiJUse of ultrasound elastography in the assessment of the musculoskeletal systemPol J Radiol201681240246 Paluch Ł Nawrocka-Laskus E Wieczorek J Mruk B Frel M Walecki J Use of ultrasound elastography in the assessment of the musculoskeletal system Pol J Radiol 2016 81 240 246 10.12659/PJR.896099488031127279926 Search in Google Scholar

JędrzejwskiGWieczorekAPWieloparametryczna ultrasonografia w diagnostyce worka mosznowego i jąder niezstąpionych u chłopcówJ Ultrason201313425430 Jędrzejwski G Wieczorek AP Wieloparametryczna ultrasonografia w diagnostyce worka mosznowego i jąder niezstąpionych u chłopców J Ultrason 2013 13 425 430 10.15557/JoU.2013.0045457967426672775 Search in Google Scholar

CañasTFontanillaTMirallesMMaciáAMalalanaARománENormal values of spleen stiffness in healthy children assessed by acoustic radiation force impulse imaging (ARFI): Comparison between two ultrasound transducersPediatr Radiol20154513161322 Cañas T Fontanilla T Miralles M Maciá A Malalana A Román E Normal values of spleen stiffness in healthy children assessed by acoustic radiation force impulse imaging (ARFI): Comparison between two ultrasound transducers Pediatr Radiol 2015 45 1316 1322 10.1007/s00247-015-3306-z25796383 Search in Google Scholar

LeeMJKimMJHanKHYoonCSAge-related changes in liver, kidney, and spleen stiffness in healthy children measured with acoustic radiation force impulse imagingEur J Radiol201382e290e294 Lee MJ Kim MJ Han KH Yoon CS Age-related changes in liver, kidney, and spleen stiffness in healthy children measured with acoustic radiation force impulse imaging Eur J Radiol 2013 82 e290 e294 10.1016/j.ejrad.2013.01.01823433651 Search in Google Scholar

KarlasTLindnerFTröltzschMKeimVAssessment of spleen stiffness using acoustic radiation force impulse imaging (ARFI): Definition of examination standards and impact of breathing maneuversUltraschall Med2014353843 Karlas T Lindner F Tröltzsch M Keim V Assessment of spleen stiffness using acoustic radiation force impulse imaging (ARFI): Definition of examination standards and impact of breathing maneuvers Ultraschall Med 2014 35 38 43 10.1055/s-0033-135623024510458 Search in Google Scholar

ArdaKCiledagNAktasEAribasBKKöseKQuantitative assessment of normal soft-tissue elasticity using shear-wave ultrasound elastographyAJR Am J Roentgenol2011197532536 Arda K Ciledag N Aktas E Aribas BK Köse K Quantitative assessment of normal soft-tissue elasticity using shear-wave ultrasound elastography AJR Am J Roentgenol 2011 197 532 536 10.2214/AJR.10.544921862792 Search in Google Scholar

PawluśAInglotMSSzymańskaKKaczorowskiKMarkiewiczBDKaczorowskaAShear wave elastography of the spleen: evaluation of spleen stiffness in healthy volunteersAbdom Radiol (NY20164121692174 Pawluś A Inglot MS Szymańska K Kaczorowski K Markiewicz BD Kaczorowska A Shear wave elastography of the spleen: evaluation of spleen stiffness in healthy volunteers Abdom Radiol (NY 2016 41 2169 2174 10.1007/s00261-016-0834-4505941227389244 Search in Google Scholar

KjaergaardMThieleMMadsenBSJansenCTrebickaJKragAHigh risk of misclassifying liver stiffness using 2D shear-wave and transient elastography during a moderate or high calorie mealHepatology201562594A595A Kjaergaard M Thiele M Madsen BS Jansen C Trebicka J Krag A High risk of misclassifying liver stiffness using 2D shear-wave and transient elastography during a moderate or high calorie meal Hepatology 2015 62 594A 595A Search in Google Scholar

GallottiAD’OnofrioMPozzi MucelliRAcoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomenRadiol Med2010115889897 Gallotti A D’Onofrio M Pozzi Mucelli R Acoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomen Radiol Med 2010 115 889 897 10.1007/s11547-010-0504-520082227 Search in Google Scholar

BaréPHepatitis C virus and peripheral blood mononuclear cell reservoirs Patricia BaréWorld J Hepatol200916771 Baré P Hepatitis C virus and peripheral blood mononuclear cell reservoirs Patricia Baré World J Hepatol 2009 1 67 71 10.4254/wjh.v1.i1.67299926121160967 Search in Google Scholar

LaskusTRadkowskiMWangLFVargasHRakelaJSearch for hepatitis C virus extrahepatic replication sites in patients with acquired immunodeficiency syndrome: Specific detection of negative-strand viral RNA in various tissuesHepatology19982813981401 Laskus T Radkowski M Wang LF Vargas H Rakela J Search for hepatitis C virus extrahepatic replication sites in patients with acquired immunodeficiency syndrome: Specific detection of negative-strand viral RNA in various tissues Hepatology 1998 28 1398 1401 10.1002/hep.5102805319794927 Search in Google Scholar

Di BisceglieAMHoofnagleJHHepatitis B virus replication within the human spleenJ Clin Microbiol19902828502852 Di Bisceglie AM Hoofnagle JH Hepatitis B virus replication within the human spleen J Clin Microbiol 1990 28 2850 2852 10.1128/jcm.28.12.2850-2852.19902682942280024 Search in Google Scholar

TrovatoFMAtzoriSMusumeciGTooleyVMarcinkowskiHCrosseyMMLiver and spleen transient elastography and Acoustic Radiation Force Impulse MeasurementsPerformance and comparison of measurements in the same area concurrently assessed for liver fibrosis by biopsy. Adv Med Sci201560300306 Trovato FM Atzori S Musumeci G Tooley V Marcinkowski H Crossey MM Liver and spleen transient elastography and Acoustic Radiation Force Impulse Measurements Performance and comparison of measurements in the same area concurrently assessed for liver fibrosis by biopsy. Adv Med Sci 2015 60 300 306 Search in Google Scholar

RewishaEAElsabaawyMMAlsebaeyAElmazalyMATharwaESEvaluation of the role of liver and splenic transient elastography in chronic hepatitis C related fibrosisJ Liver Disease Transplant201653. Rewisha EA Elsabaawy MM Alsebaey A Elmazaly MA Tharwa ES Evaluation of the role of liver and splenic transient elastography in chronic hepatitis C related fibrosis J Liver Disease Transplant 2016 5 3 10.4172/2325-9612.1000142 Search in Google Scholar

GiuntaMConteDFraquelliMRole of spleen elastography in patients with chronic liver diseasesWorld J Gastroenterol20162278577867 Giunta M Conte D Fraquelli M Role of spleen elastography in patients with chronic liver diseases World J Gastroenterol 2016 22 7857 7867 10.3748/wjg.v22.i35.7857502880227672283 Search in Google Scholar

GrgurevicIPuljizZBrnicDBokunTHeinzlRLukicALiver and spleen stiffness and their ratio assessed by real-time two dimensional-shear wave elastography in patients with liver fibrosis and cirrhosis due to chronic viral hepatitisEur Radiol20152532143221 Grgurevic I Puljiz Z Brnic D Bokun T Heinzl R Lukic A Liver and spleen stiffness and their ratio assessed by real-time two dimensional-shear wave elastography in patients with liver fibrosis and cirrhosis due to chronic viral hepatitis Eur Radiol 2015 25 3214 3221 10.1007/s00330-015-3728-x25903706 Search in Google Scholar

YeXPRanHTChengJZhuYFZhangDZZhangPLiver and spleen stiffness measured by acoustic radiation force impulse elastography for noninvasive assessment of liver fibrosis and esophageal varices in patients with chronic hepatitis BJ Ultrasound Med20123112451253 Ye XP Ran HT Cheng J Zhu YF Zhang DZ Zhang P Liver and spleen stiffness measured by acoustic radiation force impulse elastography for noninvasive assessment of liver fibrosis and esophageal varices in patients with chronic hepatitis B J Ultrasound Med 2012 31 1245 1253 10.7863/jum.2012.31.8.124522837289 Search in Google Scholar

PawluśAInglotMChabowskiMSzymańskaKInglotMPatykMShear wave elastography (SWE) of the spleen in patients with hepatitis B and C but without significant liver fibrosisBr J Radiol20168920160423. Pawluś A Inglot M Chabowski M Szymańska K Inglot M Patyk M Shear wave elastography (SWE) of the spleen in patients with hepatitis B and C but without significant liver fibrosis Br J Radiol 2016 89 20160423. 10.1259/bjr.20160423512480827529729 Search in Google Scholar

JansenCBogsCVerlindenWThieleMMöllerPGörtzenJShear-wave elastography of the liver and spleen identifies clinically significant portal hypertension: A prospective multicentre studyLiver Int201737396405 Jansen C Bogs C Verlinden W Thiele M Möller P Görtzen J Shear-wave elastography of the liver and spleen identifies clinically significant portal hypertension: A prospective multicentre study Liver Int 2017 37 396 405 10.1111/liv.13243 Search in Google Scholar

MaXWangLWuHFengYHanXBuHSpleen stiffness is superior to liver stiffness for predicting esophageal varices in chronic liver disease: A meta-analysisPLoS ONE201611e0165786 Ma X Wang L Wu H Feng Y Han X Bu H Spleen stiffness is superior to liver stiffness for predicting esophageal varices in chronic liver disease: A meta-analysis PLoS ONE 2016 11 37 41 10.1371/journal.pone.0165786 Search in Google Scholar

RosselliMRoccarinaDPatchDSekharMMajumdarAO’BeirneJPoint shear wave elastography (ElastPQ) is a reliable non-invasive tool for the diagnosis and characterisation of portal hypertensionJ Hepatol201766S667. Rosselli M Roccarina D Patch D Sekhar M Majumdar A O’Beirne J Point shear wave elastography (ElastPQ) is a reliable non-invasive tool for the diagnosis and characterisation of portal hypertension J Hepatol 2017 66 S667. 10.1016/S0168-8278(17)31803-2 Search in Google Scholar

ZykusRJonaitisLPetrenkienėVPranculisAKupčinskasLLiver and spleen transient elastography predicts portal hypertension in patients with chronic liver disease: A prospective cohort studyBMC Gastroenterol201515183 Zykus R Jonaitis L Petrenkienė V Pranculis A Kupčinskas L Liver and spleen transient elastography predicts portal hypertension in patients with chronic liver disease: A prospective cohort study BMC Gastroenterol 2015 15 183 10.1186/s12876-015-0414-z469024326702818 Search in Google Scholar

ColecchiaAMontroneLScaioliEBacchi-ReggianiMLColliACasazzaGMeasurement of spleen stiffness to evaluate portal hypertension and the presence of esophageal varices in patients with HCV-related cirrhosisGastroenterology2012143646654 Colecchia A Montrone L Scaioli E Bacchi-Reggiani ML Colli A Casazza G Measurement of spleen stiffness to evaluate portal hypertension and the presence of esophageal varices in patients with HCV-related cirrhosis Gastroenterology 2012 143 646 654 10.1053/j.gastro.2012.05.03522643348 Search in Google Scholar

HirookaMOchiHKoizumiYKisakaYAbeMIkedaYSplenic elasticity measured with real-time tissue elastography is a marker of portal hypertensionRadiology2011261960968 Hirooka M Ochi H Koizumi Y Kisaka Y Abe M Ikeda Y Splenic elasticity measured with real-time tissue elastography is a marker of portal hypertension Radiology 2011 261 960 968 10.1148/radiol.1111015621926379 Search in Google Scholar

CalvarusoVBronteFConteESimoneFCraxìADi MarcoVModified spleen stiffness measurement by transient elastography is associated with presence of large oesophageal varices in patients with compensated hepatitis C virus cirrhosisJ Viral Hepat201320867874 Calvaruso V Bronte F Conte E Simone F Craxì A Di Marco V Modified spleen stiffness measurement by transient elastography is associated with presence of large oesophageal varices in patients with compensated hepatitis C virus cirrhosis J Viral Hepat 2013 20 867 874 10.1111/jvh.1211424304456 Search in Google Scholar

ParkJKwonHChoJOhJLeeSHanSIs the spleen stiffness value acquired using acoustic radiation force impulse (ARFI) technology predictive of the presence of esophageal varices in patients with cirrhosis of various etiologies?Med Ultrason2016181117 Park J Kwon H Cho J Oh J Lee S Han S Is the spleen stiffness value acquired using acoustic radiation force impulse (ARFI) technology predictive of the presence of esophageal varices in patients with cirrhosis of various etiologies? Med Ultrason 2016 18 11 17 10.11152/mu.2013.2066.181.sf Search in Google Scholar

CassinottoCCharrieAMouriesALapuyadeBHiriartJBVergniolJLiver and spleen elastography using supersonic shear imaging for the non-invasive diagnosis of cirrhosis severity and oesophageal varicesDig Liver Dis201547695701 Cassinotto C Charrie A Mouries A Lapuyade B Hiriart JB Vergniol J Liver and spleen elastography using supersonic shear imaging for the non-invasive diagnosis of cirrhosis severity and oesophageal varices Dig Liver Dis 2015 47 695 701 10.1016/j.dld.2015.04.00825959234 Search in Google Scholar

AbdelbaryMSKamalSAlbuhairiAKhairyAZayedNYosryAPTU- 075 liver and spleen stiffness measurements based on acoustic radiation force impulse elastography for noninvasive assessment of esophageal varices in HCV-related advanced fibrosisGut201665A89A90 Abdelbary MS Kamal S Albuhairi A Khairy A Zayed N Yosry A PTU- 075 liver and spleen stiffness measurements based on acoustic radiation force impulse elastography for noninvasive assessment of esophageal varices in HCV-related advanced fibrosis Gut 2016 65 A89 A90 10.1136/gutjnl-2016-312388.160 Search in Google Scholar

BüchterMKahramanAMankaPGerkenGJochumCCanbayASpleen and liver stiffness is positively correlated with the risk of esophageal variceal bleedingDigestion201694138144 Büchter M Kahraman A Manka P Gerken G Jochum C Canbay A Spleen and liver stiffness is positively correlated with the risk of esophageal variceal bleeding Digestion 2016 94 138 144 10.1159/00045070427756066 Search in Google Scholar

BüchterMKahramanAMankaPCanbayAGerkenGJochumCSpleen and liver stiffness measurement using transient elastography correlates well with hypertensive upper gastrointestinal bleeding risk – an evaluation of 143 patientsZ Gastroenterol201553A2A42 Büchter M Kahraman A Manka P Canbay A Gerken G Jochum C Spleen and liver stiffness measurement using transient elastography correlates well with hypertensive upper gastrointestinal bleeding risk – an evaluation of 143 patients Z Gastroenterol 2015 53 A2 A42 10.1055/s-0035-1568014 Search in Google Scholar

UchidaHSakamotoSKobayashiMShigetaTMatsunamiMSasakiKThe degree of spleen stiffness measured on acoustic radiation force impulse elastography predicts the severity of portal hypertension in patients with biliary atresia after portoenterostomyJ Pediatr Surg201550559564 Uchida H Sakamoto S Kobayashi M Shigeta T Matsunami M Sasaki K The degree of spleen stiffness measured on acoustic radiation force impulse elastography predicts the severity of portal hypertension in patients with biliary atresia after portoenterostomy J Pediatr Surg 2015 50 559 564 10.1016/j.jpedsurg.2014.12.02625840063 Search in Google Scholar

WebbMShiboletOHalpernZNagarMAmariglioNLevitSAssessment of liver and spleen stiffness in patients with myelofibrosis using FibroScan and shear wave elastographyUltrasound Q201531166169 Webb M Shibolet O Halpern Z Nagar M Amariglio N Levit S Assessment of liver and spleen stiffness in patients with myelofibrosis using FibroScan and shear wave elastography Ultrasound Q 2015 31 166 169 10.1097/RUQ.000000000000013926366688 Search in Google Scholar

IurloACattaneoDGiuntaMGianelliUConsonniDFraquelliMTransient elastography spleen stiffness measurements in primary myelofibrosis patients: A pilot study in a single centreBr J Haematol2015170890892 Iurlo A Cattaneo D Giunta M Gianelli U Consonni D Fraquelli M Transient elastography spleen stiffness measurements in primary myelofibrosis patients: A pilot study in a single centre Br J Haematol 2015 170 890 892 10.1111/bjh.1334325753891 Search in Google Scholar

GaoJZhengXZhengYYZuoGQRanHTAuhYHShear wave elastography of the spleen for monitoring transjugular intrahepatic portosystemic shunt function: A pilot studyJ Ultrasound Med201635951958 Gao J Zheng X Zheng YY Zuo GQ Ran HT Auh YH Shear wave elastography of the spleen for monitoring transjugular intrahepatic portosystemic shunt function: A pilot study J Ultrasound Med 2016 35 951 958 10.7863/ultra.15.0700927036168 Search in Google Scholar

eISSN:
2451-070X
Idioma:
Inglés
Calendario de la edición:
4 veces al año
Temas de la revista:
Medicine, Basic Medical Science, other