Cite

[1] Braun, J., Perera, S., Gosbell, V. (2005). Design of light chamber for the characterisation of flicker behavior of lamps. In Australasian Universities Power Engineering Conference, Hobart, Australia, 1–6.Search in Google Scholar

[2] Chen, S., Heah, M.Y., Then, A.B., Foo, M.K. (2008). Automatic evaluation of flickering sensitivity of fluorescent lamps caused by interharmonic voltages. In XIII International Conference on Harmonics and Quality of Power, Wollongong, Australia, 1–6.10.1109/ICHQP.2008.4668775Search in Google Scholar

[3] Drapela, J., Kratky, M., Weidinger, L., Zavodny, M. (2005). Light flicker of fluorescent lamps with different types of ballasts caused by interharmonics. In 2005 IEEE Russia Power Tech, St. Petersburg, Russia, 1–7.10.1109/PTC.2005.4524419Search in Google Scholar

[4] International Electrotechnical Commission. (2016). Voltage fluctuation. IEV number 161-08-05. http://www.electropedia.org.Search in Google Scholar

[5] International Electrotechnical Commission. (2010). Testing and measurement techniques – Flickermeter – Functional and design specifications. IEC 61000-4-15:2010.Search in Google Scholar

[6] Aoki, M. (1980). Standard method for measurement of voltage fluctuations. In 9th International Congress UIE, Cannes, France, 3–12.Search in Google Scholar

[7] Hong, Y.-Y., Lee, L.-H. (1999). Analysis of equivalent 10 Hz voltage flicker in power systems. IEE Proceedings - Generation, Transmission and Distribution, 146 (5), 447–452.10.1049/ip-gtd:19990362Search in Google Scholar

[8] Wiczyński, G. (2017). Model of DV10-meter signal chain for periodic voltage fluctuation. Measurement, 93, 224–231.10.1016/j.measurement.2016.07.010Search in Google Scholar

[9] Owen, E.L. (1994). Power disturbance and power quality – light flicker voltage requirements. In Conference Record of the 1994 IEEE Industry Applications Society Annual Meeting, Denver, USA, Vol. 3, 2303–2309.10.1109/IAS.1994.377752Search in Google Scholar

[10] Wiczyński, G. (2017). Estimation of Pst indicator values on the basis of voltage fluctuation indices. IEEE Transactions on Instrumentation and Measurement, 66 (8), 2046–2055.10.1109/TIM.2017.2687538Search in Google Scholar

[11] Otomański, P, Wiczyński, G. (2011). The usage of voltage and current fluctuation for localization of disturbing loads supplied from power grid. Przegląd Elektrotechniczny, 87 (1), 107–111.Search in Google Scholar

[12] International Electrotechnical Commission. (2016). Flicker, IEV number 845-02-49. http://www.electropedia.org.Search in Google Scholar

[13] Lehman, B., Wilkins, A.J. (2014). Designing to mitigate effects of flicker in LED lighting: Reducing risks to health and safety. IEEE Power Electronics Magazine, 1 (3), 18–26.10.1109/MPEL.2014.2330442Search in Google Scholar

[14] Howarth, P., Heron, G., Greenhouse, D.S., Bailey, I.L., Berman, S.M. (1993). Discomfort from glare: The role of pupillary hippus. Lighting Research & Technology, 25 (1), 37–42.10.1177/096032719302500106Search in Google Scholar

[15] Peretto, L., Rovati, L., Salvatori, G., Tinarelli, R., Emanuel, A.E. (2007). A measurement system for the analysis of the response of the human eye to the light flicker. IEEE Transactions on Instrumentation and Measurement, 56 (4), 1384–1390.10.1109/TIM.2007.899855Open DOISearch in Google Scholar

[16] Stone, P.T. (2009). A model for the explanation of discomfort and pain in the eye caused by light. Lighting Research & Technology, 41 (2), 109–121.10.1177/1477153509102344Search in Google Scholar

[17] Emanuel, A.E., Peretto, L. (2004). A simple lamp-eye-brain model for flicker observations. IEEE Transactions on Power Delivery, 19 (4), 1308–1313.10.1109/TPWRD.2004.829930Open DOISearch in Google Scholar

[18] Peretto, L., Emanuel, A.E. (1997). A theoretical study of the incandescent filament lamp performance under voltage flicker. IEEE Transactions on Power Delivery, 12 (1), 279–288.10.1109/61.568251Open DOISearch in Google Scholar

[19] Peretto, L., Pivello, E., Tinarelli, R., Emanuel, A.E. (2007). Theoretical analysis of the physiologic mechanism of luminous variation in eye-brain system. IEEE Transactions on Instrumentation and Measurement, 56 (1), 164–170.10.1109/TIM.2006.887223Search in Google Scholar

[20] Masi, M.G., Peretto, L., Tinarelli, R., Rovati, L. (2008). Modeling of the physiological behavior of human vision system under flicker condition. In XIII International Conference on Harmonics and Quality of Power, Wollongong, Australia, 1–6.10.1109/ICHQP.2008.4668824Search in Google Scholar

[21] Musiał, E. (2005). Podstawowe pojȩcia techniki oświetleniowej. Biuletyn SEP INPE, 75. (in Polish)Search in Google Scholar

[22] Kim, C.B., Mayer, M.J. (1994). Foveal flicker sensitivity in healthy aging eyes. II. Cross-sectional aging trends from 18 through 77 years of age. Journal of the Optical Society of America, 11 (7), 1958–1969.Search in Google Scholar

[23] Rashbass, C. (1970). The visibility of transient changes of luminance. Journal of Physiology, 210 (1), 165–186.10.1113/jphysiol.1970.sp00920213956555500775Search in Google Scholar

[24] Sokol, S., Tiggs, L.A. (1971). Electrical and psychophysical responses of the human visual system to periodic variation of luminance. Investigative Ophthalmology, 10 (3), 171–180.Search in Google Scholar

[25] Wilkins, A., Veitch, J., Lehman, B. (2010). LED lighting flicker and potential health concerns: IEEE standard PAR1789 update. In IEEE Energy Conversion Congress and Exposition, Atlanta, USA, 171–178.10.1109/ECCE.2010.5618050Search in Google Scholar

[26] Peretto, L., Riva, C.E., Rovati, L., Salvatori, G., Tinarelli, R. (2009). Analysis of the effects of flicker on the blood-flow variation in the human eye. IEEE Transactions on Instrumentation and Measurement, 58 (9), 2916–2922.10.1109/TIM.2009.2016773Open DOISearch in Google Scholar

[27] Cai, R., Cobben, J., Myrzik, J., Blom, J., Kling, W. (2008). New flicker weighting curves for different lamp types based on the lamp light spectrum. In XIII International Conference on Harmonics and Quality of Power, Wollongong, Australia, 1–6.Search in Google Scholar

[28] Walker, M. (1979). Electric utility flicker limitations. IEEE Transactions on Industry Applications, IA-15 (6), 644–655.10.1109/TIA.1979.4503725Open DOISearch in Google Scholar

[29] Culham, J.C., Kline, D.W. (2002). The age deficit on photopic counterphase flicker: Contrast, spatial frequency, and luminance effects. Canadian Journal of Experimental Psychology, 56 (3), 177–186.10.1037/h008739512271748Open DOISearch in Google Scholar

[30] Gallo, D., Landi, C., Pasquino, N. (2006). Design and calibration of an objective flickermeter. IEEE Transactions on Instrumentation and Measurement, 55 (6), 2118–2125.10.1109/TIM.2006.887122Open DOISearch in Google Scholar

[31] Gallo, D., Landi, C., Pasquino, N. (2004). An instrument for objective measurement of light flicker. Measurement, 41 (3), 334–340.Search in Google Scholar

[32] Cai, R., Cobben, J., Myrzik, J., Blom, J., Kling, W. (2009). Flicker responses of different lamp types. IET Generation, Transmission & Distribution, 3 (9), 816–824.10.1049/iet-gtd.2008.0429Search in Google Scholar

[33] Cai, R. (2009). Working out a model and an analysis of metrological properties of a digital flickermeter. Ph.D. dissertation, Eindhoven University of Technology, Eindhoven, Netherlands.Search in Google Scholar

[34] Shareef, H., Mohamed, A., Mohamed, K. (2010). Sensitivity of compact fluorescent lamps during voltage sags: An experimental investigation. WSEAS Transactions on Power Systems, 1 (5), 22–31.Search in Google Scholar

[35] Masi, M.G., Peretto, L., Tinarelli, R., Rovati, L. (2011). Assessment of human annoyance under flicker condition. In 2011 IEEE Instrumentation and Measurement Technology Conference, Binjiang, China, 1–5.10.1109/IMTC.2011.5944241Search in Google Scholar

[36] Chmielowiec, K. (2011). Flicker effect on different types of light sources. In 11th International Conference on Electrical Power Quality and Utilisation, Lisbon, Portugal, 1–6.10.1109/EPQU.2011.6128852Search in Google Scholar

[37] Azcarate, I., Gutierrez, J., Saiz, P., Lazkano, A., Leturiondo, L., Redondo, K. (2014). Flicker characteristics of efficient lighting assessed by the IEC flickermeter. Electric Power Systems Research, 107, 21–27.10.1016/j.epsr.2013.09.005Search in Google Scholar

[38] Azcarate, I., Gutierrez, J., Lazkano, A., Saiz, P., Redondo, K., Leturiondo, L. (2014). Experimental study of the response of efficient lighting technologies to complex voltage fluctuations. Electrical Power and Energy Systems, 63, 499–506.10.1016/j.ijepes.2014.06.039Search in Google Scholar

[39] International Electrotechnical Commission. (2015). Testing and measurement techniques – Power Quality Measurement Methods. IEC 61000-4-30:2015.Search in Google Scholar

[40] de Lange Dzn, H. (1958). Research into the dynamic nature of the human fovea - cortex systems with intermittent and modulated light. II. Phase shift in brightness and delay in color perception. Journal of the Optical Society of America, 48 (11), 784–789.Search in Google Scholar

[41] Kelly, D.H. (1961). Visual responses to time-dependent stimuli. I. Amplitude sensitivity measurements. Journal of the Optical Society of America, 51 (4), 422–429.10.1364/JOSA.51.000422Open DOISearch in Google Scholar

[42] Andersson, N., Sandstrom, M., Berglund, A., Hansson, K. (1994). Amplitude modulation of light various sources. Lighting Research and Technology, 26 (3), 157–160.10.1177/096032719402600305Search in Google Scholar

[43] Veitch, J.A., McColl, S.L. (1995). Modulation of fluorescent light: Flicker rate and light source effects on visual performance and visual comfort. Lighting Research and Technology, 27 (4), 243–256.10.1177/14771535950270040301Search in Google Scholar

[44] Carrillo, C., Cidrás, J. (2001). Fluorescent lamp modelling for voltage fluctuations. European Transactions on Electrical Power, 11 (2), 119–127.10.1002/etep.4450110206Open DOISearch in Google Scholar

[45] Gomez, J., Morcos, M. (2002). Flicker measurement and light effect. IEEE Power Engineering Review, 22 (11), 11–15.10.1109/MPER.2002.1045556Open DOISearch in Google Scholar

[46] Rong, C., Cobben, J.F.G., Myrzik, J.M.A., Blom, J.H., Kling, W.L. (2007). Flickermeter used for different types of lamps. In 9th International Conference on Electrical Power Quality and Utilisation, Barcelona, Spain, 1–6.10.1109/EPQU.2007.4424241Search in Google Scholar

[47] Manana, M., Ortiz, A., Renedo, C., Perez, S., Delgado, F., Azcondo, F.J., Diaz, F.J., Branas, C., Casanueva, R. (2007). Comparison of flicker sensitivity in HPS lamps. In International Symposium on Industrial Electronics, Vigo, Spain, 3002–3007.10.1109/ISIE.2007.4375093Search in Google Scholar

[48] Wie, Z., Watson, N.R., Frater, L.P. (2008). Modelling of compact fluorescent lamps. In XIII International Conference on Harmonics and Quality of Power, Wollongong, Australia, 1–6.Search in Google Scholar

[49] Kim, T., Rylander, M., Powers, E.J., Grady, W.M., Arapostathis, A. (2008). LED lamp flicker caused by interharmonics. In IEEE International Instrumentation and Measurement Technology Conference, Victoria, Canada, 1–6.10.1109/IMTC.2008.4547361Search in Google Scholar

[50] Koponen, P, Hansen, H., Bollen, M. (2015). Interharmonics and light flicker. In 23rd International Conference on Electricity Distribution, Lyon, France, 1/5–5/5.Search in Google Scholar

[51] Wang, C. (2008). Flicker-insensitive light dimmer for incandescent lamps. IEEE Transactions on Industrial Electronics, 55 (2), 767–772.10.1109/TIE.2007.908528Open DOISearch in Google Scholar

[52] Sharma, H., Sharp, F., McGranaghan, M. (2013). Flicker voltage fluctuation response of modern lamps including those with dimmable capability and other low voltage sensitive equipment. In 22nd International Conference on Electricity Distribution, Stockholm, Sweden, 1–4.10.1049/cp.2013.0726Search in Google Scholar

[53] Wiczyński, G. (2008). Sectional approximation of the flickermeter transformation characteristic for a sinusoidal modulating signal. IEEE Transactions on Instrumentation and Measurement, 57 (10), 2355–2363.10.1109/TIM.2008.922088Search in Google Scholar

[54] Agilent Technologies, Inc. (2012). Agilent 33500 Series Waveform Generator - Operating and Service Guide.Search in Google Scholar

[55] Chroma ATE Inc. (2004). Programmable AC Source 61501/61502/61503/61504 User’s Manual.Search in Google Scholar

[56] Uddin, S., Shareef, H., Mohamed, A. (2013). Power quality performance of energy-efficient low-wattage LED lamps. Measurement, 46 (10), 3783-3795.10.1016/j.measurement.2013.07.022Search in Google Scholar

[57] Zhang, R., Chung, H.S. (2014). A triac-dimmable LED lamp driver with wide dimming range. IEEE Transactions on Power Delivery, 29 (3), 1434–1446.10.1109/TPEL.2013.2263935Open DOISearch in Google Scholar

[58] Shrivastava, A., Singh, B., Pal, S. (2015). A novel wallswitched step-dimming concept in LED lighting systems using PFC zeta converter. IEEE Transactions on Industrial Electronics, 62 (10), 6272–628310.1109/TIE.2015.2416338Search in Google Scholar

eISSN:
1335-8871
Idioma:
Inglés
Calendario de la edición:
6 veces al año
Temas de la revista:
Engineering, Electrical Engineering, Control Engineering, Metrology and Testing