Determination of Maximum Horizontal Distance (XMHD) Travelled by Landfill Leachate from Lapite Dumpsite in Ibadan, Southwestern Nigeria
y
23 oct 2017
Acerca de este artículo
Publicado en línea: 23 oct 2017
Páginas: 18 - 29
Recibido: 23 mar 2017
Aceptado: 14 sept 2017
DOI: https://doi.org/10.1515/awutp-2016-0004
Palabras clave
© 2016 Olatunde I. Popoola et al., published by De Gruyter Open
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.
This study was designed to determine Maximum Horizontal Distance (XMHD) travelled by landfill leachate. Twenty - nine Schlumberger Vertical Electrical Soundings (VES) were conducted at 10.0m intervals away from four sides A, B, C and D of Lapite dumpsite. One VES point conducted outside the vicinity of the dumpsite served as a control. VES data were processed. Lowest resistivity values (Y) of VES points and the control point (Yc) were extracted. Curves of Y against X fitted best to yield an equation. XMHD was determined from the generated equation when Y = Yc. The determined (XMHD) on the four sides ranged from78.95m to 179.86m.