Uneingeschränkter Zugang

The Usefulness of Biosynthetic Vascular Graft Omniflow II and Autologous Veins for the Treatment of Massive Infection of Dacron Vascular Graft with Enterococcus faecalis HLAR


Zitieren

Infections of vascular grafts are the most severe complications in vascular surgery. We present the case of a 73-year-old male with infection of a dacron prosthesis with a strain of Enterococcus faecalis. The patient was treated with replacement of a full prosthesis with a combined graft constructed from Biosynthetic Vascular graft Omniflow and autologous veins. This graft is recommended for implantation in patients with a higher risk of infection. Our case is one of the first reported usage of this kind of graft in the aortic region and in a 2 years observation period no recurrence of infection was observed.

eISSN:
2544-4646
Sprache:
Englisch
Zeitrahmen der Veröffentlichung:
4 Hefte pro Jahr
Fachgebiete der Zeitschrift:
Biologie, Mikrobiologie und Virologie