Research on the failure behavior of cement- and fiber-reinforced sand under triaxial tensile loads
und
14. Aug. 2025
Über diesen Artikel
Artikel-Kategorie: Research Article
Online veröffentlicht: 14. Aug. 2025
Seitenbereich: 27 - 45
Eingereicht: 12. Nov. 2024
Akzeptiert: 28. Apr. 2025
DOI: https://doi.org/10.2478/sgem-2025-0018
Schlüsselwörter
© 2025 Hysen Ahmeti and Ragip Behrami, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Figure 7

Figure 8

Figure 9

Figure 10

Figure 11

Figure 12

Figure 13

Figure 14

Figure 15

Figure 16

Figure 17

Summary of triaxial direct tension test results in the present study_
CC | FC | TF | CPa | Devatoric stress (kPa) | Mean stress (kPa) | Volumetric strain (%) | Axial state (%) | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
At failure | Residual state | At failure | Residual state | At failure | Residual state | At failure | Residual state | ||||
3 | 0 | — | 100 | −196 | −104 | 35 | 65 | −0.037 | −0.45 | −0.41 | −1.07 |
3 | 0 | — | 200 | −277 | −191 | 108 | 136 | 0.035 | −0.86 | −0.45 | −1.32 |
3 | 0 | — | 300 | −365 | −278 | 178 | 207 | 0.029 | −0.22 | −0.49 | −0.89 |
3 | 0 | — | 300 | −364 | −282 | 179 | 206 | 0.060 | −0.10 | −0.46 | −0.73 |
3 | 0.5 | I | 100 | −172 | −160 | 43 | 47 | −0.601 | −1.61 | −0.61 | −0.51 |
3 | 0.5 | I | 200 | −258 | −240 | 114 | 120 | −0.303 | −1.21 | −0.66 | −2.18 |
3 | 0.5 | I | 300 | −311 | −293 | 196 | 202 | −0.031 | −1.35 | −1.00 | −3.26 |
3 | 0.5 | I | 200 | −245 | −222 | 118 | 126 | −0.330 | −1.45 | −0.77 | −2.33 |
3 | 0.5 | — | 100 | −148 | −123 | 51 | 59 | −1.800 | −1.80 | −1.40 | −4.50 |
3 | 0.5 | — | 200 | −239 | −192 | 120 | 136 | −1.050 | −1.43 | −2.06 | −4.39 |
3 | 0.5 | — | 300 | −320 | −292 | 193 | 203 | −1.190 | −1.60 | −2.51 | −1.76 |
5 | 0 | — | 100 | −211 | −95 | 30 | 68 | −0.229 | −0. 66 | −0.58 | −1.01 |
5 | 0 | — | 200 | −346 | −164 | 85 | 145 | −0.100 | −0.63 | −0.44 | −1.25 |
5 | 0 | — | 300 | −431 | −240 | 156 | 220 | −0.050 | −0.53 | −0.56 | 1.46 |
5 | 0 | — | 200 | −316 | −172 | 95 | 143 | −0.090 | −0.43 | −0.42 | −1.22 |
5 | 0 | — | 300 | −450 | −232 | 150 | 223 | −0.050 | −0.33 | −0.56 | −1.47 |
5 | 0.5 | I | 100 | −186 | −165 | 38 | 45 | 0.110 | −1.62 | −0.55 | −3.02 |
5 | 0.5 | I | 200 | −333 | −313 | 89 | 96 | 0.120 | −0.99 | −0.38 | −3.03 |
5 | 0.5 | I | 300 | −406 | −369 | 165 | 177 | 0.110 | −1.06 | −0.70 | −5.54 |
5 | 0.5 | II | 100 | −191 | −157 | 36 | 48 | −2.160 | −2.68 | −0.68 | −9.97 |
5 | 0.5 | II | 200 | −299 | −267 | 100 | 111 | −1.860 | −2.00 | −05.86 | −11.56 |
5 | 0.5 | II | 300 | −364 | −328 | 179 | 191 | −0.900 | −1.80 | −8.89 | −12.09 |
5 | 0.5 | II | 200 | −322 | −256 | 93 | 115 | −2.150 | −3.10 | −4.77 | −7.20 |
Physical properties of the fiber_
Typing | Fiber type I | Fiber type II |
---|---|---|
Material | Micro-synthetic | Macro-synthetic |
Tensile strength | 4,000,000 | 570,000–660,000 kPa |
Diameter | 23 μm | 300 μm |
Aspect ratio | 600–1,200 | 30–120 |
Number per kg | <100,000,000 | 53,800 |
Color | Glossy | Gray |
Summary of uniaxial tensile strength test results in the present study_
CCa | FCb | TFc |
|
---|---|---|---|
3 | 0 | — | 44 |
3 | 0.5 | I | 41 |
3 | 0.5 | II | 39 |
5 | 0 | — | 104 |
5 | 0.5 | I | 95 |
5 | 0.5 | II | 90 |
Physical properties of the cement object_
Object | Range | |
---|---|---|
Autoclave | 0.2 | |
Blian | ||
Setting time (min) | ||
Initial | 120 | |
Final | 180 | |
Compressive strength (MPa) | ||
3 days | 220 | |
7 days | 320 | |
28 days | 400 |