Login
Registrieren
Passwort zurücksetzen
Veröffentlichen & Verteilen
Verlagslösungen
Vertriebslösungen
Themen
Allgemein
Altertumswissenschaften
Architektur und Design
Bibliotheks- und Informationswissenschaft, Buchwissenschaft
Biologie
Chemie
Geowissenschaften
Geschichte
Industrielle Chemie
Informatik
Jüdische Studien
Kulturwissenschaften
Kunst
Linguistik und Semiotik
Literaturwissenschaft
Materialwissenschaft
Mathematik
Medizin
Musik
Pharmazie
Philosophie
Physik
Rechtswissenschaften
Sozialwissenschaften
Sport und Freizeit
Technik
Theologie und Religion
Wirtschaftswissenschaften
Veröffentlichungen
Zeitschriften
Bücher
Konferenzberichte
Verlage
Blog
Kontakt
Suche
EUR
USD
GBP
Deutsch
English
Deutsch
Polski
Español
Français
Italiano
Warenkorb
Home
Zeitschriften
Journal of Electrical Bioimpedance
Band 9 (2018): Heft 1 (January 2018)
Uneingeschränkter Zugang
Applications of bioimpedance measurement techniques in tissue engineering
M. Amini
M. Amini
,
J. Hisdal
J. Hisdal
und
H. Kalvøy
H. Kalvøy
| 31. Dez. 2018
Journal of Electrical Bioimpedance
Band 9 (2018): Heft 1 (January 2018)
Über diesen Artikel
Vorheriger Artikel
Nächster Artikel
Zusammenfassung
Artikel
Figuren und Tabellen
Referenzen
Autoren
Artikel in dieser Ausgabe
Vorschau
PDF
Zitieren
Teilen
Article Category:
Review Article
Online veröffentlicht:
31. Dez. 2018
Seitenbereich:
142 - 158
Eingereicht:
14. Dez. 2018
DOI:
https://doi.org/10.2478/joeb-2018-0019
Schlüsselwörter
Tissue Engineering
,
Bioimpedance Measurement
,
Non-invasive monitoring
© 2018 M. Amini, J. Hisdal, H. Kalvøy published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Figure 1
Flow of electrical current through biological tissue: A) At lower frequencies, current flows between the cells and through the extracellular fluid, B) At high frequencies, current penetrates the cell membranes and flows through intracellular and extracellular fluid.
Figure 2
Schematic of a two electrode configuration set up, where both electrodes are used for current carrying (CC) and voltage pick up (PU).
Figure 3
Schematic of a three electrode configuration set up, where an external voltage is applied between the reference (RE) and the working electrode (WE), and electric current is passed from the counter electrode (CE) to the working electrode (WE).
Figure 4
Schematic of a four electrode configuration set up. CC1 and CC2 are the current carrying electrodes while PU1 and PU2 are the voltage pick up electrodes.
Figure 5
Schematic representation of the 2D cell culture where cells are seeded as individual cell into a cell culture dish.
Figure 6
Schematic representation of a scaffold free 3D cell culture in the form of spheroids.
Figure 7
A) Organ on chip device showing an extra cellular matrix (ECM) coated flexible porous membrane with epithelial cells through the middle of the central microchannel and vacuum chambers on both sides; B) Picture of the organ on a chip device (directions indicated by arrows visualize perfusion of the red and blue dyes). Copied with permission (78).
Figure 8
A schematic drawing of an Electric Cell Substrate Impedance Sensing system (ECIS): The insulating membranes of the cells attached to the sensing electrode, cause capacitance (C) by constraining the current and force the current to flow beneath and between the cells which causes resistance (R), therefore in ECIS both the capacitance and resistance contribute to the measured impedance
Figure 9
Schematic of Trans Endothelial Electrical Resistance (TEER) measurement system with chopstick electrodes.
Figure 10
Impedance data collection methods in Electrical Impedance Tomography by applying 16 equally spaced electrodes: A) Adjacent Drive or Neighboring method, B) Opposite method.