LCF fatigue test matrix_
Temperature, T (°C) | 500 | Hold time, th (s) | Frequency, (Hz) | Total strain, Δ |
Strain ratio, |
-1 | |||
Cycle scheme | ||||
0 | 0.08 | 0.4 | ||
0.6 | ||||
120 | 0.008 | 0.4 | ||
0.6 |
Steel G17CrMoV5-10 chemical composition for cast_
Element | C | Si | Mn | P | S | Ni | Cr | Mo | V | Cu | Sn |
---|---|---|---|---|---|---|---|---|---|---|---|
wt.% | 0.19 | 0.4 | 0.9 | 0.014 | 0.011 | 0.08 | 1.44 | 1.04 | 0.2 | 0.30 | 0.001 |